Skip to main content

A YANG Data Model for Alarm Management
draft-ietf-ccamp-alarm-module-09

The information below is for an old version of the document that is already published as an RFC.
Document Type
This is an older version of an Internet-Draft that was ultimately published as RFC 8632.
Authors Stefan Vallin , Martin Björklund
Last updated 2022-05-11 (Latest revision 2019-04-11)
Replaces draft-vallin-ccamp-alarm-module
RFC stream Internet Engineering Task Force (IETF)
Intended RFC status Proposed Standard
Formats
Yang Validation 0 errors, 0 warnings
Reviews
Additional resources Yang catalog entry for ietf-alarms-x733@2019-03-21.yang
Yang catalog entry for ietf-alarms@2019-04-10.yang
Yang impact analysis for draft-ietf-ccamp-alarm-module
Mailing list discussion
Stream WG state Submitted to IESG for Publication
Document shepherd Daniele Ceccarelli
Shepherd write-up Show Last changed 2019-01-09
IESG IESG state Became RFC 8632 (Proposed Standard)
Action Holders
(None)
Consensus boilerplate Yes
Telechat date (None)
Responsible AD Deborah Brungard
Send notices to Daniele Ceccarelli <daniele.ceccarelli@ericsson.com>
IANA IANA review state Version Changed - Review Needed
IANA action state RFC-Ed-Ack
draft-ietf-ccamp-alarm-module-09
Network Working Group                                          S. Vallin
Internet-Draft                                          Stefan Vallin AB
Intended status: Standards Track                            M. Bjorklund
Expires: October 13, 2019                                          Cisco
                                                          April 11, 2019

                           YANG Alarm Module
                    draft-ietf-ccamp-alarm-module-09

Abstract

   This document defines a YANG module for alarm management.  It
   includes functions for alarm list management, alarm shelving and
   notifications to inform management systems.  There are also
   operations to manage the operator state of an alarm and
   administrative alarm procedures.  The module carefully maps to
   relevant alarm standards.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at https://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on October 13, 2019.

Copyright Notice

   Copyright (c) 2019 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (https://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of

Vallin & Bjorklund      Expires October 13, 2019                [Page 1]
Internet-Draft              YANG Alarm Module                 April 2019

   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
     1.1.  Terminology and Notation  . . . . . . . . . . . . . . . .   3
   2.  Objectives  . . . . . . . . . . . . . . . . . . . . . . . . .   5
   3.  Alarm Module Concepts . . . . . . . . . . . . . . . . . . . .   5
     3.1.  Alarm Definition  . . . . . . . . . . . . . . . . . . . .   5
     3.2.  Alarm Type  . . . . . . . . . . . . . . . . . . . . . . .   6
     3.3.  Identifying the Alarming Resource . . . . . . . . . . . .   8
     3.4.  Identifying Alarm Instances . . . . . . . . . . . . . . .   9
     3.5.  Alarm Lifecycle . . . . . . . . . . . . . . . . . . . . .   9
       3.5.1.  Resource Alarm Lifecycle  . . . . . . . . . . . . . .  10
       3.5.2.  Operator Alarm Lifecycle  . . . . . . . . . . . . . .  10
       3.5.3.  Administrative Alarm Lifecycle  . . . . . . . . . . .  11
     3.6.  Root Cause, Impacted Resources and Related
           Alarms  . . . . . . . . . . . . . . . . . . . . . . . . .  11
     3.7.  Alarm Shelving  . . . . . . . . . . . . . . . . . . . . .  13
     3.8.  Alarm Profiles  . . . . . . . . . . . . . . . . . . . . .  13
   4.  Alarm Data Model  . . . . . . . . . . . . . . . . . . . . . .  13
     4.1.  Alarm Control . . . . . . . . . . . . . . . . . . . . . .  15
       4.1.1.  Alarm Shelving  . . . . . . . . . . . . . . . . . . .  15
     4.2.  Alarm Inventory . . . . . . . . . . . . . . . . . . . . .  15
     4.3.  Alarm Summary . . . . . . . . . . . . . . . . . . . . . .  16
     4.4.  The Alarm List  . . . . . . . . . . . . . . . . . . . . .  17
     4.5.  The Shelved Alarms List . . . . . . . . . . . . . . . . .  19
     4.6.  Alarm Profiles  . . . . . . . . . . . . . . . . . . . . .  19
     4.7.  Operations  . . . . . . . . . . . . . . . . . . . . . . .  20
     4.8.  Notifications . . . . . . . . . . . . . . . . . . . . . .  20
   5.  Relationship to the ietf-hardware YANG module . . . . . . . .  20
   6.  Alarm YANG Module . . . . . . . . . . . . . . . . . . . . . .  21
   7.  X.733 Extensions  . . . . . . . . . . . . . . . . . . . . . .  53
   8.  The X.733 Mapping Module  . . . . . . . . . . . . . . . . . .  53
   9.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .  65
   10. Security Considerations . . . . . . . . . . . . . . . . . . .  65
   11. Acknowledgements  . . . . . . . . . . . . . . . . . . . . . .  66
   12. References  . . . . . . . . . . . . . . . . . . . . . . . . .  67
     12.1.  Normative References . . . . . . . . . . . . . . . . . .  67
     12.2.  Informative References . . . . . . . . . . . . . . . . .  68
   Appendix A.  Vendor-specific Alarm Types Example  . . . . . . . .  69
   Appendix B.  Alarm Inventory Example  . . . . . . . . . . . . . .  70
   Appendix C.  Alarm List Example . . . . . . . . . . . . . . . . .  71
   Appendix D.  Alarm Shelving Example . . . . . . . . . . . . . . .  72
   Appendix E.  X.733 Mapping Example  . . . . . . . . . . . . . . .  73
   Appendix F.  Relationship to other alarm standards  . . . . . . .  74
     F.1.  Alarm definition  . . . . . . . . . . . . . . . . . . . .  74

Vallin & Bjorklund      Expires October 13, 2019                [Page 2]
Internet-Draft              YANG Alarm Module                 April 2019

     F.2.  Data model  . . . . . . . . . . . . . . . . . . . . . . .  76
       F.2.1.  X.733 . . . . . . . . . . . . . . . . . . . . . . . .  76
       F.2.2.  RFC 3877, the Alarm MIB . . . . . . . . . . . . . . .  76
       F.2.3.  3GPP Alarm IRP  . . . . . . . . . . . . . . . . . . .  77
       F.2.4.  G.7710  . . . . . . . . . . . . . . . . . . . . . . .  77
   Appendix G.  Alarm Usability Requirements . . . . . . . . . . . .  77
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .  81

1.  Introduction

   This document defines a YANG [RFC7950] module for alarm management.
   The purpose is to define a standardized alarm interface for network
   devices that can be easily integrated into management applications.
   The model is also applicable as a northbound alarm interface in the
   management applications.

   Alarm monitoring is a fundamental part of monitoring the network.
   Raw alarms from devices do not always tell the status of the network
   services or necessarily point to the root cause.  However, being able
   to feed alarms to the alarm management application in a standardized
   format is a starting point for performing higher level network
   assurance tasks.

   The design of the module is based on experience from using and
   implementing available alarm standards from ITU [X.733], 3GPP
   [ALARMIRP] and ANSI [ISA182].

1.1.  Terminology and Notation

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in BCP
   14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.

   The following terms are defined in [RFC7950]:

   o  action

   o  client

   o  data tree

   o  server

   The following terms are used within this document:

Vallin & Bjorklund      Expires October 13, 2019                [Page 3]
Internet-Draft              YANG Alarm Module                 April 2019

   o  Alarm (the general concept): An alarm signifies an undesirable
      state in a resource that requires corrective action.

   o  Fault: A fault is the underlying cause of an undesired behavior.
      There is no trivial one-to-one mapping between faults and alarms.
      One fault may result in several alarms in case the system lacks
      root-cause and correlation capabilities.  An alarm might not have
      an underlying fault as a cause.  For example, imagine a bad Mean
      Opinion Score (MOS) alarm from a Voice over IP (VOIP) probe and
      the cause being non-optimal QoS configuration.

   o  Alarm Type: An alarm type identifies a possible unique alarm state
      for a resource.  Alarm types are names to identify the state like
      "link-alarm", "jitter-violation", "high-disk-utilization".

   o  Resource: A fine-grained identification of the alarming resource,
      for example: an interface, a process.

   o  Alarm Instance: The alarm state for a specific resource and alarm
      type.  For example ("GigabitEthernet0/15", link-alarm).  An entry
      in the alarm list.

   o  Cleared alarm: A cleared alarm is an alarm where the system
      considers the undesired state to be cleared.  Operators can not
      clear alarms, clearance is managed by the system.  For example, a
      linkUp notification can be considered a clear condition for a
      linkDown state.

   o  Closed alarm: Operators can close alarms irrespective of the alarm
      being cleared or not.  A closed alarm indicates that the alarm
      does not need attention, either since the corrective action has
      been taken or that it can be ignored for other reasons.

   o  Alarm Inventory: A list of all possible alarm types on a system.

   o  Alarm Shelving: Blocking alarms according to specific criteria.

   o  Corrective Action: An action taken by an operator or automation
      routine in order to minimize the impact of the alarm or resolve
      the root cause.

   o  Management System: The alarm management application that consumes
      the alarms, i.e., acts as a client.

   o  System: The system that implements this YANG alarm module, i.e.,
      acts as a server.  This corresponds to a network device or a
      management application that provides a northbound alarm interface.

Vallin & Bjorklund      Expires October 13, 2019                [Page 4]
Internet-Draft              YANG Alarm Module                 April 2019

   Tree diagrams used in this document follow the notation defined in
   [RFC8340].

2.  Objectives

   The objectives for the design of the Alarm Module are:

   o  Simple to use.  If a system supports this module, it shall be
      straight-forward to integrate this into a YANG based alarm
      manager.

   o  View alarms as states on resources and not as discrete
      notifications.

   o  To provide a precise definition of "alarm" in order to exclude
      general events that should not be forwarded as alarm
      notifications.

   o  To provide precise identification of alarm types and alarm
      instances.

   o  A management system should be able to pull all available alarm
      types from a system, i.e., read the alarm inventory from a system.
      This makes it possible to prepare alarm operators with
      corresponding alarm instructions.

   o  Address alarm usability requirements, see Appendix G.  While IETF
      and telecom standards have addressed alarms mostly from a protocol
      perspective, the process industry has published several relevant
      standards addressing requirements for a useful alarm interface;
      [EEMUA], [ISA182].  This alarm module defines usability
      requirements as well as a YANG data model.

   o  Mapping to [X.733], which is a requirement for some alarm systems.
      Still, keep some of the X.733 concepts out of the core model in
      order to make the model small and easy to understand.

3.  Alarm Module Concepts

   This section defines the fundamental concepts behind the data model.
   This section is rooted in the works of Vallin et. al [ALARMSEM].

3.1.  Alarm Definition

   An alarm signifies an undesirable state in a resource that requires
   corrective action.

   There are two main things to remember from this definition:

Vallin & Bjorklund      Expires October 13, 2019                [Page 5]
Internet-Draft              YANG Alarm Module                 April 2019

   1.  the definition focuses on leaving out events and logging
       information in general.  Alarms should only be used for undesired
       states that require action.

   2.  the definition also focuses on alarms as a state on a resource,
       not the notifications that report the state changes.

   See Appendix F for information how this definition relates to other
   alarm standards.

3.2.  Alarm Type

   This document defines an alarm type with an alarm type id and an
   alarm type qualifier.

   The alarm type id is modeled as a YANG identity.  With YANG
   identities, new alarm types can be defined in a distributed fashion.
   YANG identities are hierarchical, which means that a hierarchy of
   alarm types can be defined.

   Standards and vendors should define their own alarm type identities
   based on this definition.

   The use of YANG identities means that all possible alarms are
   identified at design time.  This explicit declaration of alarm types
   makes it easier to allow for alarm qualification reviews and
   preparation of alarm actions and documentation.

   There are occasions where the alarm types are not known at design
   time.  An example is a system with digital inputs that allows users
   to connect detectors, such as smoke detectors, to the inputs.  In
   this case it is a configuration action that says that certain
   connectors are fire alarms for example.

   In order to allow for dynamic addition of alarm types the alarm
   module allows for further qualification of the identity-based alarm
   type using a string.  A potential drawback of this is that there is a
   significant risk that alarm operators will receive alarm types as a
   surprise.  They do not know how to resolve the problem since a
   defined alarm procedure does not necessarily exist.  To avoid this
   risk the system MUST publish all possible alarm types in the alarm
   inventory, see Section 4.2.

   A vendor or standards organization can define their own alarm type
   hierarchy.  The example below shows a hierarchy based on X.733 event
   types:

Vallin & Bjorklund      Expires October 13, 2019                [Page 6]
Internet-Draft              YANG Alarm Module                 April 2019

     import ietf-alarms {
       prefix al;
     }
     identity vendor-alarms {
       base al:alarm-type;
     }
     identity communications-alarm {
       base vendor-alarms;
     }
     identity link-alarm {
       base communications-alarm;
     }

   Alarm types can be abstract.  An abstract alarm type is used as a
   base for defining hierarchical alarm types.  Concrete alarm types are
   used for alarm states and appear in the alarm inventory.  There are
   two kinds of concrete alarm types:

   1.  The last subordinate identity in the "alarm-type-id" hierarchy is
       concrete, for example: "alarm-identity.environmental-
       alarm.smoke".  In this example "alarm-identity" and
       "environmental-alarm" are abstract YANG identities, whereas
       "smoke" is a concrete YANG identity.

   2.  The YANG identity hierarchy is abstract and the concrete alarm
       type is defined by the dynamic alarm qualifier string, for
       example: "alarm-identity.environmental-alarm.external-detector"
       with alarm-type-qualifier "smoke".

   For example:

Vallin & Bjorklund      Expires October 13, 2019                [Page 7]
Internet-Draft              YANG Alarm Module                 April 2019

     // Alternative 1: concrete alarm type identity
     import ietf-alarms {
       prefix al;
     }
     identity environmental-alarm {
       base al:alarm-type;
       description "Abstract alarm type";
     }
     identity smoke {
       base environmental-alarm;
       description "Concrete alarm type";
     }

     // Alternative 2: concrete alarm type qualifier
     import ietf-alarms {
       prefix al;
     }
     identity environmental-alarm {
       base al:alarm-type;
       description "Abstract alarm type";
     }
     identity external-detector {
       base environmental-alarm;
       description
         "Abstract alarm type, a run-time configuration
          procedure sets the type of alarm detected. This will
          be reported in the alarm-type-qualifier.";
     }

   A server SHOULD strive to minimize the number of dynamically defined
   alarm types.

3.3.  Identifying the Alarming Resource

   It is of vital importance to be able to refer to the alarming
   resource.  This reference must be as fine-grained as possible.  If
   the alarming resource exists in the data tree then an instance-
   identifier MUST be used with the full path to the object.

   When the module is used in a controller/orchestrator/manager the
   original device resource identification can be modified to include
   the device in the path.  The details depend on how devices are
   identified, and are out of scope for this specification.

   Example:

      The original device alarm might identify the resource as
      "/dev:interfaces/dev:interface[dev:name='FastEthernet1/0']".

Vallin & Bjorklund      Expires October 13, 2019                [Page 8]
Internet-Draft              YANG Alarm Module                 April 2019

      The resource identification in the manager could look something
      like: "/mgr:devices/mgr:device[mgr:name='xyz123']/dev:interfaces/
      dev:interface[dev:name='FastEthernet1/0']"

   This module also allows for alternate naming of the alarming resource
   if it is not available in the data tree.

3.4.  Identifying Alarm Instances

   A primary goal of this alarm module is to remove any ambiguity in how
   alarm notifications are mapped to an update of an alarm instance.
   The X.733 and 3GPP documents were not clear on this point.  This YANG
   alarm module states that the tuple (resource, alarm type identifier,
   alarm type qualifier) corresponds to a single alarm instance.  This
   means that alarm notifications for the same resource and same alarm
   type are matched to update the same alarm instance.  These three
   leafs are therefore used as the key in the alarm list:

     list alarm {
       key "resource alarm-type-id alarm-type-qualifier";
       ...
     }

3.5.  Alarm Lifecycle

   The alarm model clearly separates the resource alarm lifecycle from
   the operator and administrative lifecycles of an alarm.

   o  resource alarm lifecycle: the alarm instrumentation that controls
      alarm raise, clearance, and severity changes.

   o  operator alarm lifecycle: operators acting upon alarms with
      actions like acknowledgment and closing.  Closing an alarm implies
      that the operator considers the corrective action performed.
      Operators can also shelf (block/filter) alarms in order to avoid
      nuisance alarms.

   o  administrative alarm lifecycle: purging (deleting) unwanted alarms
      and compressing the alarm status change list.  This module exposes
      operations to manage the administrative lifecycle.  The server may
      also perform these operations based on other policies, but how
      that is done is out of scope for this document.

