[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

PROPOSED STANDARD
Network Working Group                                       C. Krupczak
Request for Comments: 2287                    Empire Technologies, Inc.
Category: Standards Track                                    J. Saperia
                                                       BGS Systems Inc.
                                                          February 1998


      Definitions of System-Level Managed Objects for Applications

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (1998).  All Rights Reserved.

Table of Contents

   1 Abstract ..............................................    2
   2 The SNMPv2 Network Management Framework ...............    2
   2.1 Object Definitions ..................................    2
   3 Overview ..............................................    3
   4 Architecture for Application Management ...............    3
   5 The Structure of the MIB ..............................    4
   5.1 System Application Installed Group ..................    5
   5.2 System Application Run Group ........................    5
   5.2.1 sysApplRunTable and sysApplPastRunTable ...........    5
   5.2.2 sysApplElmtRunTable and  sysApplElmtPastRunTable
        ....................................................    6
   5.3 System Application Map Group ........................    7
   6 Definitions ...........................................    7
   7 Implementation Issues .................................   40
   7.1 Implementation with Polling Agents ..................   40
   7.2 sysApplElmtPastRunTable Entry Collisions ............   40
   8 Security Considerations ...............................   41
   9 Acknowledgements ......................................   42
   10 Author's Address .....................................   42
   11 References ...........................................   42
   12 Full Copyright Statement .............................   44







Krupczak & Saperia          Standards Track                     [Page 1]


RFC 2287                  MIB for Applications             February 1998


1.  Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it describes a basic set of managed objects for fault,
   configuration and performance management of applications from a
   systems perspective.  More specifically, the managed objects are
   restricted to information that can be determined from the system
   itself and which does not require special instrumentation within the
   applications to make the information available.

   This memo does not specify a standard for the Internet community.

2.  The SNMPv2 Network Management Framework

   The SNMPv2 Network Management Framework consists of the following
   major components:

   o    RFC 1902 Structure of Management Information for Version
        2 of the Simple Network Management Protocol (SNMPv2) [2]

   o    RFC 1903 Textual Conventions for Version 2 of the Simple
        Network Management Protocol (SNMPv2) [3]

   o    RFC 1904 Conformance Statements for Version 2 of the
        Simple Network Management Protocol (SNMPv2) [4]

   o    RFC 1905 Protocol Operations for Version 2 of the Simple
        Network Management Protocol (SNMPv2) [5]

   o    RFC 1906 Transport Mappings for Version 2 of the Simple
        Network Management Protocol (SNMPv2) [6]

   o    RFC 1907 Management Information Base for Version 2 of the
        Simple Network Management Protocol (SNMPv2) [7]

   o    RFC 1908 Coexistence between Version 1 and Version 2 of
        the Internet-standard Network Management Framework [8]

   The Framework permits new objects to be defined for the purpose of
   experimentation and evaluation.

2.1.  Object Definitions

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB. Objects in the MIB are
   defined using the subset of Abstract Syntax Notation One (ASN.1) [1],
   defined in the Structure of Management Information (SMI)  (See RFC



Krupczak & Saperia          Standards Track                     [Page 2]


RFC 2287                  MIB for Applications             February 1998


   1902 [2]). In particular, each object type is named by an OBJECT
   IDENTIFIER, an administratively assigned name. The object type
   together with an object instance serves to uniquely identify a
   specific instantiation of the object. For human convenience, we often
   use a textual string, termed the object descriptor, to refer to the
   object type.

3.  Overview

   The primary purpose of computing technologies is the execution of
   application software. These applications, typically specialized
   collections of executables, files, and interprocess communications,
   exist to solve business, scientific or other "problems". The
   configuration, fault detection, performance monitoring and control of
   application software across its life on a host computer is of great
   economic importance. For the purposes of our work, we define
   applications as one or more units of executable code and other
   resources, installed on a single host system that a manager may think
   of as a single object for management purposes.

   The information described by the objects in the System Application
   MIB support configuration, fault, and performance management; they
   represent some of the basic attributes of application software from a
   systems (non-application specific) perspective.  The information
   allows for the description of applications as collections of
   executables and files installed and executing on a host computer.

   This memo is concerned primarily with, and defines a model for,
   application information resident on a host computer which can be
   determined from the system itself, and not from the individual
   applications.  This system-level view of applications is designed to
   provide information about software applications installed and running
   on the host system without requiring modifications and code additions
   to the applications themselves.  This approach was taken to insure
   ease and speed of implementation, while allowing room for future
   growth.

4.  Architecture for Application Management

   In the area of application management it is fully acknowledged and
   even expected that additional MIB modules will be defined over time
   to provide an even greater level of detail regarding applications.
   This MIB module presents the most general case:  a set of management
   objects for providing generic information about applications and
   whose object values can be determined from the computer system itself
   without requiring instrumentation within the application.





Krupczak & Saperia          Standards Track                     [Page 3]


RFC 2287                  MIB for Applications             February 1998


   A finer-grained level of detail is planned for the future "appl MIB"
   which will be a common set of management objects relating to generic
   applications, but which require some type of instrumentation in the
   application in order to be determined.  Since the applmib MIB module
   will provide a finer level of detail, any connection to the sysAppl
   MIB should be made by having references from the more detailed appl
   MIB back to the more generic sysAppl MIB.  Likewise, as application-
   specific MIB modules such as the WWW MIB, etc., are developed over
   time, these more specific MIBs should reference back to the more
   generic MIBs.

   While this MIB module does not attempt to provide every detailed
   piece of information for managing applications, it does provide a
   basic systems-level view of the applications and their components on
   a single host system.

5.  The Structure of the MIB

   The System Application MIB structure models application packages as a
   whole, and also models the individual elements (files and
   executables) which collectively form an application.  The MIB is
   structured to model information regarding installed application
   packages and the elements which make up each application package. The
   MIB also models activity information on applications (and in turn,
   their components) that are running or have previously run on the host
   system.  In modeling applications and their elements, this MIB module
   provides the necessary link for associating executing processes with
   the applications of which they are a part.

