<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet type="text/xsl" href="mpls-oam-parameters.xsl"?>
<?oxygen RNGSchema="mpls-oam-parameters.rng" type="xml"?>
<registry xmlns="http://www.iana.org/assignments" id="mpls-oam-parameters">
  <title>Multiprotocol Label Switching (MPLS) Operations, Administration, and Management (OAM) Parameters</title>
  <created>2011-10-21</created>
  <updated>2011-11-21</updated>

  <registry id="fault-message-type">
    <title>MPLS Fault OAM Message Type Registry</title>
    <registration_rule>Standards Action</registration_rule>
    <xref type="rfc" data="rfc6427"/>
    <record>
      <value>0</value>
      <description>Reserved</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>1</value>
      <description>Alarm Indication Signal (AIS)</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>2</value>
      <description>Lock Report (LKR)</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>3-251</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>252-255</value>
      <description>Reserved for Experimental Use</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
  </registry>
  
  <registry id="fault-flag">
    <title>MPLS Fault OAM Flag Registry</title>
    <registration_rule>Standards Action</registration_rule>
    <xref type="rfc" data="rfc6427"/>
    <record>
      <value>0-5</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>6</value>
      <hex>0x2</hex>
      <description>L-Flag</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>7</value>
      <hex>0x1</hex>
      <description>R-Flag</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
  </registry>
  
  <registry id="fault-tlv-rules">
    <title>MPLS Fault OAM TLV Registry</title>
    <xref type="rfc" data="rfc6427"/>
    <record>
      <value>0-191</value>
    <registration_rule>Standards Action</registration_rule>
    </record>
    <record>
    <value>192-247</value>
    <registration_rule>Specification Required</registration_rule>
    </record>
  </registry>
  
    <registry id="fault-tlv">
    <record>
      <value>0</value>
      <description>Reserved</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>1</value>
      <description>Interface Identifier TLV</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>2</value>
      <description>Global Identifier</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
    <record>
      <value>3-247</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>248-255</value>
      <description>Reserved for Experimental Use</description>
      <xref type="rfc" data="rfc6427"/>
    </record>
  </registry>
  
  <registry id="psc-request">
    <title>MPLS PSC Request Registry</title>
    <registration_rule>Standards Action</registration_rule>
    <xref type="rfc" data="rfc6378"/>
    <record>
      <value>0</value>
      <description>No Request</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>1</value>
      <description>Do-not-Revert</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>2-3</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>4</value>
      <description>Wait-to-Restore</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>5</value>
      <description>Manual Switch</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>6</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>7</value>
      <description>Signal Degrade</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>8-9</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>10</value>
      <description>Signal Fail</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>11</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>12</value>
      <description>Forced Switch</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>13</value>
      <description>Unassigned</description>
    </record>
    <record>
      <value>14</value>
      <description>Lockout of protection</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>15</value>
      <description>Unassigned</description>
    </record>
  </registry>
  
  <registry id="psc-tlv">
    <title>MPLS PSC TLV Registry</title>
    <registration_rule>IETF Review</registration_rule>
    <xref type="rfc" data="rfc6378"/>
    <record>
      <value>0</value>
      <description>Reserved</description>
      <xref type="rfc" data="rfc6378"/>
    </record>
    <record>
      <value>1-65535</value>
      <description>Unassigned</description>
    </record>
  </registry>
  
  
  <people/>
</registry>