   A server SHOULD describe how long it retains cleared/closed alarms:
   until manually purged or if it has an automatic removal policy.  How
   this is done is outside the scope of this document.

Vallin & Bjorklund      Expires October 13, 2019                [Page 9]
Internet-Draft              YANG Alarm Module                 April 2019

3.5.1.  Resource Alarm Lifecycle

   From a resource perspective, an alarm can for example have the
   following lifecycle: raise, change severity, change severity, clear,
   being raised again, etc.  All of these status changes can have
   different alarm texts generated by the instrumentation.  Two
   important things to note:

   1.  Alarms are not deleted when they are cleared.  Deleting alarms is
       an administrative process.  The alarm module defines an action
       "purge-alarms" that deletes alarms.

   2.  Alarms are not cleared by operators, only the underlying
       instrumentation can clear an alarm.  Operators can close alarms.

   The YANG tree representation below illustrates the resource oriented
   lifecycle:

     +--ro alarm* [resource alarm-type-id alarm-type-qualifier]
        ...
        +--ro is-cleared                 boolean
        +--ro last-changed               yang:date-and-time
        +--ro perceived-severity         severity
        +--ro alarm-text                 alarm-text
        +--ro status-change* [time] {alarm-history}?
           +--ro time                    yang:date-and-time
           +--ro perceived-severity      severity-with-clear
           +--ro alarm-text              alarm-text

   For every status change from the resource perspective a row is added
   to the "status-change" list, if the server implements the feature
   "alarm-history".  The feature "alarm-history" is optional to
   implement, since keeping the alarm history may have an impact on the
   server's memory resources.

   The last status values are also represented as leafs for the alarm.
   Note well that the alarm severity does not include "cleared", alarm
   clearance is a boolean flag.

   An alarm can therefore look like this: (("GigabitEthernet0/25", link-
   alarm,""), false, 2018-04-08T08:20:10.00Z, major, "Interface
   GigabitEthernet0/25 down")

3.5.2.  Operator Alarm Lifecycle

   Operators can act upon alarms using the set-operator-state action:

Vallin & Bjorklund      Expires October 13, 2019               [Page 10]
Internet-Draft              YANG Alarm Module                 April 2019

     +--ro alarm* [resource alarm-type-id alarm-type-qualifier]
        ...
        +--ro operator-state-change* [time] {operator-actions}?
        |  +--ro time        yang:date-and-time
        |  +--ro operator    string
        |  +--ro state       operator-state
        |  +--ro text?       string
        +---x set-operator-state {operator-actions}?
           +---w input
              +---w state    writable-operator-state
              +---w text?    string

   The operator state for an alarm can be: "none", "ack", "shelved", and
   "closed".  Alarm deletion (using the action "purge-alarms") can use
   this state as a criterion.  For example, a closed alarm is an alarm
   where the operator has performed any required corrective actions.
   Closed alarms are good candidates for being purged.

3.5.3.  Administrative Alarm Lifecycle

   Deleting alarms from the alarm list is considered an administrative
   action.  This is supported by the "purge-alarms" action.  The "purge-
   alarms" action takes a filter as input.  The filter selects alarms
   based on the operator and resource lifecycle such as "all closed
   cleared alarms older than a time specification".  The server may also
   perform these operations based on other policies, but how that is
   done is out of scope for this document.

   Purged alarms are removed from the alarm list.  Note well, if the
   alarm resource state changes after a purge, the alarm will reappear
   in the alarm list.

   Alarms can be compressed.  Compressing an alarm deletes all entries
   in the alarm's "status-change" list except for the last status
   change.  A client can perform this using the "compress-alarms"
   action.  The server may also perform these operations based on other
   policies, but how that is done is out of scope for this document.

3.6.  Root Cause, Impacted Resources and Related Alarms

   The alarm module does not mandate any requirements for the system to
   support alarm correlation or root-cause and service-impact analysis.
   However, if such features are supported, this section describes how
   the results of such analysis are represented in the data model.
   These parts of the model are optional.  The module supports three
   scenarios:

Vallin & Bjorklund      Expires October 13, 2019               [Page 11]
Internet-Draft              YANG Alarm Module                 April 2019

   Root cause analysis:  An alarm can indicate candidate root cause
      resources, for example: a database issue alarm referring to a full
      disc partition.

   Service impact analysis:  An alarm can refer to potential impacted
      resources, for example: an interface alarm referring to impacted
      network services

   Alarm correlation:  Dependencies between alarms, several alarms can
      be grouped as relating to each other, for example a streaming
      media alarm relating to a high jitter alarm.

   Different systems have varying degrees of alarm correlation and
   analysis capabilities, and the intent of the alarm module is to
   enable any capability, including none.

   The general principle of this alarm module is to limit the amount of
   alarms.  In many cases several resources are affected for a given
   underlying problem.  A full disk will of course impact databases and
   applications as well.  The recommendation is to have a single alarm
   for the underlying problem and list the affected resources in the
   alarm, rather than having separate alarms for each resource.

   The alarm has one leaf-list to identify possible "impacted-resources"
   and a leaf-list to identify possible "root-cause-resources".  These
   serves as hints only.  It is up to the client application to use this
   information to present the overall status.  Using the disk full
   example, a good alarm would be to use the hard disk partition as the
   alarming resource and add the database and applications into the
   "impacted-resources" leaf-list.

   A system should always strive to identify the resource that can be
   acted upon as the "resource" leaf.  The "impacted-resource" leaf-list
   shall be used to identify any side-effects of the alarm.  The
   impacted resources can not be acted upon to fix the problem.  The
   disk full example above illustrates the principle; you can not fix
   the underlying issue by database operations.  However, you need to
   pay attention to the database to perform any operations that limits
   the impact of problem.

   On some occasions the system might not be capable of detecting the
   root cause, the resource that can be acted upon.  The instrumentation
   in this case only monitors the side-effect and raises an alarm to
   indicate a situation requiring attention.  The instrumentation still
   might identify possible candidates for the root-cause resource.  In
   this case the "root-cause-resource" leaf-list can be used to indicate
   the candidate root-cause resources.  An example of this kind of alarm
   might be an active test tool that detects an SLA violation on a VPN

Vallin & Bjorklund      Expires October 13, 2019               [Page 12]
Internet-Draft              YANG Alarm Module                 April 2019

   connection and identifies the devices along the chain as candidate
   root causes.

   The alarm module also supports a way to associate different alarms to
   each other with the "related-alarm" list.  This list enables the
   server to inform the client that certain alarms are related to other
   alarms.

   Note well that this module does not prescribe any dependencies or
   preference between the above alarm correlation mechanisms.  Different
   systems have different capabilities and the above described
   mechanisms are available to support the instrumentation features.

3.7.  Alarm Shelving

   Alarm shelving is an important function in order for alarm management
   applications and operators to stop superfluous alarms.  A shelved
   alarm implies that any alarms fulfilling these criteria are ignored
   (blocked/filtered).  Shelved alarms appear in a dedicated shelved
   alarm list in order to be filtered out from the alarm list in order
   for the main alarm list to only contain entries of interest.  Shelved
   alarms do not generate notifications but the shelved alarm list is
   updated with any alarm state changes.

   Alarm shelving is optional to implement, since matching alarms
   against shelf criteria may have an impact on the server's processing
   resources.

3.8.  Alarm Profiles

   Alarm profiles are used to configure further information to an alarm
   type.  This module supports configuring severity levels overriding
   the system default levels.  This corresponds to the Alarm Assignment
   Profile, ASAP, functionality in M.3100 [M.3100] and M.3160 [M.3160].
   Other standard or enterprise modules can augment this list with
   further alarm type information.

4.  Alarm Data Model

   The fundamental parts of the data model are the "alarm-list" with
   associated notifications and the "alarm-inventory" list of all
   possible alarm types.  These MUST be implemented by a system.  The
   rest of the data model are made conditional with the YANG features
   "operator-actions", "alarm-shelving", "alarm-history", "alarm-
   summary", "alarm-profile", and "severity-assignment".

   The data model has the following overall structure:

Vallin & Bjorklund      Expires October 13, 2019               [Page 13]
Internet-Draft              YANG Alarm Module                 April 2019

     +--rw control
     |  +--rw max-alarm-status-changes?   union
     |  +--rw notify-status-changes?      enumeration
     |  +--rw notify-severity-level?      severity
     |  +--rw alarm-shelving {alarm-shelving}?
     |        ...
     +--ro alarm-inventory
     |  +--ro alarm-type* [alarm-type-id alarm-type-qualifier]
     |        ...
     +--ro summary {alarm-summary}?
     |  +--ro alarm-summary* [severity]
     |  |     ...
     |  +--ro shelves-active?   empty {alarm-shelving}?
     +--ro alarm-list
     |  +--ro number-of-alarms?   yang:gauge32
     |  +--ro last-changed?       yang:date-and-time
     |  +--ro alarm* [resource alarm-type-id alarm-type-qualifier]
     |  |     ...
     |  +---x purge-alarms
     |  |     ...
     |  +---x compress-alarms {alarm-history}?
     |        ...
     +--ro shelved-alarms {alarm-shelving}?
     |  +--ro number-of-shelved-alarms?      yang:gauge32
     |  +--ro shelved-alarms-last-changed?   yang:date-and-time
     |  +--ro shelved-alarm*
     |  |       [resource alarm-type-id alarm-type-qualifier]
     |  |     ...
     |  +---x purge-shelved-alarms
     |  |     ...
     |  +---x compress-shelved-alarms {alarm-history}?
     |        ...
     +--rw alarm-profile*
             [alarm-type-id alarm-type-qualifier-match resource]
             {alarm-profile}?
        +--rw alarm-type-id                        alarm-type-id
        +--rw alarm-type-qualifier-match           string
        +--rw resource                             resource-match
        +--rw description                          string
        +--rw alarm-severity-assignment-profile
                {severity-assignment}?
              ...

Vallin & Bjorklund      Expires October 13, 2019               [Page 14]
Internet-Draft              YANG Alarm Module                 April 2019

4.1.  Alarm Control

   The "/alarms/control/notify-status-changes" leaf controls if
   notifications are sent for all state changes, only raise and clear,
   or only notifications more severe than a configured level.  This
   feature in combination with alarm shelving corresponds to the ITU
   Alarm Report Control functionality, see Appendix F.2.4.

   Every alarm has a list of status changes.  The length of this list is
   controlled by "/alarms/control/max-alarm-status-changes".  When the
   list is full and a new entry created, the oldest entry is removed.

4.1.1.  Alarm Shelving

   The shelving control tree is shown below:

     +--rw control
        +--rw alarm-shelving {alarm-shelving}?
           +--rw shelf* [name]
              +--rw name           string
              +--rw resource*      resource-match
              +--rw alarm-type*
              |       [alarm-type-id alarm-type-qualifier-match]
              |  +--rw alarm-type-id                 alarm-type-id
              |  +--rw alarm-type-qualifier-match    string
              +--rw description?   string

   Shelved alarms are shown in a dedicated shelved alarm list.  Matching
   alarms MUST appear in the /alarms/shelved-alarms/shelved-alarm list,
   and non-matching /alarms MUST appear in the /alarms/alarm-list/alarm
   list.  The server does not send any notifications for shelved alarms.

   Shelving and unshelving can only be performed by editing the shelf
   configuration.  It cannot be performed on individual alarms.  The
   server will add an operator state indicating that the alarm was
   shelved/unshelved.

   A leaf (/alarms/summary/shelves-active) in the alarm summary
   indicates if there are shelved alarms.

   A system can select to not support the shelving feature.

4.2.  Alarm Inventory

   The alarm inventory represents all possible alarm types that may
   occur in the system.  A management system may use this to build alarm
   procedures.  The alarm inventory is relevant for several reasons:

Vallin & Bjorklund      Expires October 13, 2019               [Page 15]
Internet-Draft              YANG Alarm Module                 April 2019

      The system might not implement all defined alarm type identities,
      and some alarm identities are abstract.

      The system has configured dynamic alarm types using the alarm
      qualifier.  The inventory makes it possible for the management
      system to discover these.

   Note that the mechanism whereby dynamic alarm types are added using
   the alarm type qualifier MUST populate this list.

   The optional leaf-list "resource" in the alarm inventory enables the
   system to publish for which resources a given alarm type may appear.

   A server MUST implement the alarm inventory in order to enable
   controlled alarm procedures in the client.

   A server implementer may want to document the alarm inventory for
   off-line processing by clients.  The file format defined in
   [I-D.ietf-netmod-yang-instance-file-format] can be used for this
   purpose.

   The alarm inventory tree is shown below:

     +--ro alarm-inventory
        +--ro alarm-type* [alarm-type-id alarm-type-qualifier]
           +--ro alarm-type-id           alarm-type-id
           +--ro alarm-type-qualifier    alarm-type-qualifier
           +--ro resource*               resource-match
           +--ro will-clear              boolean
           +--ro severity-levels*        severity
           +--ro description             string

4.3.  Alarm Summary

   The alarm summary list summarizes alarms per severity; how many
   cleared, cleared and closed, and closed.  It also gives an indication
   if there are shelved alarms.

   The alarm summary tree is shown below:

Vallin & Bjorklund      Expires October 13, 2019               [Page 16]
Internet-Draft              YANG Alarm Module                 April 2019

     +--ro summary {alarm-summary}?
        +--ro alarm-summary* [severity]
        |  +--ro severity                  severity
        |  +--ro total?                    yang:gauge32
        |  +--ro not-cleared?              yang:gauge32
        |  +--ro cleared?                  yang:gauge32
        |  +--ro cleared-not-closed?       yang:gauge32
        |  |       {operator-actions}?
        |  +--ro cleared-closed?           yang:gauge32
        |  |       {operator-actions}?
        |  +--ro not-cleared-closed?       yang:gauge32
        |  |       {operator-actions}?
        |  +--ro not-cleared-not-closed?   yang:gauge32
        |          {operator-actions}?
        +--ro shelves-active?   empty {alarm-shelving}?

4.4.  The Alarm List

   The alarm list (/alarms/alarm-list) is a function from the tuple
   (resource, alarm type, alarm type qualifier) to the current composite
   alarm state.  The composite state includes states for the resource
   lifecycle such as severity, clearance flag and operator states such
   as acknowledgment.  This means that for a given resource and alarm
   type the alarm list shows the current states of the alarm such as
   acknowledged and cleared status.