   The objects are arranged into the following groups:

       -  System Application Installed Group
              - sysApplInstallPkgTable
              - sysApplInstallElmtTable

       -  System Application Run Group
              - sysApplRunTable
              - sysApplPastRunTable
              - sysApplElmtRunTable
              - sysApplElmtPastRunTable
              - (scalars for restricting table sizes)

       -  System Application Map Group
              - sysApplMapTable







Krupczak & Saperia          Standards Track                     [Page 4]


RFC 2287                  MIB for Applications             February 1998


   As can be seen by the arrangement above, for each category, the MIB
   first treats an application package as a whole, and then breaks down
   the package to provide information about each of the elements
   (executable and non-executable files) of the package.

5.1.  System Application Installed Group

   The System Application Installed group consists of two tables.
   Through these two tables, administrators will be able to determine
   which applications have been installed on a system and what their
   constituent components are.  The first table, the
   sysApplInstallPkgTable, lists the application packages installed on a
   particular host. The second, the sysApplInstallElmtTable, provides
   information regarding the executables and non-executable files, or
   elements, which collectively compose an application.

   NOTE: This MIB is intended to work with applications that have been
   installed on a particular host, where "installed" means that the
   existence of the application and the association between an
   application and its component files can be discovered without
   requiring additional instrumentation of the application itself.  This
   may require that certain conventions be used, such as using a central
   software installation mechanism or registry, when installing
   application packages.  For example, many UNIX systems utilize a
   "pkgadd" utility to track installed application packages, while many
   PC systems utilize a global registry.

5.2.  System Application Run Group

   This group models activity information for applications that have
   been invoked and are either currently running, or have previously
   run, on the host system.  Likewise, the individual elements of an
   invoked application are also modeled to show currently running
   processes, and processes that have run in the past.  This information
   is modeled using two pairs of tables: a pair of tables for currently
   running applications and past run applications, and a pair of tables
   for the currently running elements and the past run elements.  Seven
   scalars are also defined to control the size of the past run tables.

5.2.1.  sysApplRunTable and sysApplPastRunTable

   The sysApplRunTable and the sysApplPastRunTable make up the first
   pair of tables.  The sysApplRunTable contains the application
   instances which are currently running on the host.  Each time an
   application is invoked, a new entry is created in the sysApplRunTable
   to provide information about that particular invocation of the
   application.  An entry will remain in this table until the




Krupczak & Saperia          Standards Track                     [Page 5]


RFC 2287                  MIB for Applications             February 1998


   application instance terminates, at which time the entry will be
   deleted from the sysApplRunTable and placed in the
   sysApplPastRunTable.

   The sysApplPastRunTable maintains a history of instances of
   applications which have previously executed on the host.  Entries to
   this table are made when an invoked application from the
   sysApplRunTable terminates; the table entry which represents the
   application instance is removed from the SysApplRunTable and a
   corresponding entry is added to the sysApplPastRunTable.

   Because the sysApplPastRunTable will continuously grow as
   applications are executed and terminate, two scalars are defined to
   control the aging-out of table entries. The value of
   sysApplPastRunMaxRows specifies the maximum number of entries the
   table may contain, while the sysApplPastRunTblTimeLimit specifies the
   maximum age of the table entries.  Oldest entries are removed first.

   It is important to note that the sysApplRunTable and
   sysApplPastRunTable contain entries for each INVOCATION of an
   application. A single application package might be invoked multiple
   times; each invocation is properly recorded by a separate entry in
   the sysApplRunTable.

   In order to implement this group, the agent must be able to recognize
   that an application has been invoked, and be able to determine when
   that invocation terminates.  This poses a complex problem since a
   single application invocation may involve numerous processes, some of
   which may be required to remain running throughout the duration of
   the application, others which might come and go.  The
   sysApplInstallElmtRole columnar object in the sysApplInstallElmtTable
   is meant to assist in this task by indicating which element is the
   application's primary executable, which elements must be running in
   order for the application to be running, which elements are dependent
   on required elements, etc.  See the description of
   sysApplInstallElmtRole for more details.

5.2.2.  sysApplElmtRunTable and sysApplElmtPastRunTable

   While the sysApplRunTable and sysApplPastRunTable focus on
   applications as a whole, the sysApplElmtRunTable and
   sysApplElmtPastRunTable provide information regarding an
   application's executable elements, (processes), which are either
   currently executing or have executed in the past.

   The sysApplElmtRunTable contains an entry for every process currently
   running on the host.  An entry is created in this table for each
   process at the time it is started, and will remain in the table until



Krupczak & Saperia          Standards Track                     [Page 6]


RFC 2287                  MIB for Applications             February 1998


   the process terminates.  Note that in order to provide complete
   information on the load on the system, this table lists EVERY running
   process, not just those processes that are running as part of an
   identified application.  However, when processes terminate, only
   information from entries corresponding to elements of an identified
   application are moved to the sysApplElmtPastRunTable.

   The sysApplElmtPastRunTable maintains a history of processes which
   have previously executed on the host as part of an application. When
   a process from the sysApplElmtRunTable terminates, the entry's
   information is moved to this sysApplElmtPastRunTable provided that
   the process was part of an identified application.  If the process
   cannot be associated with any 'parent' application, then it is simply
   removed from the sysApplElmtRunTable.  This allows for processes like
   'ps' or 'grep' to show up in the sysApplElmtRunTable, (where they are
   consuming resources and are thus "interesting"), but not in the
   sysApplElmtPastRunTable.

   Because the sysApplElmtPastRunTable will continuously grow as
   processes are executed and terminate, two scalars are defined to
   control the aging-out of table entries.  The value of
   sysApplElmtPastRunMaxRows specifies the maximum number of entries the
   table may contain, while the sysApplElmtPastRunTblTimeLimit specifies
   the maximum age of the table entries.  Oldest entries are removed
   first.

5.3.  System Application Map Group

   The System Application Map group contains a single table, the
   sysApplMapTable, whose sole purpose is to provide a backwards mapping
   for determining the invoked application, installed element, and
   installed application package given a known process identification
   number.