   +--ro alarm-list
      +--ro number-of-alarms?   yang:gauge32
      +--ro last-changed?       yang:date-and-time
      +--ro alarm* [resource alarm-type-id alarm-type-qualifier]
      |  +--ro resource                 resource
      |  +--ro alarm-type-id            alarm-type-id
      |  +--ro alarm-type-qualifier     alarm-type-qualifier
      |  +--ro alt-resource*            resource
      |  +--ro related-alarm*
      |  |       [resource alarm-type-id alarm-type-qualifier]
      |  |       {alarm-correlation}?
      |  |  +--ro resource
      |  |  |       -> /alarms/alarm-list/alarm/resource
      |  |  +--ro alarm-type-id           leafref
      |  |  +--ro alarm-type-qualifier    leafref
      |  +--ro impacted-resource*       resource
      |  |       {service-impact-analysis}?
      |  +--ro root-cause-resource*     resource
      |  |       {root-cause-analysis}?
      |  +--ro time-created             yang:date-and-time
      |  +--ro is-cleared               boolean

Vallin & Bjorklund      Expires October 13, 2019               [Page 17]
Internet-Draft              YANG Alarm Module                 April 2019

      |  +--ro last-raised              yang:date-and-time
      |  +--ro last-changed             yang:date-and-time
      |  +--ro perceived-severity       severity
      |  +--ro alarm-text               alarm-text
      |  +--ro status-change* [time] {alarm-history}?
      |  |  +--ro time                  yang:date-and-time
      |  |  +--ro perceived-severity    severity-with-clear
      |  |  +--ro alarm-text            alarm-text
      |  +--ro operator-state-change* [time] {operator-actions}?
      |  |  +--ro time        yang:date-and-time
      |  |  +--ro operator    string
      |  |  +--ro state       operator-state
      |  |  +--ro text?       string
      |  +---x set-operator-state {operator-actions}?
      |  |  +---w input
      |  |     +---w state    writable-operator-state
      |  |     +---w text?    string
      |  +---n operator-action {operator-actions}?
      |     +-- time        yang:date-and-time
      |     +-- operator    string
      |     +-- state       operator-state
      |     +-- text?       string
      +---x purge-alarms
      |  +---w input
      |  |  +---w alarm-clearance-status    enumeration
      |  |  +---w older-than!
      |  |  |  +---w (age-spec)?
      |  |  |     +--:(seconds)
      |  |  |     |  +---w seconds?   uint16
      |  |  |     +--:(minutes)
      |  |  |     |  +---w minutes?   uint16
      |  |  |     +--:(hours)
      |  |  |     |  +---w hours?     uint16
      |  |  |     +--:(days)
      |  |  |     |  +---w days?      uint16
      |  |  |     +--:(weeks)
      |  |  |        +---w weeks?     uint16
      |  |  +---w severity!
      |  |  |  +---w (sev-spec)?
      |  |  |     +--:(below)
      |  |  |     |  +---w below?   severity
      |  |  |     +--:(is)
      |  |  |     |  +---w is?      severity
      |  |  |     +--:(above)
      |  |  |        +---w above?   severity
      |  |  +---w operator-state-filter! {operator-actions}?
      |  |     +---w state?   operator-state
      |  |     +---w user?    string

Vallin & Bjorklund      Expires October 13, 2019               [Page 18]
Internet-Draft              YANG Alarm Module                 April 2019

      |  +--ro output
      |     +--ro purged-alarms?   uint32
      +---x compress-alarms {alarm-history}?
         +---w input
         |  +---w resource?               resource-match
         |  +---w alarm-type-id?
         |  |       -> /alarms/alarm-list/alarm/alarm-type-id
         |  +---w alarm-type-qualifier?   leafref
         +--ro output
            +--ro compressed-alarms?   uint32

   Every alarm has three important states, the resource clearance state
   "is-cleared", the severity "perceived-severity" and the operator
   state available in the operator state change list.

   In order to see the alarm history the resource state changes are
   available in the "status-change" list and the operator history is
   available in the "operator-state-change" list.

4.5.  The Shelved Alarms List

   The shelved alarm list has the same structure as the alarm list
   above.  It shows all the alarms that matches the shelving criteria
   (/alarms/control/alarm-shelving).

4.6.  Alarm Profiles

   Alarm profiles (/alarms/alarm-profile) is a list of configurable
   alarm types.  The list supports configurable alarm severity levels in
   the container "alarm-severity-assignment-profile".  If an alarm
   matches the configured alarm type it MUST use the configured severity
   level(s) instead of the system default.  This configuration MUST also
   be represented in the alarm inventory.

     +--rw alarm-profile*
             [alarm-type-id alarm-type-qualifier-match resource]
             {alarm-profile}?
        +--rw alarm-type-id                        alarm-type-id
        +--rw alarm-type-qualifier-match           string
        +--rw resource                             resource-match
        +--rw description                          string
        +--rw alarm-severity-assignment-profile
                {severity-assignment}?
           +--rw severity-levels*   severity

Vallin & Bjorklund      Expires October 13, 2019               [Page 19]
Internet-Draft              YANG Alarm Module                 April 2019

4.7.  Operations

   The alarm module supports the following actions to manage the alarms:

   /alarms/alarm-list/purge-alarms:  Delete alarms from the "alarm-list"
      according to specific criteria, for example all cleared alarms
      older than a specific date.

   /alarms/alarm-list/compress-alarms:  Compress the "status-change"
      list for the alarms.

   /alarms/alarm-list/alarm/set-operator-state:  Change the operator
      state for an alarm.  For example, an alarm can be acknowledged by
      setting the operator state to "ack".

   /alarms/shelved-alarm-list/purge-shelved-alarms:  Delete alarms from
      the "shelved-alarm-list" according to specific criteria, for
      example all alarms older than a specific date.

   /alarms/shelved-alarm-list/compress-shelved-alarms:  Compress the
      "status-change" list for the alarms.

4.8.  Notifications

   The alarm module supports a general notification to report alarm
   state changes.  It carries all relevant parameters for the alarm
   management application.

   There is also a notification to report that an operator changed the
   operator state on an alarm, like acknowledge.

   If the alarm inventory is changed, for example a new card type is
   inserted, a notification will tell the management application that
   new alarm types are available.

5.  Relationship to the ietf-hardware YANG module

   RFC 8348 [RFC8348] defines the "ietf-hardware" YANG data model for
   the management of hardware.  The "alarm-state" in RFC 8348 is a
   summary of the alarm severity levels that may be active on the
   specific hardware component.  It does not say anything about how
   alarms are reported, and it doesn't provide any details of the
   alarms.

   The mapping between the alarm YANG data model and the "alarm-state"
   in RFC 8348 is as follows:

Vallin & Bjorklund      Expires October 13, 2019               [Page 20]
Internet-Draft              YANG Alarm Module                 April 2019

   resource:  Corresponds to an entry in the list "/hardware/component/"

   is-cleared:  No bit set in "/hardware/component/state/alarm-state"

   perceived-severity:  Corresponding bit set in
      "/hardware/component/state/alarm-state".

   operator-state-change/state:  If the alarm is acknowledged by the
      operator, the bit "under-repair" is in "/hardware/component/state/
      alarm-state".

6.  Alarm YANG Module

   This YANG module references [RFC6991] and [XSD-TYPES].

   <CODE BEGINS> file "ietf-alarms@2019-04-10.yang"
   module ietf-alarms {
     yang-version 1.1;
     namespace "urn:ietf:params:xml:ns:yang:ietf-alarms";
     prefix al;

     import ietf-yang-types {
       prefix yang;
       reference
         "RFC 6991: Common YANG Data Types.";
     }

     organization
       "IETF CCAMP Working Group";
     contact
       "WG Web:   <http://tools.ietf.org/wg/ccamp>
        WG List:  <mailto:ccamp@ietf.org>

        Editor:   Stefan Vallin
                  <mailto:stefan@wallan.se>

        Editor:   Martin Bjorklund
                  <mailto:mbj@tail-f.com>";

     // RFC Ed.: replace XXXX with actual RFC number and
     // remove this note.

     description
       "This module defines an interface for managing alarms.  Main
        inputs to the module design are the 3GPP Alarm IRP, ITU-T X.733
        and ANSI/ISA-18.2 alarm standards.

        Main features of this module include:

Vallin & Bjorklund      Expires October 13, 2019               [Page 21]
Internet-Draft              YANG Alarm Module                 April 2019

          * Alarm list:
                    A list of all alarms.  Cleared alarms stay in
                    the list until explicitly purged.

          * Operator actions on alarms:
                    Acknowledging and closing alarms.

          * Administrative actions on alarms:
                    Purging alarms from the list according to specific
                    criteria.

          * Alarm inventory:
                    A management application can read all
                    alarm types implemented by the system.

          * Alarm shelving:
                    Shelving (blocking) alarms according
                    to specific criteria.

          * Alarm profiles:
                    A management system can attach further
                    information to alarm types, for example
                    overriding system default severity
                    levels.

        This module uses a stateful view on alarms.  An alarm is a state
        for a specific resource (note that an alarm is not a
        notification).  An alarm type is a possible alarm state for a
        resource.  For example, the tuple:

          ('link-alarm', 'GigabitEthernet0/25')

        is an alarm of type 'link-alarm' on the resource
        'GigabitEthernet0/25'.

        Alarm types are identified using YANG identities and an optional
        string-based qualifier.  The string-based qualifier allows for
        dynamic extension of the statically defined alarm types.  Alarm
        types identify a possible alarm state and not the individual
        notifications.  For example, the traditional 'link-down' and
        'link-up' notifications are two notifications referring to the
        same alarm type 'link-alarm'.

        With this design there is no ambiguity about how alarm and alarm
        clear correlation should be performed: notifications that report
        the same resource and alarm type are considered updates of the
        same alarm, e.g., clearing an active alarm or changing the
        severity of an alarm.

Vallin & Bjorklund      Expires October 13, 2019               [Page 22]
Internet-Draft              YANG Alarm Module                 April 2019

        The instrumentation can update 'severity' and 'alarm-text' on an
        existing alarm.  The above alarm example can therefore look
        like:

          (('link-alarm', 'GigabitEthernet0/25'),
           warning,
           'interface down while interface admin state is up')

        There is a clear separation between updates on the alarm from
        the underlying resource, like clear, and updates from an
        operator like acknowledge or closing an alarm:

          (('link-alarm', 'GigabitEthernet0/25'),
           warning,
           'interface down while interface admin state is up',
           cleared,
           closed)

        Administrative actions like removing closed alarms older than a
        given time is supported.

        This alarm module does not define how the underlying
        instrumentation detects and clears the specific alarms.  That
        belongs to the SDO or enterprise that owns that specific
        technology.

        The key words 'MUST', 'MUST NOT', 'REQUIRED', 'SHALL', 'SHALL
        NOT', 'SHOULD', 'SHOULD NOT', 'RECOMMENDED', 'NOT RECOMMENDED',
        'MAY', and 'OPTIONAL' in this document are to be interpreted as
        described in BCP 14 (RFC 2119) (RFC 8174) when, and only when,
        they appear in all capitals, as shown here.

        Copyright (c) 2019 IETF Trust and the persons identified as
        authors of the code.  All rights reserved.

        Redistribution and use in source and binary forms, with or
        without modification, is permitted pursuant to, and subject to
        the license terms contained in, the Simplified BSD License set
        forth in Section 4.c of the IETF Trust's Legal Provisions
        Relating to IETF Documents
        (https://trustee.ietf.org/license-info).

        This version of this YANG module is part of RFC XXXX
        (https://tools.ietf.org/html/rfcXXXX); see the RFC itself for
        full legal notices.";

     // RFC Ed.: update the date below with the date of RFC publication
     // and remove this note.

Vallin & Bjorklund      Expires October 13, 2019               [Page 23]
Internet-Draft              YANG Alarm Module                 April 2019

     revision 2019-04-10 {
       description
         "Initial revision.";
       reference
         "RFC XXXX: YANG Alarm Module";
     }

     /*
      * Features
      */

     feature operator-actions {
       description
         "This feature indicates that the system supports operator
          states on alarms.";
     }

     feature alarm-shelving {
       description
         "This feature indicates that the system supports shelving
          (blocking) alarms.

          Alarm shelving may have an impact on server processing
          resources in order to match alarms against shelf
          criteria.";
     }

     feature alarm-history {
       description
         "This feature indicates that server maintains a history of
          state changes for each alarm.  For example, if an alarm
          toggles between cleared and active 10 times, these state
          changes are present in a separate list in the alarm.

          Keeping the alarm history may have an impact on server memory
          resources.";
     }

     feature alarm-summary {
       description
         "This feature indicates that the server summarizes the number
          of alarms per severity and operator state.";
     }

     feature alarm-profile {
       description
         "The system supports clients to configure further information
          to each alarm type.";

Vallin & Bjorklund      Expires October 13, 2019               [Page 24]
Internet-Draft              YANG Alarm Module                 April 2019

     }

     feature severity-assignment {
       description
         "The system supports configurable alarm severity levels.";
       reference
         "M.3160/M.3100 Alarm Severity Assignment Profile, ASAP";
     }

     feature root-cause-analysis {
       description
         "The system supports identifying candidate root-cause
          resources for an alarm, for example a disc partition
          root cause for a logger failure alarm.";
     }

     feature service-impact-analysis {
       description
         "The system supports identifying candidate impacted
          resources for an alarm. For example, an interface state change
          resulting in a link alarm which can refer to a link as being
          impacted.";
     }

     feature alarm-correlation {
       description
         "The system supports correlating/grouping alarms
          that belong together.";
     }

     /*
      * Identities
      */

     identity alarm-type-id {
       description
         "Base identity for alarm types.  A unique identification of the
          alarm, not including the resource.  Different resources can
          share alarm types.  If the resource reports the same alarm
          type, it is to be considered to be the same alarm.  The alarm
          type is a simplification of the different X.733 and 3GPP alarm
          IRP alarm correlation mechanisms and it allows for
          hierarchical extensions.

          A string-based qualifier can be used in addition to the
          identity in order to have different alarm types based on
          information not known at design-time, such as values in
          textual SNMP Notification var-binds.

Vallin & Bjorklund      Expires October 13, 2019               [Page 25]
Internet-Draft              YANG Alarm Module                 April 2019

          Standards and vendors can define sub-identities to clearly
          identify specific alarm types.

          This identity is abstract and MUST NOT be used for alarms.";
     }

     /*
      * Common types
      */

     typedef resource {
       type union {
         type instance-identifier {
           require-instance false;
         }
         type yang:object-identifier;
         type string;
         type yang:uuid;
       }
       description
         "This is an identification of the alarming resource, such as an
          interface.  It should be as fine-grained as possible both to
          guide the operator and to guarantee uniqueness of the alarms.

          If the alarming resource is modeled in YANG, this type will
          be an instance-identifier.

          If the resource is an SNMP object, the type will be an
          object-identifier.

          If the resource is anything else, for example a distinguished
          name or a CIM path, this type will be a string.

          If the alarming object is identified by a UUID use the uuid
          type.  Be cautious when using this type, since a UUID is hard
          to use for an operator.

          If the server supports several models, the precedence should
          be in the order as given in the union definition.";
     }

     typedef resource-match {
       type union {
         type yang:xpath1.0;
         type yang:object-identifier;
         type string;
       }
       description

Vallin & Bjorklund      Expires October 13, 2019               [Page 26]
Internet-Draft              YANG Alarm Module                 April 2019

         "This type is used to match resources of type 'resource'.
          Since the type 'resource' is a union of different types, the
          'resource-match' type is also a union of corresponding types.

          If the type is given as an XPath 1.0 expression, a resource of
          type 'instance-identifier' matches if the instance is part of
          the node set that is the result of evaluating the XPath 1.0
          expression.  For example, the XPath 1.0 expression:

           /ietf-interfaces:interfaces/ietf-interfaces:interface
               [ietf-interfaces:type='ianaift:ethernetCsmacd']

          would match the resource instance-identifier:

           /if:interfaces/if:interface[if:name='eth1'],

          assuming that the interface 'eth1' is of type
          'ianaift:ethernetCsmacd'.

          If the type is given as an object identifier, a resource of
          type 'object-identifier' matches if the match object
          identifier is a prefix of the resource's object identifier.
          For example, the value:

           1.3.6.1.2.1.2.2

          would match the resource object identifier:

           1.3.6.1.2.1.2.2.1.1.5

          If the type is given as an UUID or a string, it is interpreted
          as an XML Schema regular expression, which matches a resource
          of type 'yang:uuid' or 'string' if the given regular
          expression matches the resource string.

          If the type is given as an XPath expression it is evaluated
          in the following XPath context:

            o  The set of namespace declarations is the set of prefix
               and namespace pairs for all YANG modules implemented by
               the server, where the prefix is the YANG module name and
               the namespace is as defined by the 'namespace' statement
               in the YANG module.

               If a leaf of this type is encoded in XML, all namespace
               declarations in scope on the leaf element are added to
               the set of namespace declarations.  If a prefix found in
               the XML is already present in the set of namespace

Vallin & Bjorklund      Expires October 13, 2019               [Page 27]
Internet-Draft              YANG Alarm Module                 April 2019

               declarations, the namespace in the XML is used.

            o  The set of variable bindings is empty.

            o  The function library is the core function library
               and the functions defined in Section 10 of RFC 7950.

            o  The context node is the root node in the data tree.";
       reference
         "XML Schema Part 2: Datatypes Second Edition,
            World Wide Web Consortium Recommendation
            REC-xmlschema-2-20041028";
     }

     typedef alarm-text {
       type string;
       description
         "The string used to inform operators about the alarm.  This
          MUST contain enough information for an operator to be able to
          understand the problem and how to resolve it.  If this string
          contains structure, this format should be clearly documented
          for programs to be able to parse that information.";
     }

     typedef severity {
       type enumeration {
         enum indeterminate {
           value 2;
           description
             "Indicates that the severity level could not be
              determined.  This level SHOULD be avoided.";
         }
         enum warning {
           value 3;
           description
             "The 'warning' severity level indicates the detection of a
              potential or impending service affecting fault, before any
              significant effects have been felt.  Action should be
              taken to further diagnose (if necessary) and correct the
              problem in order to prevent it from becoming a more
              serious service affecting fault.";
         }
         enum minor {
           value 4;
           description
             "The 'minor' severity level indicates the existence of a
              non-service affecting fault condition and that corrective
              action should be taken in order to prevent a more serious

Vallin & Bjorklund      Expires October 13, 2019               [Page 28]
Internet-Draft              YANG Alarm Module                 April 2019

              (for example, service affecting) fault.  Such a severity
              can be reported, for example, when the detected alarm
              condition is not currently degrading the capacity of the
              resource.";
         }
         enum major {
           value 5;
           description
             "The 'major' severity level indicates that a service
              affecting condition has developed and an urgent corrective
              action is required.  Such a severity can be reported, for
              example, when there is a severe degradation in the
              capability of the resource and its full capability must be
              restored.";
         }
         enum critical {
           value 6;
           description
             "The 'critical' severity level indicates that a service
              affecting condition has occurred and an immediate
              corrective action is required.  Such a severity can be
              reported, for example, when a resource becomes totally out
              of service and its capability must be restored.";
         }
       }
       description
         "The severity level of the alarm.  Note well that value 'clear'
          is not included.  If an alarm is cleared or not is a separate
          boolean flag.";
       reference
         "ITU Recommendation X.733: Information Technology
            - Open Systems Interconnection
            - System Management: Alarm Reporting Function";
     }

     typedef severity-with-clear {
       type union {
         type enumeration {
           enum cleared {
             value 1;
             description
               "The alarm is cleared by the instrumentation.";
           }
         }
         type severity;
       }
       description
         "The severity level of the alarm including clear.  This is used

Vallin & Bjorklund      Expires October 13, 2019               [Page 29]
Internet-Draft              YANG Alarm Module                 April 2019

          only in notifications reporting state changes for an alarm.";
     }

     typedef writable-operator-state {
       type enumeration {
         enum none {
           value 1;
           description
             "The alarm is not being taken care of.";
         }
         enum ack {
           value 2;
           description
             "The alarm is being taken care of.  Corrective action not
              taken yet, or failed";
         }
         enum closed {
           value 3;
           description
             "Corrective action taken successfully.";
         }
       }
       description
         "Operator states on an alarm.  The 'closed' state indicates
          that an operator considers the alarm being resolved.  This is
          separate from the alarm's 'is-cleared' leaf.";
     }

     typedef operator-state {
       type union {
         type writable-operator-state;
         type enumeration {
           enum shelved {
             value 4;
             description
               "The alarm is shelved.  Alarms in /alarms/shelved-alarms/
                MUST be assigned this operator state by the server as
                the last entry in the operator-state-change list.  The
                text for that entry SHOULD include the shelf name.";
           }
           enum un-shelved {
             value 5;
             description
               "The alarm is moved back to 'alarm-list' from a shelf.
                Alarms that are moved from /alarms/shelved-alarms/ to
                /alarms/alarm-list MUST be assigned this state by the
                server as the last entry in the 'operator-state-change'
                list.  The text for that entry SHOULD include the shelf

Vallin & Bjorklund      Expires October 13, 2019               [Page 30]
Internet-Draft              YANG Alarm Module                 April 2019

                name.";
           }
         }
       }
       description
         "Operator states on an alarm.  The 'closed' state indicates
          that an operator considers the alarm being resolved.  This is
          separate from the alarm's 'is-cleared' leaf.";
     }

     /* Alarm type */

     typedef alarm-type-id {
       type identityref {
         base alarm-type-id;
       }
       description
         "Identifies an alarm type.  The description of the alarm type
          id MUST indicate if the alarm type is abstract or not.  An
          abstract alarm type is used as a base for other alarm type ids
          and will not be used as a value for an alarm or be present in
          the alarm inventory.";
     }

     typedef alarm-type-qualifier {
       type string;
       description
         "If an alarm type can not be fully specified at design time by
          alarm-type-id, this string qualifier is used in addition to
          fully define a unique alarm type.

          The definition of alarm qualifiers is considered being part of
          the instrumentation and out of scope for this module.  An
          empty string is used when this is part of a key.";
     }

     /*
      * Groupings
      */

     grouping common-alarm-parameters {
       description
         "Common parameters for an alarm.

          This grouping is used both in the alarm list and in the
          notification representing an alarm state change.";
       leaf resource {
         type resource;

Vallin & Bjorklund      Expires October 13, 2019               [Page 31]
Internet-Draft              YANG Alarm Module                 April 2019

         mandatory true;
         description
           "The alarming resource.  See also 'alt-resource'.  This could
            for example be a reference to the alarming interface";
       }
       leaf alarm-type-id {
         type alarm-type-id;
         mandatory true;
         description
           "This leaf and the leaf 'alarm-type-qualifier' together
            provides a unique identification of the alarm type.";
       }
       leaf alarm-type-qualifier {
         type alarm-type-qualifier;
         description
           "This leaf is used when the 'alarm-type-id' leaf cannot
            uniquely identify the alarm type.  Normally, this is not the
            case, and this leaf is the empty string.";
       }
       leaf-list alt-resource {
         type resource;
         description
           "Used if the alarming resource is available over other
            interfaces.  This field can contain SNMP OIDs, CIM paths or
            3GPP Distinguished names for example.";
       }
       list related-alarm {
         if-feature "alarm-correlation";
         key "resource alarm-type-id alarm-type-qualifier";
         description
           "References to related alarms.  Note that the related alarm
            might have been purged from the alarm list.";
         leaf resource {
           type leafref {
             path "/alarms/alarm-list/alarm/resource";
             require-instance false;
           }
           description
             "The alarming resource for the related alarm.";
         }
         leaf alarm-type-id {
           type leafref {
             path "/alarms/alarm-list/alarm"
                + "[resource=current()/../resource]"
                + "/alarm-type-id";
             require-instance false;
           }
           description

Vallin & Bjorklund      Expires October 13, 2019               [Page 32]
Internet-Draft              YANG Alarm Module                 April 2019

             "The alarm type identifier for the related alarm.";
         }
         leaf alarm-type-qualifier {
           type leafref {
             path "/alarms/alarm-list/alarm"
                + "[resource=current()/../resource]"
                + "[alarm-type-id=current()/../alarm-type-id]"
                + "/alarm-type-qualifier";
             require-instance false;
           }
           description
             "The alarm qualifier for the related alarm.";
         }
       }
       leaf-list impacted-resource {
         if-feature "service-impact-analysis";
         type resource;
         description
           "Resources that might be affected by this alarm.  If the
            system creates an alarm on a resource and also has a mapping
            to other resources that might be impacted, these resources
            can be listed in this leaf-list.  In this way the system can
            create one alarm instead of several.  For example, if an
            interface has an alarm, the 'impacted-resource' can
            reference the aggregated port channels.";
       }
       leaf-list root-cause-resource {
         if-feature "root-cause-analysis";
         type resource;
         description
           "Resources that are candidates for causing the alarm.  If the
            system has a mechanism to understand the candidate root
            causes of an alarm, this leaf-list can be used to list the
            root cause candidate resources.  In this way the system can
            create one alarm instead of several.  An example might be a
            logging system (alarm resource) that fails, the alarm can
            reference the file-system in the 'root-cause-resource'
            leaf-list.  Note that the intended use is not to also send
            an an alarm with the root-cause-resource as alarming
            resource.  The root-cause-resource leaf list is a hint and
            should not also generate an alarm for the same problem.";
       }
     }

     grouping alarm-state-change-parameters {
       description
         "Parameters for an alarm state change.

Vallin & Bjorklund      Expires October 13, 2019               [Page 33]
Internet-Draft              YANG Alarm Module                 April 2019

          This grouping is used both in the alarm list's status-change
          list and in the notification representing an alarm state
          change.";
       leaf time {
         type yang:date-and-time;
         mandatory true;
         description
           "The time the status of the alarm changed.  The value
            represents the time the real alarm state change appeared in
            the resource and not when it was added to the alarm
            list.  The /alarm-list/alarm/last-changed MUST be set to the
            same value.";
       }
       leaf perceived-severity {
         type severity-with-clear;
         mandatory true;
         description
           "The severity of the alarm as defined by X.733.  Note that
            this may not be the original severity since the alarm may
            have changed severity.";
         reference
           "ITU Recommendation X.733: Information Technology
              - Open Systems Interconnection
              - System Management: Alarm Reporting Function";
       }
       leaf alarm-text {
         type alarm-text;
         mandatory true;
         description
           "A user friendly text describing the alarm state change.";
         reference
           "ITU Recommendation X.733: Information Technology
              - Open Systems Interconnection
              - System Management: Alarm Reporting Function";
       }
     }

     grouping operator-parameters {
       description
         "This grouping defines parameters that can be changed by an
          operator.";
       leaf time {
         type yang:date-and-time;
         mandatory true;
         description
           "Timestamp for operator action on alarm.";
       }
       leaf operator {

Vallin & Bjorklund      Expires October 13, 2019               [Page 34]
Internet-Draft              YANG Alarm Module                 April 2019

         type string;
         mandatory true;
         description
           "The name of the operator that has acted on this alarm.";
       }
       leaf state {
         type operator-state;
         mandatory true;
         description
           "The operator's view of the alarm state.";
       }
       leaf text {
         type string;
         description
           "Additional optional textual information provided by the
            operator.";
       }
     }

     grouping resource-alarm-parameters {
       description
         "Alarm parameters that originates from the resource view.";
       leaf is-cleared {
         type boolean;
         mandatory true;
         description
           "Indicates the current clearance state of the alarm.  An
            alarm might toggle from active alarm to cleared alarm and
            back to active again.";
       }
       leaf last-raised {
         type yang:date-and-time;
         mandatory true;
         description
           "An alarm may change severity level and toggle between
            active and cleared during its life-time. This leaf indicates
            the last time it was last raised (is-cleared = false).";
       }
       leaf last-changed {
         type yang:date-and-time;
         mandatory true;
         description
           "A timestamp when the 'status-change' or
            'operator-state-change' list was last changed.";
       }
       leaf perceived-severity {
         type severity;
         mandatory true;

Vallin & Bjorklund      Expires October 13, 2019               [Page 35]
Internet-Draft              YANG Alarm Module                 April 2019

         description
           "The last severity of the alarm.

            If an alarm was raised with severity 'warning', but later
            changed to 'major', this leaf will show 'major'.";
       }
       leaf alarm-text {
         type alarm-text;
         mandatory true;
         description
           "The last reported alarm text.  This text should contain
            information for an operator to be able to understand the
            problem and how to resolve it.";
       }
       list status-change {
         if-feature "alarm-history";
         key "time";
         min-elements 1;
         description
           "A list of status change events for this alarm.

            The entry with latest time-stamp in this list MUST
            correspond to the leafs 'is-cleared', 'perceived-severity'
            and 'alarm-text' for the alarm.

            This list is ordered according to the timestamps of alarm
            state changes.  The first item corresponds to the latest
            state change.

            The following state changes creates an entry in this
            list:
            - changed severity (warning, minor, major, critical)
            - clearance status, this also updates the 'is-cleared'
              leaf
            - alarm text update";
         uses alarm-state-change-parameters;
       }
     }

     grouping filter-input {
       description
         "Grouping to specify a filter construct on alarm information.";
       leaf alarm-clearance-status {
         type enumeration {
           enum any {
             description
               "Ignore alarm clearance status.";
           }

Vallin & Bjorklund      Expires October 13, 2019               [Page 36]
Internet-Draft              YANG Alarm Module                 April 2019

           enum cleared {
             description
               "Filter cleared alarms.";
           }
           enum not-cleared {
             description
               "Filter not cleared alarms.";
           }
         }
         mandatory true;
         description
           "The clearance status of the alarm.";
       }
       container older-than {
         presence "Age specification";
         description
           "Matches the 'last-status-change' leaf in the alarm.";
         choice age-spec {
           description
             "Filter using date and time age.";
           case seconds {
             leaf seconds {
               type uint16;
               description
                 "Age expressed in seconds.";
             }
           }
           case minutes {
             leaf minutes {
               type uint16;
               description
                 "Age expressed in minutes.";
             }
           }
           case hours {
             leaf hours {
               type uint16;
               description
                 "Age expressed in hours.";
             }
           }
           case days {
             leaf days {
               type uint16;
               description
                 "Age expressed in days.";
             }
           }

Vallin & Bjorklund      Expires October 13, 2019               [Page 37]
Internet-Draft              YANG Alarm Module                 April 2019

           case weeks {
             leaf weeks {
               type uint16;
               description
                 "Age expressed in weeks.";
             }
           }
         }
       }
       container severity {
         presence "Severity filter";
         choice sev-spec {
           description
             "Filter based on severity level.";
           leaf below {
             type severity;
             description
               "Severity less than this leaf.";
           }
           leaf is {
             type severity;
             description
               "Severity level equal this leaf.";
           }
           leaf above {
             type severity;
             description
               "Severity level higher than this leaf.";
           }
         }
         description
           "Filter based on severity.";
       }
       container operator-state-filter {
         if-feature "operator-actions";
         presence "Operator state filter";
         leaf state {
           type operator-state;
           description
             "Filter on operator state.";
         }
         leaf user {
           type string;
           description
             "Filter based on which operator.";
         }
         description
           "Filter based on operator state.";

Vallin & Bjorklund      Expires October 13, 2019               [Page 38]
Internet-Draft              YANG Alarm Module                 April 2019

       }
     }

     /*
      * The /alarms data tree
      */

     container alarms {
       description
         "The top container for this module.";
       container control {
         description
           "Configuration to control the alarm behavior.";
         leaf max-alarm-status-changes {
           type union {
             type uint16;
             type enumeration {
               enum infinite {
                 description
                   "The status change entries are accumulated
                    infinitely.";
               }
             }
           }
           default "32";
           description
             "The status-change entries are kept in a circular list per
              alarm.  When this number is exceeded, the oldest status
              change entry is automatically removed.  If the value is
              'infinite', the status change entries are accumulated
              infinitely.";
         }
         leaf notify-status-changes {
           type enumeration {
             enum all-state-changes {
               description
                 "Send notifications for all status changes.";
             }
             enum raise-and-clear {
               description
                 "Send notifications only for raise, clear, and
                  re-raise.  Notifications for severity level changes or
                  alarm text changes are not sent.";
             }
             enum severity-level {
               description
                 "Only send notifications for alarm state changes
                  crossing the level specified in

Vallin & Bjorklund      Expires October 13, 2019               [Page 39]
Internet-Draft              YANG Alarm Module                 April 2019

                  'notify-severity-level'.  Always send clear
                  notifications.";
             }
           }
           must '. != "severity-level" or ../notify-severity-level' {
             description
               "When notify-status-changes is 'severity-level', a value
                must be given for notify-severity-level.";
           }
           default "all-state-changes";
           description
             "This leaf controls the notifications sent for alarm status
              updates.  There are three options:

              1.  Notifications are sent for all updates, severity level
                 changes and alarm text changes

              2.  Notifications are only sent for alarm raise and clear

              3.  Notifications are sent for status changes equal to or
                 above the specified severity level.  Clear
                 notifications shall always be sent. Notifications shall
                 also be sent for state changes that makes an alarm less
                 severe than the specified level.

              For example, in option 3, assuming the severity level is
              set to major and that the alarm has the following state
              changes:

              [(Time, severity, clear)]:
              [(T1, major, -), (T2, minor, -), (T3, warning, -),
               (T4, minor, -), (T5, major, -), (T6, critical, -),
               (T7, major.  -), (T8, major, clear)]

              In that case, notifications will be sent at times
              T1, T2, T5, T6, T7 and T8.";
         }
         leaf notify-severity-level {
           when '../notify-status-changes = "severity-level"';
           type severity;
           description
             "Only send notifications for alarm state changes crossing
              the specified level.  Always send clear notifications.";
         }
         container alarm-shelving {
           if-feature "alarm-shelving";
           description
             "The alarm-shelving/shelf list is used to shelve

Vallin & Bjorklund      Expires October 13, 2019               [Page 40]
Internet-Draft              YANG Alarm Module                 April 2019

              (block/filter) alarms.  The conditions in the shelf
              criteria are logically ANDed.  The first matching shelf is
              used, and an alarm is shelved only for this first match.
              Matching alarms MUST appear in the
              /alarms/shelved-alarms/shelved-alarm list, and
              non-matching /alarms MUST appear in the
              /alarms/alarm-list/alarm list.  The server does not send
              any notifications for shelved alarms.