6.  Definitions

   SYSAPPL-MIB DEFINITIONS ::= BEGIN

   IMPORTS
       MODULE-IDENTITY, OBJECT-TYPE,
       Unsigned32, TimeTicks, Counter32, Gauge32
           FROM SNMPv2-SMI
       DateAndTime, TEXTUAL-CONVENTION
           FROM SNMPv2-TC
       MODULE-COMPLIANCE, OBJECT-GROUP
           FROM SNMPv2-CONF
       mib-2 FROM SNMPv2-SMI;




Krupczak & Saperia          Standards Track                     [Page 7]


RFC 2287                  MIB for Applications             February 1998


   -- System Application MIB

   sysApplMIB MODULE-IDENTITY
       LAST-UPDATED "9710200000Z"
       ORGANIZATION "IETF Applications MIB Working Group"
       CONTACT-INFO
             "Cheryl Krupczak (Editor, WG Advisor)
              Postal: Empire Technologies, Inc.
              541 Tenth Street NW
              Suite 169
              Atlanta, GA 30318
              USA
              Phone: (770) 384-0184
              Email: cheryl@empiretech.com

              Jon Saperia (WG Chair)
              Postal:  BGS Systems, Inc.
              One First Avenue
              Waltham, MA 02254-9111
              USA
              Phone: (617) 891-0000
              Email: saperia@networks.bgs.com"
       DESCRIPTION
           "The MIB module defines management objects that model
           applications as collections of executables and files
           installed and executing on a host system.  The MIB
           presents a system-level view of applications; i.e.,
           objects in this MIB are limited to those attributes
           that can typically be obtained from the system itself
           without adding special instrumentation to the applications."
       ::= { mib-2 54  }


   sysApplOBJ               OBJECT IDENTIFIER ::= { sysApplMIB 1 }
   sysApplInstalled         OBJECT IDENTIFIER ::= { sysApplOBJ 1 }
   sysApplRun               OBJECT IDENTIFIER ::= { sysApplOBJ 2 }
   sysApplMap               OBJECT IDENTIFIER ::= { sysApplOBJ 3 }
   sysApplNotifications     OBJECT IDENTIFIER ::= { sysApplMIB 2 }
   sysApplConformance       OBJECT IDENTIFIER ::= { sysApplMIB 3 }

   -- Textual Conventions

   RunState ::= TEXTUAL-CONVENTION
       STATUS      current
       DESCRIPTION
           "This TC describes the current execution state of
           a running application or process.  The possible
           values are:



Krupczak & Saperia          Standards Track                     [Page 8]


RFC 2287                  MIB for Applications             February 1998


             running(1),
             runnable(2),  - waiting for a resource (CPU, etc.)
             waiting(3),   - waiting for an event
             exiting(4),
             other(5)      - other invalid state"
       SYNTAX      INTEGER {
                   running (1),
                   runnable (2), -- waiting for resource (CPU, etc.)
                   waiting (3),  -- waiting for event
                   exiting (4),
                   other (5)     -- other invalid state
                   }

 LongUtf8String ::= TEXTUAL-CONVENTION
         DISPLAY-HINT "1024a"
         STATUS  current
         DESCRIPTION
                 "To facilitate internationalization, this TC
                  represents information taken from the ISO/IEC IS
                  10646-1 character set, encoded as an octet string
                  using the UTF-8 character encoding scheme described
                  in RFC 2044 [10].  For strings in 7-bit US-ASCII,
                  there is no impact since the UTF-8 representation
                  is identical to the US-ASCII encoding."
         SYNTAX  OCTET STRING (SIZE (0..1024))

 Utf8String ::= TEXTUAL-CONVENTION
         DISPLAY-HINT "255a"
         STATUS  current
         DESCRIPTION
                 "To facilitate internationalization, this TC
                  represents information taken from the ISO/IEC IS
                  10646-1 character set, encoded as an octet string
                  using the UTF-8 character encoding scheme described
                  in RFC 2044 [10].  For strings in 7-bit US-ASCII,
                  there is no impact since the UTF-8 representation
                  is identical to the US-ASCII encoding."
         SYNTAX  OCTET STRING (SIZE (0..255))



   -- sysApplInstalled Group
   -- This group provides information about application packages
   -- that have been installed on the host computer.  The group
   -- contains two tables.  The first, the sysApplInstallPkgTable,
   -- describes the application packages, the second, the
   -- sysApplInstallElmtTable, describes the constituent elements
   -- (files and executables) which compose an application package.



Krupczak & Saperia          Standards Track                     [Page 9]


RFC 2287                  MIB for Applications             February 1998


   --
   -- In order to appear in this group, an application and its
   -- component files must be discoverable by the system itself,
   -- possibly through some type of software installation mechanism
   -- or registry.

   -- sysApplInstallPkgTable
   -- The system installed application packages table provides
   -- information on the software packages installed on a system.
   -- These packages may consist of many different files including
   -- executable and non-executable files.

   sysApplInstallPkgTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplInstallPkgEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The table listing the software application packages
           installed on a host computer. In order to appear in
           this table, it may be necessary for the application
           to be installed using some type of software
           installation mechanism or global registry so that its
           existence can be detected by the agent implementation."

       ::= { sysApplInstalled 1 }

   sysApplInstallPkgEntry OBJECT-TYPE
       SYNTAX      SysApplInstallPkgEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The logical row describing an installed application
           package."
       INDEX    { sysApplInstallPkgIndex }
       ::= { sysApplInstallPkgTable 1 }

   SysApplInstallPkgEntry ::= SEQUENCE {
       sysApplInstallPkgIndex               Unsigned32,
       sysApplInstallPkgManufacturer        Utf8String,
       sysApplInstallPkgProductName         Utf8String,
       sysApplInstallPkgVersion             Utf8String,
       sysApplInstallPkgSerialNumber        Utf8String,
       sysApplInstallPkgDate                DateAndTime,
       sysApplInstallPkgLocation            LongUtf8String
   }

   sysApplInstallPkgIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (1..'ffffffff'h)



Krupczak & Saperia          Standards Track                    [Page 10]


RFC 2287                  MIB for Applications             February 1998


       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "An integer used only for indexing purposes.
           Generally monotonically increasing from 1 as new
           applications are installed.

           The value for each installed application must
           remain constant at least from one re-initialization of
           the network management entity which implements this
           MIB module to the next re-initialization.

           The specific value is meaningful only within a given SNMP
           entity. A sysApplInstallPkgIndex value must not be re-used
           until the next agent entity restart in the event the
           installed application entry is deleted."
       ::= { sysApplInstallPkgEntry 1 }

   sysApplInstallPkgManufacturer OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The Manufacturer of the software application package."
       ::= { sysApplInstallPkgEntry 2 }

   sysApplInstallPkgProductName OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The name assigned to the software application package
           by the Manufacturer."
       ::= { sysApplInstallPkgEntry 3 }

   sysApplInstallPkgVersion OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The version number assigned to the application package
           by the manufacturer of the software."
       ::= { sysApplInstallPkgEntry 4 }

   sysApplInstallPkgSerialNumber OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current



Krupczak & Saperia          Standards Track                    [Page 11]


RFC 2287                  MIB for Applications             February 1998


       DESCRIPTION
           "The serial number of the software assigned by the
           manufacturer."
       ::= { sysApplInstallPkgEntry 5 }

   sysApplInstallPkgDate OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The date and time this software application was installed
           on the host."
       ::= { sysApplInstallPkgEntry 6 }

   sysApplInstallPkgLocation OBJECT-TYPE
       SYNTAX      LongUtf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The complete path name where the application package
           is installed.  For example, the value would be
           '/opt/MyapplDir' if the application package was installed
           in the /opt/MyapplDir directory."
       ::= { sysApplInstallPkgEntry 7 }


   -- sysApplInstallElmtTable
   -- The table describing the individual application package
   -- elements (files and executables) installed on the host computer.

   sysApplInstallElmtTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplInstallElmtEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This table details the individual application package
           elements (files and executables) which comprise the
           applications defined in the sysApplInstallPkg Table.
           Each entry in this table has an index to the
           sysApplInstallPkg table to identify the application
           package of which it is a part. As a result, there may
           be many entries in this table for each instance in the
           sysApplInstallPkg Table.

           Table entries are indexed by sysApplInstallPkgIndex,
           sysApplInstallElmtIndex to facilitate retrieval of
           all elements associated with a particular installed
           application package."



Krupczak & Saperia          Standards Track                    [Page 12]


RFC 2287                  MIB for Applications             February 1998


       ::= { sysApplInstalled 2 }

   sysApplInstallElmtEntry OBJECT-TYPE
       SYNTAX      SysApplInstallElmtEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The logical row describing an element of an installed
           application.  The element may be an executable or
           non-executable file."
       INDEX    {sysApplInstallPkgIndex, sysApplInstallElmtIndex}
       ::= { sysApplInstallElmtTable 1 }

   SysApplInstallElmtEntry ::= SEQUENCE {
       sysApplInstallElmtIndex                 Unsigned32,
       sysApplInstallElmtName                  Utf8String,
       sysApplInstallElmtType                  INTEGER,
       sysApplInstallElmtDate                  DateAndTime,
       sysApplInstallElmtPath                  LongUtf8String,
       sysApplInstallElmtSizeHigh              Unsigned32,
       sysApplInstallElmtSizeLow               Unsigned32,
       sysApplInstallElmtRole                  BITS,
       sysApplInstallElmtModifyDate            DateAndTime,
       sysApplInstallElmtCurSizeHigh           Unsigned32,
       sysApplInstallElmtCurSizeLow            Unsigned32

   }

   sysApplInstallElmtIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (1..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "An arbitrary integer used for indexing.  The value
           of this index is unique among all rows in this table
           that exist or have existed since the last agent restart."
       ::= { sysApplInstallElmtEntry 1 }


   sysApplInstallElmtName OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The name of this element which is contained in the
           application."
       ::= { sysApplInstallElmtEntry 2 }




Krupczak & Saperia          Standards Track                    [Page 13]


RFC 2287                  MIB for Applications             February 1998


   sysApplInstallElmtType OBJECT-TYPE
       SYNTAX      INTEGER {
                   unknown(1),
                   nonexecutable(2),
                   operatingSystem(3),  -- executable
                   deviceDriver(4),     -- executable
                   application(5)       -- executable
                   }
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The type of element that is part of the installed
           application."
       ::= { sysApplInstallElmtEntry 3 }

   sysApplInstallElmtDate OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The date and time that this component was installed on
           the system."
       ::= { sysApplInstallElmtEntry 4 }

   sysApplInstallElmtPath OBJECT-TYPE
       SYNTAX      LongUtf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The full directory path where this element is installed.
           For example, the value would be '/opt/EMPuma/bin' for an
           element installed in the directory '/opt/EMPuma/bin'.
           Most application packages include information about the
           elements contained in the package. In addition, elements
           are typically installed in sub-directories under the
           package installation directory.  In cases where the
           element path names are not included in the package
           information itself, the path can usually be determined
           by a simple search of the sub-directories.  If the
           element is not installed in that location and there is
           no other information available to the agent implementation,
           then the path is unknown and null is returned."
       ::= { sysApplInstallElmtEntry 5}

   sysApplInstallElmtSizeHigh OBJECT-TYPE
       SYNTAX      Unsigned32
       MAX-ACCESS  read-only
       STATUS      current



Krupczak & Saperia          Standards Track                    [Page 14]


RFC 2287                  MIB for Applications             February 1998


       DESCRIPTION
           "The installed file size in 2^32 byte blocks. This is
           the size of the file on disk immediately after installation.

           For example, for a file with a total size of 4,294,967,296
           bytes, this variable would have a value of 1; for a file
           with a total size of 4,294,967,295 bytes this variable
           would be 0."
       ::= { sysApplInstallElmtEntry 6 }

   sysApplInstallElmtSizeLow OBJECT-TYPE
       SYNTAX      Unsigned32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The installed file size modulo 2^32 bytes.  This is
           the size of the file on disk immediately after installation.