              The server MUST maintain states (e.g., severity
              changes) for the shelved alarms.

              Alarms that match the criteria shall have an
              operator state 'shelved'.  When the shelf
              configuration removes an alarm from the shelf the server
              shall add an operator state 'un-shelved'.";
           list shelf {
             key "name";
             ordered-by user;
             leaf name {
               type string;
               description
                 "An arbitrary name for the alarm shelf.";
             }
             description
               "Each entry defines the criteria for shelving alarms.
                Criteria are ANDed.  If no criteria are specified,
                all alarms will be shelved.";
             leaf-list resource {
               type resource-match;
               description
                 "Shelve alarms for matching resources.";
             }
             list alarm-type {
               key "alarm-type-id alarm-type-qualifier-match";
               description
                 "Any alarm matching the combined criteria of
                  alarm-type-id and alarm-type-qualifier-match
                  MUST be matched.";
               leaf alarm-type-id {
                 type alarm-type-id;
                 description
                   "Shelve all alarms that have an alarm-type-id that is
                    equal to or derived from the given alarm-type-id.";
               }
               leaf alarm-type-qualifier-match {
                 type string;
                 description

Vallin & Bjorklund      Expires October 13, 2019               [Page 41]
Internet-Draft              YANG Alarm Module                 April 2019

                   "An XML Schema regular expression that is used to
                    match an alarm type qualifier.  Shelve all alarms
                    that matches this regular expression for the alarm
                    type qualifier.";
                 reference
                   "XML Schema Part 2: Datatypes Second Edition,
                      World Wide Web Consortium Recommendation
                      REC-xmlschema-2-20041028";
               }
             }
             leaf description {
               type string;
               description
                 "An optional textual description of the shelf.  This
                  description should include the reason for shelving
                  these alarms.";
             }
           }
         }
       }
       container alarm-inventory {
         config false;
         description
           "This alarm-inventory/alarm-type list contains all possible
            alarm types for the system.

            If the system knows for which resources a specific alarm
            type can appear, this is also identified in the inventory.
            The list also tells if each alarm type has a corresponding
            clear state.  The inventory shall only contain concrete
            alarm types.

            The alarm inventory MUST be updated by the system when new
            alarms can appear.  This can be the case when installing new
            software modules or inserting new card types.  A
            notification 'alarm-inventory-changed' is sent when the
            inventory is changed.";
         list alarm-type {
           key "alarm-type-id alarm-type-qualifier";
           description
             "An entry in this list defines a possible alarm.";
           leaf alarm-type-id {
             type alarm-type-id;
             description
               "The statically defined alarm type identifier for this
                possible alarm.";
           }
           leaf alarm-type-qualifier {

Vallin & Bjorklund      Expires October 13, 2019               [Page 42]
Internet-Draft              YANG Alarm Module                 April 2019

             type alarm-type-qualifier;
             description
               "The optionally dynamically defined alarm type identifier
                for this possible alarm.";
           }
           leaf-list resource {
             type resource-match;
             description
               "Optionally, specifies for which resources the alarm type
                is valid.";
           }
           leaf will-clear {
             type boolean;
             mandatory true;
             description
               "This leaf tells the operator if the alarm will be
                cleared when the correct corrective action has been
                taken.  Implementations SHOULD strive for detecting the
                cleared state for all alarm types.

                If this leaf is 'true', the operator can monitor the
                alarm until it becomes cleared after the corrective
                action has been taken.

                If this leaf is 'false', the operator needs to validate
                that the alarm is no longer active using other
                mechanisms.  Alarms can lack a corresponding clear due
                to missing instrumentation or that there is no logical
                corresponding clear state.";
           }
           leaf-list severity-levels {
             type severity;
             description
               "This leaf-list indicates the possible severity levels of
                this alarm type.  Note well that 'clear' is not part of
                the severity type.  In general, the severity level
                should be defined by the instrumentation based on
                dynamic state and not defined statically by the alarm
                type in order to provide relevant severity level based
                on dynamic state and context.  However most alarm types
                have a defined set of possible severity levels and this
                should be provided here.";
           }
           leaf description {
             type string;
             mandatory true;
             description
               "A description of the possible alarm.  It SHOULD include

Vallin & Bjorklund      Expires October 13, 2019               [Page 43]
Internet-Draft              YANG Alarm Module                 April 2019

                information on possible underlying root causes and
                corrective actions.";
           }
         }
       }
       container summary {
         if-feature "alarm-summary";
         config false;
         description
           "This container gives a summary of number of alarms.";
         list alarm-summary {
           key "severity";
           description
             "A global summary of all alarms in the system.  The summary
              does not include shelved alarms.";
           leaf severity {
             type severity;
             description
               "Alarm summary for this severity level.";
           }
           leaf total {
             type yang:gauge32;
             description
               "Total number of alarms of this severity level.";
           }
           leaf not-cleared {
             type yang:gauge32;
             description
               "Total number of alarms of this severity level
                that are not cleared.";
           }
           leaf cleared {
             type yang:gauge32;
             description
               "For this severity level, the number of alarms that are
                cleared.";
           }
           leaf cleared-not-closed {
             if-feature "operator-actions";
             type yang:gauge32;
             description
               "For this severity level, the number of alarms that are
                cleared but not closed.";
           }
           leaf cleared-closed {
             if-feature "operator-actions";
             type yang:gauge32;
             description

Vallin & Bjorklund      Expires October 13, 2019               [Page 44]
Internet-Draft              YANG Alarm Module                 April 2019

               "For this severity level, the number of alarms that are
                cleared and closed.";
           }
           leaf not-cleared-closed {
             if-feature "operator-actions";
             type yang:gauge32;
             description
               "For this severity level, the number of alarms that are
                not cleared but closed.";
           }
           leaf not-cleared-not-closed {
             if-feature "operator-actions";
             type yang:gauge32;
             description
               "For this severity level, the number of alarms that are
                not cleared and not closed.";
           }
         }
         leaf shelves-active {
           if-feature "alarm-shelving";
           type empty;
           description
             "This is a hint to the operator that there are active
              alarm shelves.  This leaf MUST exist if the
              /alarms/shelved-alarms/number-of-shelved-alarms is > 0.";
         }
       }
       container alarm-list {
         config false;
         description
           "The alarms in the system.";
         leaf number-of-alarms {
           type yang:gauge32;
           description
             "This object shows the total number of
              alarms in the system, i.e., the total number
              of entries in the alarm list.";
         }
         leaf last-changed {
           type yang:date-and-time;
           description
             "A timestamp when the alarm list was last
              changed.  The value can be used by a manager to
              initiate an alarm resynchronization procedure.";
         }
         list alarm {
           key "resource alarm-type-id alarm-type-qualifier";
           description

Vallin & Bjorklund      Expires October 13, 2019               [Page 45]
Internet-Draft              YANG Alarm Module                 April 2019

             "The list of alarms.  Each entry in the list holds one
              alarm for a given alarm type and resource.  An alarm can
              be updated from the underlying resource or by the user.
              The following leafs are maintained by the resource:
              is-cleared, last-change, perceived-severity, and
              alarm-text.  An operator can change: operator-state and
              operator-text.

              Entries appear in the alarm list the first time an alarm
              becomes active for a given alarm-type and resource.
              Entries do not get deleted when the alarm is cleared.
              Clear status is represented as a boolean flag.

              Alarm entries are removed, purged, from the list by an
              explicit purge action.  For example, purge all alarms that
              are cleared and in closed operator-state that are older
              than 24 hours.  Purged alarms are removed from the alarm
              list.  If the alarm resource state changes after a purge,
              the alarm will reappear in the alarm list.

              Systems may also remove alarms based on locally configured
              policies which is out of scope for this module.";
           uses common-alarm-parameters;
           leaf time-created {
             type yang:date-and-time;
             mandatory true;
             description
               "The time-stamp when this alarm entry was created.  This
                represents the first time the alarm appeared, it can
                also represent that the alarm re-appeared after a purge.
                Further state-changes of the same alarm does not change
                this leaf, these changes will update the 'last-changed'
                leaf.";
           }
           uses resource-alarm-parameters;
           list operator-state-change {
             if-feature "operator-actions";
             key "time";
             description
               "This list is used by operators to indicate the state of
                human intervention on an alarm.  For example, if an
                operator has seen an alarm, the operator can add a new
                item to this list indicating that the alarm is
                acknowledged.";
             uses operator-parameters;
           }
           action set-operator-state {
             if-feature "operator-actions";

Vallin & Bjorklund      Expires October 13, 2019               [Page 46]
Internet-Draft              YANG Alarm Module                 April 2019

             description
               "This is a means for the operator to indicate the level
                of human intervention on an alarm.";
             input {
               leaf state {
                 type writable-operator-state;
                 mandatory true;
                 description
                   "Set this operator state.";
               }
               leaf text {
                 type string;
                 description
                   "Additional optional textual information.";
               }
             }
           }
           notification operator-action {
             if-feature "operator-actions";
             description
               "This notification is used to report that an operator
                acted upon an alarm.";
             uses operator-parameters;
           }
         }
         action purge-alarms {
           description
             "This operation requests the server to delete entries from
              the alarm list according to the supplied criteria.

              Typically this operation is used to delete alarms that are
              in closed operator state and older than a specified time.

              The number of purged alarms is returned as an output
              parameter.";
           input {
             uses filter-input;
           }
           output {
             leaf purged-alarms {
               type uint32;
               description
                 "Number of purged alarms.";
             }
           }
         }
         action compress-alarms {
           if-feature "alarm-history";

Vallin & Bjorklund      Expires October 13, 2019               [Page 47]
Internet-Draft              YANG Alarm Module                 April 2019

           description
             "This operation requests the server to compress entries in
              the alarm list by removing all but the latest
              'status-change' entry for all matching alarms.  Conditions
              in the input are logically ANDed.  If no input condition
              is given, all alarms are compressed.";
           input {
             leaf resource {
               type resource-match;
               description
                 "Compress the alarms matching this resource.";
             }
             leaf alarm-type-id {
               type leafref {
                 path "/alarms/alarm-list/alarm/alarm-type-id";
                 require-instance false;
               }
               description
                 "Compress alarms with this alarm-type-id.";
             }
             leaf alarm-type-qualifier {
               type leafref {
                 path "/alarms/alarm-list/alarm/alarm-type-qualifier";
                 require-instance false;
               }
               description
                 "Compress the alarms with this alarm-type-qualifier.";
             }
           }
           output {
             leaf compressed-alarms {
               type uint32;
               description
                 "Number of compressed alarm entries.";
             }
           }
         }
       }
       container shelved-alarms {
         if-feature "alarm-shelving";
         config false;
         description
           "The shelved alarms.  Alarms appear here if they match the
            criteria in /alarms/control/alarm-shelving.  This list does
            not generate any notifications.  The list represents alarms
            that are considered not relevant by the operator.  Alarms in
            this list have an operator-state of 'shelved'.  This can not
            be changed.";

Vallin & Bjorklund      Expires October 13, 2019               [Page 48]
Internet-Draft              YANG Alarm Module                 April 2019

         leaf number-of-shelved-alarms {
           type yang:gauge32;
           description
             "This object shows the total number of currently
              alarms, i.e., the total number of entries
              in the alarm list.";
         }
         leaf shelved-alarms-last-changed {
           type yang:date-and-time;
           description
             "A timestamp when the shelved alarm list was last changed.
              The value can be used by a manager to initiate an alarm
              resynchronization procedure.";
         }
         list shelved-alarm {
           key "resource alarm-type-id alarm-type-qualifier";
           description
             "The list of shelved alarms.  Shelved alarms can only be
              updated from the underlying resource, no operator actions
              are supported.";
           uses common-alarm-parameters;
           leaf shelf-name {
             type leafref {
               path "/alarms/control/alarm-shelving/shelf/name";
               require-instance false;
             }
             description
               "The name of the shelf.";
           }
           uses resource-alarm-parameters;
           list operator-state-change {
             if-feature "operator-actions";
             key "time";
             description
               "This list is used by operators to indicate the state of
                human intervention on an alarm.  For shelved alarms, the
                system has set the list item in the list to 'shelved'.";
             uses operator-parameters;
           }
         }
         action purge-shelved-alarms {
           description
             "This operation requests the server to delete entries from
              the shelved alarms list according to the supplied
              criteria.

              In the shelved alarm list it makes sense to delete alarms
              that are not relevant anymore.

Vallin & Bjorklund      Expires October 13, 2019               [Page 49]
Internet-Draft              YANG Alarm Module                 April 2019

              The number of purged alarms is returned as an output
              parameter.";
           input {
             uses filter-input;
           }
           output {
             leaf purged-alarms {
               type uint32;
               description
                 "Number of purged alarms.";
             }
           }
         }
         action compress-shelved-alarms {
           if-feature "alarm-history";
           description
             "This operation requests the server to compress entries in
              the shelved alarm list by removing all but the latest
              'status-change' entry for all matching shelved alarms.
              Conditions in the input are logically ANDed.  If no input
              condition is given, all alarms are compressed.";
           input {
             leaf resource {
               type leafref {
                 path "/alarms/shelved-alarms/shelved-alarm/resource";
                 require-instance false;
               }
               description
                 "Compress the alarms with this resource.";
             }
             leaf alarm-type-id {
               type leafref {
                 path "/alarms/shelved-alarms/shelved-alarm"
                    + "/alarm-type-id";
                 require-instance false;
               }
               description
                 "Compress alarms with this alarm-type-id.";
             }
             leaf alarm-type-qualifier {
               type leafref {
                 path "/alarms/shelved-alarms/shelved-alarm"
                    + "/alarm-type-qualifier";
                 require-instance false;
               }
               description
                 "Compress the alarms with this alarm-type-qualifier.";
             }

Vallin & Bjorklund      Expires October 13, 2019               [Page 50]
Internet-Draft              YANG Alarm Module                 April 2019

           }
           output {
             leaf compressed-alarms {
               type uint32;
               description
                 "Number of compressed alarm entries.";
             }
           }
         }
       }
       list alarm-profile {
         if-feature "alarm-profile";
         key "alarm-type-id alarm-type-qualifier-match resource";
         ordered-by user;
         description
           "This list is used to assign further information or
            configuration for each alarm type.  This module supports a
            mechanism where the client can override the system default
            alarm severity levels.  The alarm-profile is also a useful
            augmentation point for specific additions to alarm types.";
         leaf alarm-type-id {
           type alarm-type-id;
           description
             "The alarm type identifier to match.";
         }
         leaf alarm-type-qualifier-match {
           type string;
           description
             "An XML Schema regular expression that is used to match the
              alarm type qualifier.";
           reference
             "XML Schema Part 2: Datatypes Second Edition,
                World Wide Web Consortium Recommendation
                REC-xmlschema-2-20041028";
         }
         leaf resource {
           type resource-match;
           description
             "Specifies which resources to match.";
         }
         leaf description {
           type string;
           mandatory true;
           description
             "A description of the alarm profile.";
         }
         container alarm-severity-assignment-profile {
           if-feature "severity-assignment";

Vallin & Bjorklund      Expires October 13, 2019               [Page 51]
Internet-Draft              YANG Alarm Module                 April 2019

           description
             "The client can override the system default severity
              level.";
           reference
             "ITU M.3100, ITU M.3160
              - Generic Network Information Model, Alarm Severity
                Assignment Profile";
           leaf-list severity-levels {
             type severity;
             ordered-by user;
             description
               "Specifies the configured severity level(s) for the
                matching alarm.  If the alarm has several severity
                levels the leaf-list shall be given in rising severity
                order.  The original M3100/M3160 ASAP function only
                allows for a one-to-one mapping between alarm type and
                severity but since the IETF alarm module supports
                stateful alarms the mapping must allow for several
                severity levels.

                Assume a high-utilization alarm type with two thresholds
                with the system default severity levels of threshold1 =
                warning and threshold2 = minor.  Setting this leaf-list
                to (minor, major) will assign the severity levels
                threshold1 = minor and threshold2 = major";
           }
         }
       }
     }

     /*
      * Notifications
      */

     notification alarm-notification {
       description
         "This notification is used to report a state change for an
          alarm.  The same notification is used for reporting a newly
          raised alarm, a cleared alarm or changing the text and/or
          severity of an existing alarm.";
       uses common-alarm-parameters;
       uses alarm-state-change-parameters;
     }

     notification alarm-inventory-changed {
       description
         "This notification is used to report that the list of possible
          alarms has changed.  This can happen when for example if a new

Vallin & Bjorklund      Expires October 13, 2019               [Page 52]
Internet-Draft              YANG Alarm Module                 April 2019

          software module is installed, or a new physical card is
          inserted.";
     }
   }

   <CODE ENDS>

7.  X.733 Extensions

   Many alarm systems are based on the X.733, [X.733], and X.736 [X.736]
   alarm standards.  This module augments the alarm inventory, the alarm
   lists and the alarm notification with X.733 and X.736 parameters.

   The module also supports a feature whereby the alarm manager can
   configure the mapping from alarm types to X.733 "event-type" and
   "probable-cause" parameters.  This might be needed when the default
   mapping provided by the system is in conflict with other management
   systems or not considered correct.

   Note that the IETF Alarm Module term "resource" is synonymous to the
   ITU term "managed object".

8.  The X.733 Mapping Module

   This YANG module references [X.721], [X.733] and [X.736].

   <CODE BEGINS> file "ietf-alarms-x733@2019-03-21.yang"
   module ietf-alarms-x733 {
     yang-version 1.1;
     namespace "urn:ietf:params:xml:ns:yang:ietf-alarms-x733";
     prefix x733;

     import ietf-alarms {
       prefix al;
     }
     import ietf-yang-types {
       prefix yang;
       reference
         "RFC 6991: Common YANG Data Types";
     }

     organization
       "IETF CCAMP Working Group";
     contact
       "WG Web:   <http://tools.ietf.org/wg/ccamp>
        WG List:  <mailto:ccamp@ietf.org>

        Editor:   Stefan Vallin

Vallin & Bjorklund      Expires October 13, 2019               [Page 53]
Internet-Draft              YANG Alarm Module                 April 2019

                  <mailto:stefan@wallan.se>

        Editor:   Martin Bjorklund
                  <mailto:mbj@tail-f.com>";
     description
       "This module augments the ietf-alarms module with X.733 alarm
        parameters.

        The following structures are augmented with X.733 event type
        and probable cause:

         1) alarms/alarm-inventory: all possible alarm types
         2) alarms/alarm-list: every alarm in the system
         3) alarm-notification: notifications indicating alarm state
            changes
         4) alarms/shelved-alarms

        The module also optionally allows the alarm management system
        to configure the mapping from the IETF Alarm module alarm keys
        to the ITU tuple (event-type, probable-cause).

        The mapping does not include a corresponding X.733 specific
        problem value. The recommendation is to use the
        'alarm-type-qualifier' leaf which serves the same purpose.

        The module uses an integer and a corresponding string for
        probable cause instead of a globally defined enumeration, in
        order to be able to manage conflicting enumeration definitions.
        A single globally defined enumeration is challenging to
        maintain.

        The key words 'MUST', 'MUST NOT', 'REQUIRED', 'SHALL', 'SHALL
        NOT', 'SHOULD', 'SHOULD NOT', 'RECOMMENDED', 'NOT RECOMMENDED',
        'MAY', and 'OPTIONAL' in this document are to be interpreted as
        described in BCP 14 (RFC 2119) (RFC 8174) when, and only when,
        they appear in all capitals, as shown here.

        Copyright (c) 2019 IETF Trust and the persons identified as
        authors of the code.  All rights reserved.

        Redistribution and use in source and binary forms, with or
        without modification, is permitted pursuant to, and subject to
        the license terms contained in, the Simplified BSD License set
        forth in Section 4.c of the IETF Trust's Legal Provisions
        Relating to IETF Documents
        (https://trustee.ietf.org/license-info).

        This version of this YANG module is part of RFC XXXX

Vallin & Bjorklund      Expires October 13, 2019               [Page 54]
Internet-Draft              YANG Alarm Module                 April 2019

        (https://tools.ietf.org/html/rfcXXXX); see the RFC itself for
        full legal notices.";
     reference
       "ITU Recommendation X.733: Information Technology
          - Open Systems Interconnection
          - System Management: Alarm Reporting Function";

     revision 2019-03-21 {
       description
         "Initial revision.";
       reference
         "RFC XXXX: YANG Alarm Module";
     }

     /*
      * Features
      */

     feature configure-x733-mapping {
       description
         "The system supports configurable X733 mapping from
          the IETF alarm module alarm-type to X733 event-type
          and probable-cause.";
     }

     /*
      * Typedefs
      */

     typedef event-type {
       type enumeration {
         enum other {
           value 1;
           description
             "None of the below.";
         }
         enum communications-alarm {
           value 2;
           description
             "An alarm of this type is principally associated with the
              procedures and/or processes required to convey
              information from one point to another.";
         }
         enum quality-of-service-alarm {
           value 3;
           description
             "An alarm of this type is principally associated with a
              degradation in the quality of a service.";

Vallin & Bjorklund      Expires October 13, 2019               [Page 55]
Internet-Draft              YANG Alarm Module                 April 2019

         }
         enum processing-error-alarm {
           value 4;
           description
             "An alarm of this type is principally associated with a
              software or processing fault.";
         }
         enum equipment-alarm {
           value 5;
           description
             "An alarm of this type is principally associated with an
              equipment fault.";
         }
         enum environmental-alarm {
           value 6;
           description
             "An alarm of this type is principally associated with a
              condition relating to an enclosure in which the equipment
              resides.";
         }
         enum integrity-violation {
           value 7;
           description
             "An indication that information may have been illegally
              modified, inserted or deleted.";
         }
         enum operational-violation {
           value 8;
           description
             "An indication that the provision of the requested service
              was not possible due to the unavailability, malfunction or
              incorrect invocation of the service.";
         }
         enum physical-violation {
           value 9;
           description
             "An indication that a physical resource has been violated
              in a way that suggests a security attack.";
         }
         enum security-service-or-mechanism-violation {
           value 10;
           description
             "An indication that a security attack has been detected by
              a security service or mechanism.";
         }
         enum time-domain-violation {
           value 11;
           description

Vallin & Bjorklund      Expires October 13, 2019               [Page 56]
Internet-Draft              YANG Alarm Module                 April 2019

             "An indication that an event has occurred at an unexpected
              or prohibited time.";
         }
       }
       description
         "The event types as defined by X.733 and X.736.";
       reference
         "ITU Recommendation X.733: Information Technology
            - Open Systems Interconnection
            - System Management: Alarm Reporting Function
          ITU Recommendation X.736: Information Technology
            - Open Systems Interconnection
            - System Management: Security Alarm Reporting Function";
     }

     typedef trend {
       type enumeration {
         enum less-severe {
           description
             "There is at least one outstanding alarm of a
              severity higher (more severe) than that in the
              current alarm.";
         }
         enum no-change {
           description
             "The Perceived severity reported in the current
              alarm is the same as the highest (most severe)
              of any of the outstanding alarms";
         }
         enum more-severe {
           description
             "The Perceived severity in the current alarm is
              higher (more severe) than that reported in any
              of the outstanding alarms.";
         }
       }
       description
         "This type is used to describe the
          severity trend of the alarming resource";
       reference
         "ITU Recommendation X.721: Information Technology
             - Open Systems Interconnection
             - Structure of management information:
               Definition of management information
          Module Attribute-ASN1Module";
     }

     typedef value-type {

Vallin & Bjorklund      Expires October 13, 2019               [Page 57]
Internet-Draft              YANG Alarm Module                 April 2019

       type union {
         type int64;
         type uint64;
         type decimal64 {
           fraction-digits 2;
         }
       }
       description
         "A generic union type to match ITU choice of integer
          and real.";
     }

     /*
      * Groupings
      */

     grouping x733-alarm-parameters {
       description
         "Common X.733 parameters for alarms.";
       leaf event-type {
         type event-type;
         description
           "The X.733/X.736 event type for this alarm.";
       }
       leaf probable-cause {
         type uint32;
         description
           "The X.733 probable cause for this alarm.";
       }
       leaf probable-cause-string {
         type string;
         description
           "The user friendly string matching
            the probable cause integer value. The string
            SHOULD match the X.733 enumeration. For example,
            value 27 is 'localNodeTransmissionError'.";
       }
       container threshold-information {
         description
           "This parameter shall be present when the alarm
            is a result of crossing a threshold. ";
         leaf triggered-threshold {
           type string;
           description
             "The identifier of the threshold attribute that
              caused the notification.";
         }
         leaf observed-value {

Vallin & Bjorklund      Expires October 13, 2019               [Page 58]
Internet-Draft              YANG Alarm Module                 April 2019

           type value-type;
           description
             "The value of the gauge or counter which crossed
              the threshold. This may be different from the
              threshold value if, for example, the gauge may
              only take on discrete values.";
         }
         choice threshold-level {
           description
             "In the case of a gauge the threshold level specifies
              a pair of threshold values, the first being the value
              of the crossed threshold and the second, its corresponding
              hysteresis; in the case of a counter the threshold level
              specifies only the threshold value.";
           case up {
             leaf up-high {
               type value-type;
               description
                 "The going up threshold for rising the alarm.";
             }
             leaf up-low {
               type value-type;
               description
                 "The threshold level for clearing the alarm.
                  This is used for hysteresis functions for gauges.";
             }
           }
           case down {
             leaf down-low {
               type value-type;
               description
                 "The going down threshold for rising the alarm.";
             }
             leaf down-high {
               type value-type;
               description
                 "The threshold level for clearing the alarm.
                  This is used for hysteresis functions for gauges.";
             }
           }
         }
         leaf arm-time {
           type yang:date-and-time;
           description
             "For a gauge threshold, the time at which the threshold
              was last re-armed, namely the time after the previous
              threshold crossing at which the hysteresis value of the
              threshold was exceeded thus again permitting generation

Vallin & Bjorklund      Expires October 13, 2019               [Page 59]
Internet-Draft              YANG Alarm Module                 April 2019

              of notifications when the threshold is crossed.
              For a counter threshold, the later of the time at which
              the threshold offset was last applied, or the time at
              which the counter was last initialized (for resettable
              counters).";
         }
       }
       list monitored-attributes {
         uses attribute;
         key "id";
         description
           "The Monitored attributes parameter, when present, defines
            one or more attributes of the resource and their
            corresponding values at the time of the alarm.";
       }
       leaf-list proposed-repair-actions {
         type string;
         description
           "This parameter, when present, is used if the cause is
            known and the system being managed can suggest one or
            more solutions (such as switch in standby equipment,
            retry, replace media).";
       }
       leaf trend-indication {
         type trend;
         description
           "This parameter specifies the current
            severity trend of the resource. If present it
            indicates that there are one or more alarms
            ('outstanding alarms') which have not been cleared,
            and pertain to the same resource as that to which
            this alarm ('current alarm') pertains.
            The possible values are:

              more-severe: The Perceived severity in the current
                alarm is higher (more severe) than that reported in
                any of the outstanding alarms.

              no-change: The Perceived severity reported in the
                current alarm is the same as the highest (most severe)
                of any of the outstanding alarms.

              less-severe: There is at least one outstanding alarm
                of a severity higher (more severe) than that in the
                current alarm.";
       }
       leaf backedup-status {
         type boolean;

Vallin & Bjorklund      Expires October 13, 2019               [Page 60]
Internet-Draft              YANG Alarm Module                 April 2019

         description
           "This parameter, when present, specifies whether or not
            the object emitting the alarm has been backed-up, and
            services provided to the user have, therefore, not been
            disrupted. The use of this field in conjunction with the
            severity field provides information in an independent form
            to qualify the seriousness of the alarm and the ability of
            the system as a whole to continue to provide services.
            If the value of this parameter is true, it indicates that
            the object emitting the alarm has been backed-up; if false,
            the object has not been backed-up.";
       }
       leaf backup-object {
         type al:resource;
         description
           "This parameter shall be present when the Backed-up status
            parameter is present and has the value true. This parameter
            specifies the managed object instance that is providing
            back-up services for the managed object about which the
            notification pertains. This parameter is useful,
            for example, when the back-up object is from a pool of
            objects any of which may be dynamically allocated to
            replace a faulty object.";
       }
       list additional-information {
         key "identifier";
         description
           "This parameter allows the inclusion of a
            set of additional information in the alarm. It is
            a series of data structures each of which contains three
            items of information: an identifier, a significance
            indicator, and the problem information.";
         leaf identifier {
           type string;
           description
             "Identifies the data-type of the information parameter.";
         }
         leaf significant {
           type boolean;
           description
             "Set to true if the receiving system must be able to
              parse the contents of the information subparameter
              for the event report to be fully understood.";
         }
         leaf information {
           type string;
           description
             "Additional information about the alarm.";

Vallin & Bjorklund      Expires October 13, 2019               [Page 61]
Internet-Draft              YANG Alarm Module                 April 2019

         }
       }
       leaf security-alarm-detector {
         type al:resource;
         description
           "This parameter identifies the detector of the security
            alarm.";
       }
       leaf service-user {
         type al:resource;
         description
           "This parameter identifies the service-user whose request
            for service led to the generation of the security alarm.";
       }
       leaf service-provider {
         type al:resource;
         description
           "This parameter identifies the intended service-provider
            of the service that led to the generation of the security
            alarm.";
       }
       reference
         "ITU Recommendation X.733: Information Technology
            - Open Systems Interconnection
            - System Management: Alarm Reporting Function
          ITU Recommendation X.736: Information Technology
            - Open Systems Interconnection
            - System Management: Security Alarm Reporting Function";
     }

     grouping x733-alarm-definition-parameters {
       description
         "Common X.733 parameters for alarm definitions.
          This grouping is used to define those alarm
          attributes that can be mapped from the alarm-type
          mechanism in the ietf-alarm module.";
       leaf event-type {
         type event-type;
         description
           "The alarm type has this X.733/X.736 event type.";
       }
       leaf probable-cause {
         type uint32;
         description
           "The alarm type has this X.733 probable cause value.
            This module defines probable cause as an integer
            and not as an enumeration.  The reason being that the
            primary use of probable cause is in the management

Vallin & Bjorklund      Expires October 13, 2019               [Page 62]
Internet-Draft              YANG Alarm Module                 April 2019

            application if it is based on the X.733 standard.
            However, most management applications have their own
            defined enum definitions and merging enums from
            different systems might create conflicts.  By using
            a configurable uint32 the system can be configured
            to match the enum values in the management application.";
       }
       leaf probable-cause-string {
         type string;
         description
           "This string can be used to give a user friendly string
            to the probable cause value.";
       }
     }

     grouping attribute {
       description
         "A grouping to match the ITU generic reference to
          an attribute.";
       leaf id {
         type al:resource;
         description
           "The resource representing the attribute.";
       }
       leaf value {
         type string;
         description
           "The value represented as a string since it could
            be of any type.";
       }
       reference
         "ITU Recommendation X.721: Information Technology
             - Open Systems Interconnection
             - Structure of management information:
               Definition of management information
          Module Attribute-ASN1Module";
     }

     /*
      * Add X.733 parameters to the alarm definitions, alarms,
      * and notification.
      */

     augment "/al:alarms/al:alarm-inventory/al:alarm-type" {
       description
         "Augment X.733 mapping information to the alarm inventory.";
       uses x733-alarm-definition-parameters;
     }

Vallin & Bjorklund      Expires October 13, 2019               [Page 63]
Internet-Draft              YANG Alarm Module                 April 2019

     /*
      * Add X.733 configurable mapping.
      */

     augment "/al:alarms/al:control" {
       description
         "Add X.733 mapping capabilities. ";
       list x733-mapping {
         if-feature "configure-x733-mapping";
         key "alarm-type-id alarm-type-qualifier-match";
         description
           "This list allows a management application to control the
            X.733 mapping for all alarm types in the system. Any entry
            in this list will allow the alarm manager to over-ride the
            default X.733 mapping in the system and the final mapping
            will be shown in the alarm inventory.";
         leaf alarm-type-id {
           type al:alarm-type-id;
           description
             "Map the alarm type with this alarm type identifier.";
         }
         leaf alarm-type-qualifier-match {
           type string;
           description
             "A W3C regular expression that is used when mapping an
              alarm type and alarm-type-qualifier to X.733 parameters.";
         }
         uses x733-alarm-definition-parameters;
       }
     }

     augment "/al:alarms/al:alarm-list/al:alarm" {
       description
         "Augment X.733 information to the alarm.";
       uses x733-alarm-parameters;
     }

     augment "/al:alarms/al:shelved-alarms/al:shelved-alarm" {
       description
         "Augment X.733 information to the alarm.";
       uses x733-alarm-parameters;
     }

     augment "/al:alarm-notification" {
       description
         "Augment X.733 information to the alarm notification.";
       uses x733-alarm-parameters;
     }

Vallin & Bjorklund      Expires October 13, 2019               [Page 64]
Internet-Draft              YANG Alarm Module                 April 2019

   }

   <CODE ENDS>

9.  IANA Considerations

   This document registers two URIs in the IETF XML registry [RFC3688].
   Following the format in RFC 3688, the following registrations are
   requested to be made.