           For example, for a file with a total size of 4,294,967,296
           bytes this variable would have a value of 0; for a file with
           a total size of 4,294,967,295 bytes this variable would be
           4,294,967,295."
       ::= { sysApplInstallElmtEntry 7 }

   sysApplInstallElmtRole  OBJECT-TYPE
       SYNTAX      BITS {
                   executable(0),
                      -- An application may have one or
                      -- more executable elements.  The rest of the
                      -- bits have no meaning if the element is not
                      -- executable.
                   exclusive(1),
                      -- Only one copy of an exclusive element may be
                      -- running per invocation of the running
                      -- application.
                   primary(2),
                      -- The primary executable.  An application can
                      -- have one, and only one element that is designated
                      -- as the primary executable.  The execution of
                      -- this element constitutes an invocation of
                      -- the application.  This is used by the agent
                      -- implementation to determine the initiation of
                      -- an application.  The primary executable must
                      -- remain running long enough for the agent
                      -- implementation to detect its presence.
                   required(3),
                      -- An application may have zero or more required
                      -- elements. All required elements must be running



Krupczak & Saperia          Standards Track                    [Page 15]


RFC 2287                  MIB for Applications             February 1998


                      -- in order for the application to be judged to be
                      -- running and healthy.
                   dependent(4),
                      -- An application may have zero or more
                      -- dependent elements. Dependent elements may
                      -- not be running unless required elements are.
                   unknown(5)
                      -- Default value for the case when an operator
                      -- has not yet assigned one of the other values.
                      -- When set, bits 1, 2, 3, and 4 have no meaning.
                   }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "An operator assigned value used in the determination of
           application status. This value is used by the agent to
           determine both the mapping of started processes to the
           initiation of an application, as well as to allow for a
           determination of application health. The default value,
           unknown(5), is used when an operator has not yet assigned
           one of the other values.  If unknown(5) is set, bits
           1 - 4 have no meaning.  The possible values are:

                   executable(0),
                       An application may have one or
                       more executable elements.  The rest of the
                       bits have no meaning if the element is not
                       executable.
                   exclusive(1),
                       Only one copy of an exclusive element may be
                       running per invocation of the running
                       application.
                   primary(2),
                       The primary executable.  An application can
                       have one, and only one element that is designated
                       as the primary executable.  The execution of
                       this element constitutes an invocation of
                       the application.  This is used by the agent
                       implementation to determine the initiation of
                       an application.  The primary executable must
                       remain running long enough for the agent
                       implementation to detect its presence.
                   required(3),
                       An application may have zero or more required
                       elements. All required elements must be running
                       in order for the application to be judged to be
                       running and healthy.
                   dependent(4),



Krupczak & Saperia          Standards Track                    [Page 16]


RFC 2287                  MIB for Applications             February 1998


                       An application may have zero or more
                       dependent elements. Dependent elements may
                       not be running unless required elements are.
                   unknown(5)
                       Default value for the case when an operator
                       has not yet assigned one of the other values.
                       When set, bits 1, 2, 3, and 4 have no meaning.

            sysApplInstallElmtRole is used by the agent implementation
            in determining the initiation of an application, the
            current state of a running application (see
            sysApplRunCurrentState), when an application invocation is
            no longer running, and the exit status of a terminated
            application invocation (see sysApplPastRunExitState)."

       DEFVAL { { unknown } }
       ::= { sysApplInstallElmtEntry 8 }

   sysApplInstallElmtModifyDate OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The date and time that this element was last modified.
           Modification of the sysApplInstallElmtRole columnar
           object does NOT constitute a modification of the element
           itself and should not affect the value of this object."
       ::= { sysApplInstallElmtEntry 9 }

   sysApplInstallElmtCurSizeHigh OBJECT-TYPE
       SYNTAX      Unsigned32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The current file size in 2^32 byte blocks.
           For example, for a file with a total size of 4,294,967,296
           bytes, this variable would have a value of 1; for a file
           with a total size of 4,294,967,295 bytes this variable
           would be 0."
       ::= { sysApplInstallElmtEntry 10 }

   sysApplInstallElmtCurSizeLow OBJECT-TYPE
       SYNTAX      Unsigned32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The current file size modulo 2^32 bytes.
           For example, for a file with a total size of 4,294,967,296



Krupczak & Saperia          Standards Track                    [Page 17]


RFC 2287                  MIB for Applications             February 1998


           bytes this variable would have a value of 0; for a file with
           a total size of 4,294,967,295 bytes this variable would be
           4,294,967,295."
       ::= { sysApplInstallElmtEntry 11 }



   -- sysApplRun Group
   -- This group models activity information for applications
   -- that have been invoked and are either currently running,
   -- or have previously run on the host system.  Likewise,
   -- the individual elements of an invoked application are
   -- also modeled to show currently running processes, and
   -- processes that have run in the past.

   -- sysApplRunTable
   -- The sysApplRunTable contains the application instances
   -- which are currently running on the host.  Since a single
   -- application might be invoked multiple times, an entry is
   -- added to this table for each INVOCATION of an application.
   -- The table is indexed by sysApplInstallPkgIndex, sysApplRunIndex
   -- to enable managers to easily locate all invocations of
   -- a particular application package.

   sysApplRunTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The table describes the applications which are executing
           on the host.  Each time an application is invoked,
           an entry is created in this table. When an application ends,
           the entry is removed from this table and a corresponding
                   entry is created in the SysApplPastRunTable.

           A new entry is created in this table whenever the agent
           implementation detects a new running process that is an
           installed application element whose sysApplInstallElmtRole
           designates it as being the application's primary executable
           (sysApplInstallElmtRole = primary(2) ).

           The table is indexed by sysApplInstallPkgIndex,
           sysApplRunIndex to enable managers to easily locate all
           invocations of a particular application package."
       ::= { sysApplRun 1 }

   sysApplRunEntry OBJECT-TYPE
       SYNTAX      SysApplRunEntry



Krupczak & Saperia          Standards Track                    [Page 18]


RFC 2287                  MIB for Applications             February 1998


       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The logical row describing an application which is
           currently running on this host."
       INDEX    { sysApplInstallPkgIndex, sysApplRunIndex }
       ::= { sysApplRunTable   1 }

   SysApplRunEntry ::= SEQUENCE {
       sysApplRunIndex                         Unsigned32,
       sysApplRunStarted                       DateAndTime,
       sysApplRunCurrentState                  RunState
   }

   sysApplRunIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (1..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table. An arbitrary
           integer used only for indexing purposes. Generally
           monotonically increasing from 1 as new applications are
           started on the host, it uniquely identifies application
           invocations.

           The numbering for this index increases by 1 for each
           INVOCATION of an application, regardless of which
           installed application package this entry represents a
           running instance of.

           An example of the indexing for a couple of entries is
           shown below.

                         :
                    sysApplRunStarted.17.14
                    sysApplRunStarted.17.63
                    sysApplRunStarted.18.13
                         :

           In this example, the agent has observed 12 application
           invocations when the application represented by entry 18
           in the sysApplInstallPkgTable is invoked.  The next
           invocation detected by the agent is an invocation of
           installed application package 17.  Some time later,
           installed application 17 is invoked a second time.

           NOTE: this index is not intended to reflect a real-time
           (wall clock time) ordering of application invocations;



Krupczak & Saperia          Standards Track                    [Page 19]


RFC 2287                  MIB for Applications             February 1998


           it is merely intended to uniquely identify running
           instances of applications.  Although the
           sysApplInstallPkgIndex is included in the INDEX clause
           for this table, it serves only to ease searching of
           this table by installed application and does not
           contribute to uniquely identifying table entries."
       ::= { sysApplRunEntry 1 }

   sysApplRunStarted OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The date and time that the application was started."
       ::= { sysApplRunEntry 2 }

   sysApplRunCurrentState OBJECT-TYPE
       SYNTAX      RunState
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The current state of the running application instance.
           The possible values are running(1), runnable(2) but waiting
           for a resource such as CPU, waiting(3) for an event,
           exiting(4), or other(5). This value is based on an evaluation
           of the running elements of this application instance (see
           sysApplElmRunState) and their Roles as defined by
           sysApplInstallElmtRole.  An agent implementation may
           detect that an application instance is in the process of
           exiting if one or more of its REQUIRED elements are no
           longer running.  Most agent implementations will wait until
           a second internal poll has been completed to give the
           system time to start REQUIRED elements before marking the
           application instance as exiting."
       ::= { sysApplRunEntry 3 }


   -- sysApplPastRunTable
   -- The sysApplPastRunTable provides a history of applications
   -- previously run on the host computer. Entries are removed from
   -- the sysApplRunTable and corresponding entries are added to this
   -- table when an application becomes inactive. Entries remain in
   -- this table until they are aged out when either the table size
   -- reaches a maximum as determined by the sysApplPastRunMaxRows,
   -- or when an entry has aged to exceed a time limit as set be
   -- sysApplPastRunTblTimeLimit.
   --
   -- When aging out entries, the oldest entry, as determined by



Krupczak & Saperia          Standards Track                    [Page 20]


RFC 2287                  MIB for Applications             February 1998


   -- the value of sysApplPastRunTimeEnded, will be removed first.

   sysApplPastRunTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplPastRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A history of the applications that have previously run
           on the host computer.  An entry's information is moved to
           this table from the sysApplRunTable when the invoked
           application represented by the entry ceases to be running.

           An agent implementation can determine that an application
           invocation is no longer running by evaluating the running
           elements of the application instance and their Roles as
           defined by sysApplInstallElmtRole.  Obviously, if there
           are no running elements for the application instance,
           then the application invocation is no longer running.
           If any one of the REQUIRED elements is not running,
           the application instance may be in the process of exiting.
           Most agent implementations will wait until a second internal
           poll has been completed to give the system time to either
           restart partial failures or to give all elements time to
           exit.  If, after the second poll, there are REQUIRED
           elements that are not running, then the application
           instance may be considered by the agent implementation
           to no longer be running.

           Entries remain in the sysApplPastRunTable until they
           are aged out when either the table size reaches a maximum
           as determined by the sysApplPastRunMaxRows, or when an entry
           has aged to exceed a time limit as set by
           sysApplPastRunTblTimeLimit.

           Entries in this table are indexed by sysApplInstallPkgIndex,
           sysApplPastRunIndex to facilitate retrieval of all past
           run invocations of a particular installed application."
       ::= { sysApplRun 2 }

   sysApplPastRunEntry OBJECT-TYPE
       SYNTAX      SysApplPastRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The logical row describing an invocation of an application
           which was previously run and has terminated.  The entry
           is basically copied from the sysApplRunTable when the
           application instance terminates.  Hence, the entry's



Krupczak & Saperia          Standards Track                    [Page 21]


RFC 2287                  MIB for Applications             February 1998


           value for sysApplPastRunIndex is the same as its value was
           for sysApplRunIndex."
       INDEX    { sysApplInstallPkgIndex, sysApplPastRunIndex }
       ::= { sysApplPastRunTable   1 }

   SysApplPastRunEntry ::= SEQUENCE {
       sysApplPastRunIndex                     Unsigned32,
       sysApplPastRunStarted                   DateAndTime,
       sysApplPastRunExitState                 INTEGER,
       sysApplPastRunTimeEnded                 DateAndTime
   }

   sysApplPastRunIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (1..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table. An integer
           matching the value of the removed sysApplRunIndex
           corresponding to this row."
       ::= { sysApplPastRunEntry 1 }

   sysApplPastRunStarted OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The date and time that the application was started."
       ::= { sysApplPastRunEntry 2 }

   sysApplPastRunExitState OBJECT-TYPE
       SYNTAX      INTEGER {
                   complete (1), -- normal exit at sysApplRunTimeEnded
                   failed (2),   -- abnormal exit
                   other (3)
                   }
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
         "The state of the application instance when it terminated.
          This value is based on an evaluation of the running elements
          of an application and their Roles as defined by
          sysApplInstallElmtRole.  An application instance is said to
          have exited in a COMPLETE state and its entry is removed
          from the sysApplRunTable and added to the sysApplPastRunTable
          when the agent detects that ALL elements of an application
          invocation are no longer running.  Most agent implementations
          will wait until a second internal poll has been completed to



Krupczak & Saperia          Standards Track                    [Page 22]


RFC 2287                  MIB for Applications             February 1998


          give the system time to either restart partial failures or
          to give all elements time to exit.  A failed state occurs if,
          after the second poll, any elements continue to run but
          one or more of the REQUIRED elements are no longer running.
          All other combinations MUST be defined as OTHER."
       ::= { sysApplPastRunEntry 3 }

   sysApplPastRunTimeEnded OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The DateAndTime the application instance was determined
           to be no longer running."
       ::= { sysApplPastRunEntry 4 }

   -- sysApplElmtRunTable
   -- The sysApplElmtRunTable contains an entry for each process that
   -- is currently running on the host.  An entry is created in
   -- this table for each process at the time it is started, and will
   -- remain in the table until the process terminates.
   --
   -- The table is indexed by sysApplElmtRunInstallPkg,
   -- sysApplElmtRunInvocID, and sysApplElmtRunIndex to make it easy
   -- to locate all running elements of a particular invoked application
   -- which has been installed on the system.


   sysApplElmtRunTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplElmtRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The table describes the processes which are
           currently executing on the host system. Each entry
           represents a running process and is associated with
           the invoked application of which that process is a part, if
           possible.  This table contains an entry for every process
           currently running on the system, regardless of whether its
           'parent' application can be determined.  So, for example,
           processes like 'ps' and 'grep' will have entries though they
           are not associated with an installed application package.