       URI: urn:ietf:params:xml:ns:yang:ietf-alarms
       Registrant Contact: The IESG.
       XML: N/A, the requested URI is an XML namespace.

       URI: urn:ietf:params:xml:ns:yang:ietf-alarms-x733
       Registrant Contact: The IESG.
       XML: N/A, the requested URI is an XML namespace.

   This document registers two YANG modules in the YANG Module Names
   registry [RFC6020].

       name:        ietf-alarms
       namespace:   urn:ietf:params:xml:ns:yang:ietf-alarms
       prefix:      al
       reference:   RFC XXXX

       name:        ietf-alarms-x733
       namespace:   urn:ietf:params:xml:ns:yang:ietf-alarms-x733
       prefix:      x733
       reference:   RFC XXXX

10.  Security Considerations

   The YANG module specified in this document defines a schema for data
   that is designed to be accessed via network management protocols such
   as NETCONF [RFC6241] or RESTCONF [RFC8040].  The lowest NETCONF layer
   is the secure transport layer, and the mandatory-to-implement secure
   transport is Secure Shell (SSH) [RFC6242].  The lowest RESTCONF layer
   is HTTPS, and the mandatory-to-implement secure transport is TLS
   [RFC8446].

   The Network Configuration Access Control model (NACM) [RFC8341]
   provides the means to restrict access for particular NETCONF or
   RESTCONF users to a preconfigured subset of all available NETCONF or
   RESTCONF protocol operations and content.

Vallin & Bjorklund      Expires October 13, 2019               [Page 65]
Internet-Draft              YANG Alarm Module                 April 2019

   The list of alarms itself may be potentially sensitive from a
   security perspective, in that it potentially gives an attacker an
   authoritative picture of the (broken) state of the network.

   There are a number of data nodes defined in this YANG module that are
   writable/creatable/deletable (i.e., config true, which is the
   default).  These data nodes may be considered sensitive or vulnerable
   in some network environments.  Write operations (e.g., edit-config)
   to these data nodes without proper protection can have a negative
   effect on network operations.  These are the subtrees and data nodes
   and their sensitivity/vulnerability:

   /alarms/control/notify-status-changes:  This leaf controls whether an
      alarm should notify based on various state changes.  Unauthorized
      access to this leaf could have a negative impact on operational
      procedures relying on fine-grained alarm state change reporting

   /alarms/control/alarm-shelving/shelf:  This list controls the
      shelving (blocking) of alarms.  Unauthorized access to this list
      could jeopardize the alarm management procedures since these
      alarms will not be notified and not be part of the alarm list.

   /alarms/control/alarm-profile/alarm-severity-assignment-profile:
      This list controls the severity levels of an alarm.  Unauthorized
      access to this could for example downgrade the severity of an
      alarm and thereby have a negative impact on the alarm monitoring
      process.

   Some of the operations in this YANG module may be considered
   sensitive or vulnerable in some network environments.  It is thus
   important to control access to these operations.  These are the
   operations and their sensitivity/vulnerability:

   /alarms/alarm-list/purge-alarms:  This action deletes alarms from the
      alarm list.  Unauthorized use of this action could jeopardize the
      alarm management procedures since the deleted alarms may be vital
      for the alarm management application.

   /alarms/alarm-list/alarm/set-operator-state:  This action can be used
      by the operator to indicate the level of human intervention on an
      alarm.  Unauthorized use of this action could result in alarms
      being ignored by operators.

11.  Acknowledgements

   The authors wish to thank Viktor Leijon and Johan Nordlander for
   their valuable input on forming the alarm model.

Vallin & Bjorklund      Expires October 13, 2019               [Page 66]
Internet-Draft              YANG Alarm Module                 April 2019

   The authors also wish to thank Nick Hancock, Joey Boyd, Tom Petch and
   Balazs Lengyel for their extensive reviews and contributions to this
   document.

12.  References

12.1.  Normative References

   [M.3100]   International Telecommunications Union, "Generic Network
              Information Model", ITU-T Recommendation M.3100, 2005.

   [M.3160]   International Telecommunications Union, "Generic,
              protocol-neutral management information model",
              ITU-T Recommendation M.3100, 2008.

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <https://www.rfc-editor.org/info/rfc2119>.

   [RFC3688]  Mealling, M., "The IETF XML Registry", BCP 81, RFC 3688,
              DOI 10.17487/RFC3688, January 2004,
              <https://www.rfc-editor.org/info/rfc3688>.

   [RFC6020]  Bjorklund, M., Ed., "YANG - A Data Modeling Language for
              the Network Configuration Protocol (NETCONF)", RFC 6020,
              DOI 10.17487/RFC6020, October 2010,
              <https://www.rfc-editor.org/info/rfc6020>.

   [RFC6241]  Enns, R., Ed., Bjorklund, M., Ed., Schoenwaelder, J., Ed.,
              and A. Bierman, Ed., "Network Configuration Protocol
              (NETCONF)", RFC 6241, DOI 10.17487/RFC6241, June 2011,
              <https://www.rfc-editor.org/info/rfc6241>.

   [RFC6242]  Wasserman, M., "Using the NETCONF Protocol over Secure
              Shell (SSH)", RFC 6242, DOI 10.17487/RFC6242, June 2011,
              <https://www.rfc-editor.org/info/rfc6242>.

   [RFC6991]  Schoenwaelder, J., Ed., "Common YANG Data Types",
              RFC 6991, DOI 10.17487/RFC6991, July 2013,
              <https://www.rfc-editor.org/info/rfc6991>.

   [RFC7950]  Bjorklund, M., Ed., "The YANG 1.1 Data Modeling Language",
              RFC 7950, DOI 10.17487/RFC7950, August 2016,
              <https://www.rfc-editor.org/info/rfc7950>.

Vallin & Bjorklund      Expires October 13, 2019               [Page 67]
Internet-Draft              YANG Alarm Module                 April 2019

   [RFC8040]  Bierman, A., Bjorklund, M., and K. Watsen, "RESTCONF
              Protocol", RFC 8040, DOI 10.17487/RFC8040, January 2017,
              <https://www.rfc-editor.org/info/rfc8040>.

   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
              2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
              May 2017, <https://www.rfc-editor.org/info/rfc8174>.

   [RFC8341]  Bierman, A. and M. Bjorklund, "Network Configuration
              Access Control Model", STD 91, RFC 8341,
              DOI 10.17487/RFC8341, March 2018,
              <https://www.rfc-editor.org/info/rfc8341>.

   [RFC8348]  Bierman, A., Bjorklund, M., Dong, J., and D. Romascanu, "A
              YANG Data Model for Hardware Management", RFC 8348,
              DOI 10.17487/RFC8348, March 2018,
              <https://www.rfc-editor.org/info/rfc8348>.

   [RFC8446]  Rescorla, E., "The Transport Layer Security (TLS) Protocol
              Version 1.3", RFC 8446, DOI 10.17487/RFC8446, August 2018,
              <https://www.rfc-editor.org/info/rfc8446>.

   [X.721]    International Telecommunications Union, "Information
              Technology - Open Systems Interconnection - Structure of
              management information: Definition of management
              information", ITU-T Recommendation X.721, 1992.

   [X.733]    International Telecommunications Union, "Information
              Technology - Open Systems Interconnection - Systems
              Management: Alarm Reporting Function",
              ITU-T Recommendation X.733, 1992.

   [XSD-TYPES]
              Malhotra, A. and P. Biron, "XML Schema Part 2: Datatypes
              Second Edition", World Wide Web Consortium Recommendation
              REC-xmlschema-2-20041028, October 2004,
              <http://www.w3.org/TR/2004/REC-xmlschema-2-20041028>.

12.2.  Informative References

   [ALARMIRP]
              3GPP, "Telecommunication management; Fault Management;
              Part 2: Alarm Integration Reference Point (IRP):
              Information Service (IS)", 3GPP TS 32.111-2 3.4.0, March
              2005.

Vallin & Bjorklund      Expires October 13, 2019               [Page 68]
Internet-Draft              YANG Alarm Module                 April 2019

   [ALARMSEM]
              Wallin, S., Leijon, V., Nordlander, J., and N. Bystedt,
              "The semantics of alarm definitions: enabling systematic
              reasoning about alarms. International Journal of Network
              Management, Volume 22, Issue 3, John Wiley and Sons, Ltd,
              http://dx.doi.org/10.1002/nem.800", March 2012.

   [EEMUA]    EEMUA Publication No. 191 Engineering Equipment and
              Materials Users Association, London, 2 edition., "Alarm
              Systems: A Guide to Design, Management and Procurement.",
              2007.

   [G.7710]   ITU-T, "SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL
              SYSTEMS AND NETWORKS Data over Transport - Generic aspects
              - Transport network control aspects.  Common equipment
              management function requirements", 2012.

   [I-D.ietf-netmod-yang-instance-file-format]
              Lengyel, B. and B. Claise, "YANG Instance Data File
              Format", draft-ietf-netmod-yang-instance-file-format-02
              (work in progress), February 2019.

   [ISA182]   International Society of Automation,ISA, "ANSI/ISA-
              18.2-2009 Management of Alarm Systems for the Process
              Industries", 2009.

   [RFC3877]  Chisholm, S. and D. Romascanu, "Alarm Management
              Information Base (MIB)", RFC 3877, DOI 10.17487/RFC3877,
              September 2004, <https://www.rfc-editor.org/info/rfc3877>.

   [RFC8340]  Bjorklund, M. and L. Berger, Ed., "YANG Tree Diagrams",
              BCP 215, RFC 8340, DOI 10.17487/RFC8340, March 2018,
              <https://www.rfc-editor.org/info/rfc8340>.

   [X.736]    International Telecommunications Union, "Information
              Technology - Open Systems Interconnection - Systems
              Management: Security alarm reporting function",
              ITU-T Recommendation X.736, 1992.

Appendix A.  Vendor-specific Alarm Types Example

   This example shows how to define alarm types in a vendor-specific
   module.  In this case the vendor "xyz" has chosen to define top level
   identities according to X.733 event types.

Vallin & Bjorklund      Expires October 13, 2019               [Page 69]
Internet-Draft              YANG Alarm Module                 April 2019

   module example-xyz-alarms {
     namespace "urn:example:xyz-alarms";
     prefix xyz-al;

     import ietf-alarms {
       prefix al;
     }

     identity xyz-alarms {
       base al:alarm-type-id;
     }

     identity communications-alarm {
       base xyz-alarms;
     }
     identity quality-of-service-alarm {
       base xyz-alarms;
     }
     identity processing-error-alarm {
       base xyz-alarms;
     }
     identity equipment-alarm {
       base xyz-alarms;
     }
     identity environmental-alarm {
       base xyz-alarms;
     }

     // communications alarms
     identity link-alarm {
       base communications-alarm;
     }

     // QoS alarms
     identity high-jitter-alarm {
       base quality-of-service-alarm;
     }
   }

Appendix B.  Alarm Inventory Example

   This shows an alarm inventory, it shows one alarm type defined only
   with the identifier, and another dynamically configured.  In the
   latter case a digital input has been connected to a smoke-detector,
   therefore the "alarm-type-qualifier" is set to "smoke-detector" and
   the "alarm-type-id" to "environmental-alarm".

Vallin & Bjorklund      Expires October 13, 2019               [Page 70]
Internet-Draft              YANG Alarm Module                 April 2019

   <alarms xmlns="urn:ietf:params:xml:ns:yang:ietf-alarms"
           xmlns:xyz-al="urn:example:xyz-alarms"
           xmlns:dev="urn:example:device">
     <alarm-inventory>
       <alarm-type>
         <alarm-type-id>xyz-al:link-alarm</alarm-type-id>
         <alarm-type-qualifier/>
         <resource>
           /dev:interfaces/dev:interface
         </resource>
         <will-clear>true</will-clear>
         <description>
           Link failure, operational state down but admin state up
         </description>
       </alarm-type>
       <alarm-type>
         <alarm-type-id>xyz-al:environmental-alarm</alarm-type-id>
         <alarm-type-qualifier>smoke-alarm</alarm-type-qualifier>
         <will-clear>true</will-clear>
         <description>
           Connected smoke detector to digital input
         </description>
       </alarm-type>
     </alarm-inventory>
   </alarms>

Appendix C.  Alarm List Example

   In this example we show an alarm that has toggled [major, clear,
   major].  An operator has acknowledged the alarm.

   <alarms xmlns="urn:ietf:params:xml:ns:yang:ietf-alarms"
           xmlns:xyz-al="urn:example:xyz-alarms"
           xmlns:dev="urn:example:device">
     <alarm-list>
       <number-of-alarms>1</number-of-alarms>
       <last-changed>2018-04-08T08:39:50.00Z</last-changed>
       <alarm>
         <resource>
           /dev:interfaces/dev:interface[name='FastEthernet1/0']
         </resource>
         <alarm-type-id>xyz-al:link-alarm</alarm-type-id>
         <alarm-type-qualifier></alarm-type-qualifier>
         <time-created>2018-04-08T08:20:10.00Z</time-created>
         <is-cleared>false</is-cleared>
         <alt-resource>1.3.6.1.2.1.2.2.1.1.17</alt-resource>
         <last-raised>2018-04-08T08:39:40.00Z</last-raised>

Vallin & Bjorklund      Expires October 13, 2019               [Page 71]
Internet-Draft              YANG Alarm Module                 April 2019

         <last-changed>2018-04-08T08:39:50.00Z</last-changed>
         <perceived-severity>major</perceived-severity>
         <alarm-text>
           Link operationally down but administratively up
         </alarm-text>
         <status-change>
           <time>2018-04-08T08:39:40.00Z</time>
           <perceived-severity>major</perceived-severity>
           <alarm-text>
             Link operationally down but administratively up
           </alarm-text>
         </status-change>
         <status-change>
           <time>2018-04-08T08:30:00.00Z</time>
           <perceived-severity>cleared</perceived-severity>
           <alarm-text>
             Link operationally up and administratively up
           </alarm-text>
         </status-change>
         <status-change>
           <time>2018-04-08T08:20:10.00Z</time>
           <perceived-severity>major</perceived-severity>
           <alarm-text>
             Link operationally down but administratively up
           </alarm-text>
         </status-change>
         <operator-state-change>
           <time>2018-04-08T08:39:50.00Z</time>
           <state>ack</state>
           <operator>joe</operator>
           <text>Will investigate, ticket TR764999</text>
         </operator-state-change>
       </alarm>
     </alarm-list>
   </alarms>

Appendix D.  Alarm Shelving Example

   This example shows how to shelf alarms.  We shelf alarms related to
   the smoke-detectors since they are being installed and tested.  We
   also shelf all alarms from FastEthernet1/0.

Vallin & Bjorklund      Expires October 13, 2019               [Page 72]
Internet-Draft              YANG Alarm Module                 April 2019

   <alarms xmlns="urn:ietf:params:xml:ns:yang:ietf-alarms"
           xmlns:xyz-al="urn:example:xyz-alarms"
           xmlns:dev="urn:example:device">
     <control>
       <alarm-shelving>
         <shelf>
           <name>FE10</name>
           <resource>
             /dev:interfaces/dev:interface[name='FastEthernet1/0']
           </resource>
         </shelf>
         <shelf>
           <name>detectortest</name>
           <alarm-type>
             <alarm-type-id>
               xyz-al:environmental-alarm
             </alarm-type-id>
             <alarm-type-qualifier-match>
               smoke-alarm
             </alarm-type-qualifier-match>
           </alarm-type>
         </shelf>
       </alarm-shelving>
     </control>
   </alarms>

Appendix E.  X.733 Mapping Example

   This example shows how to map a dynamic alarm type (alarm-type-
   id=environmental-alarm, alarm-type-qualifier=smoke-alarm) to the
   corresponding X.733 "event-type" and "probable-cause" parameters.

   <alarms xmlns="urn:ietf:params:xml:ns:yang:ietf-alarms"
           xmlns:xyz-al="urn:example:xyz-alarms">
     <control>
       <x733-mapping
          xmlns="urn:ietf:params:xml:ns:yang:ietf-alarms-x733">
         <alarm-type-id>xyz-al:environmental-alarm</alarm-type-id>
         <alarm-type-qualifier-match>
           smoke-alarm
         </alarm-type-qualifier-match>
         <event-type>quality-of-service-alarm</event-type>
         <probable-cause>777</probable-cause>
       </x733-mapping>
     </control>
   </alarms>

Vallin & Bjorklund      Expires October 13, 2019               [Page 73]
Internet-Draft              YANG Alarm Module                 April 2019

Appendix F.  Relationship to other alarm standards

   This section briefly describes how this alarm module relates to other
   relevant standards.

F.1.  Alarm definition

   The table below summarizes relevant definitions of the term "alarm"
   in other alarm standards.

   +------------+---------------------------+--------------------------+
   | Standard   | Definition                | Comment                  |
   +------------+---------------------------+--------------------------+
   | X.733      | error: A deviation of a   | The X.733 alarm          |
   | [X.733]    | system from normal        | definition is focused on |
   |            | operation.  fault: The    | the notification as such |
   |            | physical or algorithmic   | and not the state. X.733 |
   |            | cause of a malfunction.   | defines an alarm as a    |
   |            | Faults manifest           | deviation from normal    |
   |            | themselves as errors.     | condition, but without   |
   |            | alarm: A notification, of | the requirement that it  |
   |            | the form defined by this  | needs corrective         |
   |            | function, of a specific   | actions.                 |
   |            | event. An alarm may or    |                          |
   |            | may not represent an      |                          |
   |            | error.                    |                          |
   |            |                           |                          |
   | G.7710     | Alarms are indications    | The G.7710 definition is |
   | [G.7710]   | that are automatically    | close to the original    |
   |            | generated by a device as  | X.733 definition.        |
   |            | a result of the           |                          |
   |            | declaration of a failure. |                          |
   |            |                           |                          |
   | Alarm MIB  | Alarm: Persistent         | RFC 3877 defines the     |
   | [RFC3877]  | indication of a fault.    | term alarm referring     |
   |            | Fault: Lasting error or   | back to "a deviation     |
   |            | warning condition.        | from normal operation".  |
   |            | Error: A deviation of a   | The Alarm YANG model     |
   |            | system from normal        | adds the requirement     |
   |            | operation.                | that it should require a |
   |            |                           | corrective action and    |
   |            |                           | should be undesired, not |
   |            |                           | only a deviation from    |
   |            |                           | normal.  The alarm MIB   |
   |            |                           | is state oriented in the |
   |            |                           | same way as the Alarm    |
   |            |                           | YANG, it focuses on the  |
   |            |                           | "lasting  condition",    |

Vallin & Bjorklund      Expires October 13, 2019               [Page 74]
Internet-Draft              YANG Alarm Module                 April 2019

   |            |                           | not the individual       |
   |            |                           | notifications.           |
   |            |                           |                          |
   | ISA        | Alarm: An audible and/or  | The ISA standard adds an |
   | [ISA182]   | visible means of          | important requirement to |
   |            | indicating to the         | the "deviation from      |
   |            | operator an equipment     | normal condition state": |
   |            | malfunction, process      | requiring a response.    |
   |            | deviation or abnormal     |                          |
   |            | condition requiring a     |                          |
   |            | response.                 |                          |
   |            |                           |                          |
   | EEMUA      | An alarm is an event to   | This is the foundation   |
   | [EEMUA]    | which an operator must    | for the definition of    |
   |            | knowingly react,respond,  | alarm in this document.  |
   |            | and acknowledge - not     | It focuses on the core   |
   |            | simply acknowledge and    | criteria that an action  |
   |            | ignore.                   | is really needed.        |
   |            |                           |                          |
   | 3GPP Alarm | 3GPP v15: An alarm        | The latest 3GPP Alarm    |
   | IRP        | signifies an undesired    | IRP version uses         |
   | [ALARMIRP] | condition of a resource   | literally the same alarm |
   |            | (e.g. device, link) for   | definition as this alarm |
   |            | which an operator action  | module. It is worth      |
   |            | is required. It           | noting that earlier      |
   |            | emphasizes a key          | versions used a          |
   |            | requirement that          | definition not requiring |
   |            | operators [...] should    | an operator action and   |
   |            | not be informed about an  | the more broad           |
   |            | undesired condition       | definition of deviation  |
   |            | unless it requires        | from normal condition.   |
   |            | operator action.  3GPP    | The earlier version also |
   |            | v12: alarm: abnormal      | defined an alarm as a    |
   |            | network entity condition, | special case of "event". |
   |            | which categorizes an      |                          |
   |            | event as a fault.  fault: |                          |
   |            | a deviation of a system   |                          |
   |            | from normal operation,    |                          |
   |            | which may result in the   |                          |
   |            | loss of operational       |                          |
   |            | capabilities [...]        |                          |
   +------------+---------------------------+--------------------------+

                 Table 1: Definition of alarm in standards

   The evolution of the definition of alarm moves from focused on events
   reporting a deviation from normal operation towards a definition to a
   undesired *state* which *requires an operator action*.

Vallin & Bjorklund      Expires October 13, 2019               [Page 75]
Internet-Draft              YANG Alarm Module                 April 2019

F.2.  Data model

   This section describes how this YANG alarm module relates to other
   standard data models.  Note well that we cover other data models for
   alarm interfaces.  Not other standards such as SDO specific alarms
   for example.

F.2.1.  X.733

   X.733 has acted as a base for several alarm data models over the
   year.  The YANG alarm module differs in the following ways:

      X.733 models the alarm list as a list of notifications.  The YANG
      alarm module defines the alarm list as the current alarm states
      for the resources, which is generated from the state change
      reporting notifications.

      In X.733 an alarm can have the severity level clear.  In the YANG
      alarm module "clear" is not a severity level, it is a separate
      state of the alarm.  An alarm can have the following states for
      example (major, cleared), (minor, not cleared)

      X.733 uses a flat globally defined enumerated "probable-cause" to
      identify alarm types.  This alarm module uses a hierarchical YANG
      identity, "alarm-type".  This enables delegation of alarm types
      within organizations.  It also lets management reason about
      abstract alarm types corresponding to base identities, see
      Section 3.2.

      The YANG alarm module has not included the majority of the X.733
      alarm attributes.  Rather these are defined in an augmenting
      module if "strict" X.733 compliance is needed.

F.2.2.  RFC 3877, the Alarm MIB

   The MIB in RFC 3877 takes a different approach, rather than defining
   a concrete data model for alarms, it defines a model to map existing
   SNMP managed objects and notifications into alarm states and alarm
   notifications.  This was necessary since MIBs were already defined
   with both managed objects and notifications indicating alarms, for
   example linkUp and linkDown notifications in combination with
   ifAdminState and ifOperState.  So RFC 3877 can not really be compared
   to the alarm YANG module in that sense.

   The Alarm MIB maps existing MIB definitions into alarms,
   alarmModelTable.  The upside of that is that a SNMP Manager can at
   runtime read the possible alarm types.  This corresponds to the
   alarmInventory in the alarm YANG module.

Vallin & Bjorklund      Expires October 13, 2019               [Page 76]
Internet-Draft              YANG Alarm Module                 April 2019

F.2.3.  3GPP Alarm IRP

   The 3GPP Alarm IRP is an evolution of X.733.  Main differences
   between the alarm YANG module and 3GPP are:

      3GPP keeps the majority of the X.733 attributes, the alarm YANG
      module does not.

      3GPP introduced overlapping and possibly conflicting keys for
      alarms, alarmId and (managed object, event type, probable cause,
      specific problem).  (See Annex C in [X.733] Example 3).  In the
      YANG alarm module the key for identifying an alarm instance is
      clearly defined by ("resource", "alarm-type-id", "alarm-type-
      qualifier").  See also Section 3.4 for more information.

      The alarm YANG module clearly separates the resource/
      instrumentation life cycle from the operator life cycle. 3GPP
      allows operators to set the alarm severity to clear, this is not
      allowed by this module, rather an operator closes an alarm which
      does not affect the severity.

F.2.4.  G.7710

   G.7710 is different than the previous referenced alarm standards.  It
   does not define a data model for alarm reporting.  It defines common
   equipment management function requirements including alarm
   instrumentation.  The scope is transport networks.

   The requirements in G.7710 corresponds to features in the alarm YANG
   module in the following way:

      Alarm Severity Assignment Profile (ASAP): the alarm profile
      "/alarms/alarm-profile/".

      Alarm Reporting Control (ARC): alarm shelving "/alarms/control/
      alarm-shelving/" and the ability to control alarm notifications
      "/alarms/control/notify-status-changes".  Alarm shelving
      corresponds to the use case of turning off alarm reporting for a
      specific resource, the NALM state in M.3100.

Appendix G.  Alarm Usability Requirements

   This section defines usability requirements for alarms.  Alarm
   usability is important for an alarm interface.  A data model will
   help in defining the format but if the actual alarms are of low value
   we have not gained the goal of alarm management.

Vallin & Bjorklund      Expires October 13, 2019               [Page 77]
Internet-Draft              YANG Alarm Module                 April 2019

   Common alarm problems and the cause of the problems are summarized in
   Table 2.  This summary is adopted to networking based on the ISA
   [ISA182] and EEMUA [EEMUA] standards.

Vallin & Bjorklund      Expires October 13, 2019               [Page 78]
Internet-Draft              YANG Alarm Module                 April 2019

   +------------------+--------------------------------+---------------+
   | Problem          | Cause                          | How this      |
   |                  |                                | module        |
   |                  |                                | address the   |
   |                  |                                | cause         |
   +------------------+--------------------------------+---------------+
   | Alarms are       | "Nuisance" alarms (chattering  | Strict        |
   | generated but    | alarms and fleeting alarms),   | definition of |
   | they are ignored | faulty hardware, redundant     | alarms        |
   | by the operator. | alarms, cascading alarms,      | requiring     |
   |                  | incorrect alarm settings,      | corrective    |
   |                  | alarms have not been           | response.     |
   |                  | rationalized, the alarms       | Alarm         |
   |                  | represent log information      | requirements  |
   |                  | rather than true alarms.       | in Table 3.   |
   |                  |                                |               |
   | When alarms      | Insufficient alarm response    | The alarm     |
   | occur, operators | procedures and not well        | inventory     |
   | do not know how  | defined alarm types.           | lists all     |
   | to respond.      |                                | alarm types   |
   |                  |                                | and           |
   |                  |                                | corrective    |
   |                  |                                | actions.      |
   |                  |                                | Alarm         |
   |                  |                                | requirements  |
   |                  |                                | in Table 3.   |
   |                  |                                |               |
   | The alarm        | Nuisance alarms, stale alarms, | The alarm     |
   | display is full  | alarms from equipment not in   | definition    |
   | of alarms, even  | service.                       | and alarm     |
   | when there is    |                                | shelving.     |
   | nothing wrong.   |                                |               |
   |                  |                                |               |
   | During a         | Incorrect prioritization of    | State-based   |
   | failure,         | alarms. Not using advanced     | alarm model,  |
   | operators are    | alarm techniques (e.g. state-  | alarm rate    |
   | flooded with so  | based alarming).               | requirements  |
   | many alarms that |                                | in Table 4    |
   | they do not know |                                | and Table 5   |
   | which ones are   |                                |               |
   | the most         |                                |               |
   | important.       |                                |               |
   +------------------+--------------------------------+---------------+

                    Table 2: Alarm Problems and Causes

   Based upon the above problems EEMUA gives the following definition of
   a good alarm:

Vallin & Bjorklund      Expires October 13, 2019               [Page 79]
Internet-Draft              YANG Alarm Module                 April 2019

   +----------------+--------------------------------------------------+
   | Characteristic | Explanation                                      |
   +----------------+--------------------------------------------------+
   | Relevant       | Not spurious or of low operational value.        |
   |                |                                                  |
   | Unique         | Not duplicating another alarm.                   |
   |                |                                                  |
   | Timely         | Not long before any response is needed or too    |
   |                | late to do anything.                             |
   |                |                                                  |
   | Prioritized    | Indicating the importance that the operator      |
   |                | deals with the problem.                          |
   |                |                                                  |
   | Understandable | Having a message which is clear and easy to      |
   |                | understand.                                      |
   |                |                                                  |
   | Diagnostic     | Identifying the problem that has occurred.       |
   |                |                                                  |
   | Advisory       | Indicative of the action to be taken.            |
   |                |                                                  |
   | Focusing       | Drawing attention to the most important issues.  |
   +----------------+--------------------------------------------------+

                    Table 3: Definition of a Good Alarm

   Vendors SHOULD rationalize all alarms according to above.  Another
   crucial requirement is acceptable alarm notification rates.  Vendors
   SHOULD make sure that they do not exceed the recommendations from
   EEMUA below:

   +-----------------------------------+-------------------------------+
   | Long Term Alarm Rate in Steady    | Acceptability                 |
   | Operation                         |                               |
   +-----------------------------------+-------------------------------+
   | More than one per minute          | Very likely to be             |
   |                                   | unacceptable.                 |
   |                                   |                               |
   | One per 2 minutes                 | Likely to be over-demanding.  |
   |                                   |                               |
   | One per 5 minutes                 | Manageable.                   |
   |                                   |                               |
   | Less than one per 10 minutes      | Very likely to be acceptable. |
   +-----------------------------------+-------------------------------+

               Table 4: Acceptable Alarm Rates, Steady State

Vallin & Bjorklund      Expires October 13, 2019               [Page 80]
Internet-Draft              YANG Alarm Module                 April 2019

   +----------------------------+--------------------------------------+
   | Number of alarms displayed | Acceptability                        |
   | in 10 minutes following a  |                                      |
   | major network problem      |                                      |
   +----------------------------+--------------------------------------+
   | More than 100              | Definitely excessive and very likely |
   |                            | to lead to the operator to abandon   |
   |                            | the use of the alarm system.         |
   |                            |                                      |
   | 20-100                     | Hard to cope with.                   |
   |                            |                                      |
   | Under 10                   | Should be manageable - but may be    |
   |                            | difficult if several of the alarms   |
   |                            | require a complex operator response. |
   +----------------------------+--------------------------------------+

                  Table 5: Acceptable Alarm Rates, Burst

   The numbers in Table 4 and Table 5 are the sum of all alarms for a
   network being managed from one alarm console.  So every individual
   system or NMS contributes to these numbers.

   Vendors SHOULD make sure that the following rules are used in
   designing the alarm interface:

   1.  Rationalize the alarms in the system to ensure that every alarm
       is necessary, has a purpose, and follows the cardinal rule - that
       it requires an operator response.  Adheres to the rules of
       Table 3

   2.  Audit the quality of the alarms.  Talk with the operators about
       how well the alarm information support them.  Do they know what
       to do in the event of an alarm?  Are they able to quickly
       diagnose the problem and determine the corrective action?  Does
       the alarm text adhere to the requirements in Table 3?

   3.  Analyze and benchmark the performance of the system and compare
       it to the recommended metrics in Table 4 and Table 5.  Start by
       identifying nuisance alarms, standing alarms at normal state and
       startup.

Authors' Addresses

   Stefan Vallin
   Stefan Vallin AB

   Email: stefan@wallan.se

Vallin & Bjorklund      Expires October 13, 2019               [Page 81]
Internet-Draft              YANG Alarm Module                 April 2019

   Martin Bjorklund
   Cisco

   Email: mbj@tail-f.com

Vallin & Bjorklund      Expires October 13, 2019               [Page 82]