           Because a running application may involve
           more than one executable, it is possible to have
           multiple entries in this table for each application.
           Entries are removed from this table when the process
           terminates.



Krupczak & Saperia          Standards Track                    [Page 23]


RFC 2287                  MIB for Applications             February 1998


           The table is indexed by sysApplElmtRunInstallPkg,
           sysApplElmtRunInvocID, and sysApplElmtRunIndex to
           facilitate the retrieval of all running elements of a
           particular invoked application which has been installed on
           the system."
       ::= { sysApplRun 3 }

   sysApplElmtRunEntry OBJECT-TYPE
       SYNTAX      SysApplElmtRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The logical row describing a process currently
           running on this host.  When possible, the entry is
           associated with the invoked application of which it
           is a part."
       INDEX    { sysApplElmtRunInstallPkg, sysApplElmtRunInvocID,
                  sysApplElmtRunIndex }
       ::= { sysApplElmtRunTable   1 }

   SysApplElmtRunEntry ::= SEQUENCE {
       sysApplElmtRunInstallPkg        Unsigned32,
       sysApplElmtRunInvocID           Unsigned32,
       sysApplElmtRunIndex             Unsigned32,
       sysApplElmtRunInstallID         Unsigned32,
       sysApplElmtRunTimeStarted       DateAndTime,
       sysApplElmtRunState             RunState,
       sysApplElmtRunName              LongUtf8String,
       sysApplElmtRunParameters        Utf8String,
       sysApplElmtRunCPU               TimeTicks,
       sysApplElmtRunMemory            Gauge32,
       sysApplElmtRunNumFiles          Gauge32,
       sysApplElmtRunUser              Utf8String
   }

   sysApplElmtRunInstallPkg OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table, this value
           identifies the installed software package for
           the application of which this process is a part.
           Provided that the process's 'parent' application can be
           determined, the value of this object is the same
           value as the sysApplInstallPkgIndex for the
           entry in the sysApplInstallPkgTable that corresponds
           to the installed application of which this process



Krupczak & Saperia          Standards Track                    [Page 24]


RFC 2287                  MIB for Applications             February 1998


           is a part.

           If, however, the 'parent' application cannot be
           determined, (for example the process is not part
           of a particular installed application), the value
           for this object is then '0', signifying that this
           process cannot be related back to an application,
           and in turn, an installed software package."
       ::= { sysApplElmtRunEntry 1 }

   sysApplElmtRunInvocID OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table, this value
           identifies the invocation of an application of which
           this process is a part.  Provided that the 'parent'
           application can be determined, the value of this object
           is the same value as the sysApplRunIndex for the
           corresponding application invocation in the
           sysApplRunTable.

           If, however, the 'parent' application cannot be
           determined, the value for this object is then '0',
           signifying that this process cannot be related back
           to an invocation of an application in the
           sysApplRunTable."
       ::= { sysApplElmtRunEntry 2 }

   sysApplElmtRunIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table.  A unique value
           for each process running on the host.  Wherever
           possible, this should be the system's native, unique
           identification number."
       ::= { sysApplElmtRunEntry 3 }


   sysApplElmtRunInstallID OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The index into the sysApplInstallElmtTable. The



Krupczak & Saperia          Standards Track                    [Page 25]


RFC 2287                  MIB for Applications             February 1998


           value of this object is the same value as the
           sysApplInstallElmtIndex for the application element
           of which this entry represents a running instance.
           If this process cannot be associated with an installed
           executable, the value should be '0'."
       ::= { sysApplElmtRunEntry 4 }

   sysApplElmtRunTimeStarted OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The time the process was started."
       ::= { sysApplElmtRunEntry 5 }

   sysApplElmtRunState OBJECT-TYPE
       SYNTAX      RunState
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The current state of the running process. The
           possible values are running(1), runnable(2) but waiting
           for a resource such as CPU, waiting(3) for an event,
           exiting(4), or other(5)."
       ::= { sysApplElmtRunEntry 6 }

   sysApplElmtRunName OBJECT-TYPE
       SYNTAX      LongUtf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The full path and filename of the process.
           For example, '/opt/MYYpkg/bin/myyproc' would
           be returned for process 'myyproc' whose execution
           path is '/opt/MYYpkg/bin/myyproc'."
       ::= { sysApplElmtRunEntry 7 }

   sysApplElmtRunParameters OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The starting parameters for the process."
   ::= { sysApplElmtRunEntry 8 }

   sysApplElmtRunCPU OBJECT-TYPE
       SYNTAX      TimeTicks
       MAX-ACCESS  read-only



Krupczak & Saperia          Standards Track                    [Page 26]


RFC 2287                  MIB for Applications             February 1998


       STATUS      current
       DESCRIPTION
            "The number of centi-seconds of the total system's
            CPU resources consumed by this process.  Note that
            on a multi-processor system, this value may
            have been incremented by more than one centi-second
            in one centi-second of real (wall clock) time."
       ::= { sysApplElmtRunEntry 9 }

   sysApplElmtRunMemory OBJECT-TYPE
       SYNTAX      Gauge32
       UNITS       "Kbytes"
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The total amount of real system memory measured in
           Kbytes currently allocated to this process."

       ::= { sysApplElmtRunEntry 10 }

   sysApplElmtRunNumFiles OBJECT-TYPE
       SYNTAX      Gauge32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The number of regular files currently open by the
           process.  Transport connections (sockets)
           should NOT be included in the calculation of
           this value, nor should operating system specific
           special file types."
       ::= { sysApplElmtRunEntry 11 }

   sysApplElmtRunUser OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The process owner's login name (e.g. root)."
       ::= { sysApplElmtRunEntry 12 }

   -- sysApplElmtPastRunTable
   -- The sysApplElmtPastRunTable maintains a history of
   -- processes which have previously executed on
   -- the host as part of an application. Upon termination
   -- of a process, the entry representing the process is removed from
   -- the sysApplElmtRunTable and a corresponding entry is created in
   -- this table provided that the process was part of an
   -- identifiable application.  If the process could not be associated



Krupczak & Saperia          Standards Track                    [Page 27]


RFC 2287                  MIB for Applications             February 1998


   -- with an invoked application, no corresponding entry is created.
   -- Hence, whereas the sysApplElmtRunTable contains an entry for
   -- every process currently executing on the system, the
   -- sysApplElmtPastRunTable only contains entries for processes
   -- that previously executed as part of an invoked application.
   --
   -- Entries remain in this table until they are aged out when
   -- either the number of entries in the table reaches a
   -- maximum as determined by sysApplElmtPastRunMaxRows, or
   -- when an entry has aged to exceed a time limit as set by
   -- sysApplElmtPastRunTblTimeLimit.  When aging out entries,
   -- the oldest entry, as determined by the value of
   -- sysApplElmtPastRunTimeEnded, will be removed first.
   --
   -- The table is indexed by sysApplInstallPkgIndex (from the
   -- sysApplInstallPkgTable), sysApplElmtPastRunInvocID, and
   -- sysApplElmtPastRunIndex to make it easy to locate all
   -- previously executed processes of a particular invoked application
   -- that has been installed on the system.


   sysApplElmtPastRunTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplElmtPastRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The table describes the processes which have previously
           executed on the host system as part of an application.
           Each entry represents a process which has previously
           executed and is associated with the invoked application
           of which it was a part.  Because an invoked application
           may involve more than one executable, it is possible
           to have multiple entries in this table for
           each application invocation. Entries are added
           to this table when the corresponding process in the
           sysApplElmtRun Table terminates.

           Entries remain in this table until they are aged out when
           either the number of entries in the table reaches a
           maximum as determined by sysApplElmtPastRunMaxRows, or
           when an entry has aged to exceed a time limit as set by
           sysApplElmtPastRunTblTimeLimit.  When aging out entries,
           the oldest entry, as determined by the value of
           sysApplElmtPastRunTimeEnded, will be removed first.

           The table is indexed by sysApplInstallPkgIndex (from the
           sysApplInstallPkgTable), sysApplElmtPastRunInvocID,
           and sysApplElmtPastRunIndex to make it easy to locate all



Krupczak & Saperia          Standards Track                    [Page 28]


RFC 2287                  MIB for Applications             February 1998


           previously executed processes of a particular invoked
           application that has been installed on the system."
       ::= { sysApplRun 4 }

   sysApplElmtPastRunEntry OBJECT-TYPE
       SYNTAX      SysApplElmtPastRunEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The logical row describing a process which was
           previously executed on this host as part of an
           installed application.  The entry is basically copied
           from the sysApplElmtRunTable when the process
           terminates.  Hence, the entry's value for
           sysApplElmtPastRunIndex is the same as its value
           was for sysApplElmtRunIndex.  Note carefully: only those
           processes which could be associated with an
           identified application are included in this table."
       INDEX    { sysApplInstallPkgIndex, sysApplElmtPastRunInvocID,
                  sysApplElmtPastRunIndex }
       ::= { sysApplElmtPastRunTable   1 }

   SysApplElmtPastRunEntry ::= SEQUENCE {
       sysApplElmtPastRunInvocID           Unsigned32,
       sysApplElmtPastRunIndex             Unsigned32,
       sysApplElmtPastRunInstallID         Unsigned32,
       sysApplElmtPastRunTimeStarted       DateAndTime,
       sysApplElmtPastRunTimeEnded         DateAndTime,
       sysApplElmtPastRunName              LongUtf8String,
       sysApplElmtPastRunParameters        Utf8String,
       sysApplElmtPastRunCPU               TimeTicks,
       sysApplElmtPastRunMemory            Unsigned32,
       sysApplElmtPastRunNumFiles          Unsigned32,
       sysApplElmtPastRunUser              Utf8String
   }

   sysApplElmtPastRunInvocID OBJECT-TYPE
       SYNTAX      Unsigned32 (1..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table, this value
           identifies the invocation of an application of which
           the process represented by this entry was a part.
           The value of this object is the same value as the
           sysApplRunIndex for the corresponding application
           invocation in the sysApplRunTable.  If the invoked
           application as a whole has terminated, it will be the



Krupczak & Saperia          Standards Track                    [Page 29]


RFC 2287                  MIB for Applications             February 1998


           same as the sysApplPastRunIndex."
       ::= { sysApplElmtPastRunEntry 1 }

   sysApplElmtPastRunIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Part of the index for this table. An integer
           assigned by the agent equal to the corresponding
           sysApplElmtRunIndex which was removed from the
           sysApplElmtRunTable and moved to this table
           when the element terminated.

           Note: entries in this table are indexed by
           sysApplElmtPastRunInvocID, sysApplElmtPastRunIndex.
           The possibility exists, though unlikely, of a
           collision occurring by a new entry which was run
           by the same invoked application (InvocID), and
           was assigned the same process identification number
           (ElmtRunIndex) as an element which was previously
           run by the same invoked application.

           Should this situation occur, the new entry replaces
           the old entry.

           See Section: 'Implementation Issues -
           sysApplElmtPastRunTable Entry Collisions' for the
           conditions that would have to occur in order for a
           collision to occur."
       ::= { sysApplElmtPastRunEntry 2 }


   sysApplElmtPastRunInstallID OBJECT-TYPE
       SYNTAX      Unsigned32 (1..'ffffffff'h)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The index into the installed element table. The
           value of this object is the same value as the
           sysApplInstallElmtIndex for the application element
           of which this entry represents a previously executed
           process."
       ::= { sysApplElmtPastRunEntry 3 }

   sysApplElmtPastRunTimeStarted OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only



Krupczak & Saperia          Standards Track                    [Page 30]


RFC 2287                  MIB for Applications             February 1998


       STATUS      current
       DESCRIPTION
           "The time the process was started."
       ::= { sysApplElmtPastRunEntry 4 }

   sysApplElmtPastRunTimeEnded OBJECT-TYPE
       SYNTAX      DateAndTime
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The time the process ended."
       ::= { sysApplElmtPastRunEntry 5 }

   sysApplElmtPastRunName OBJECT-TYPE
       SYNTAX      LongUtf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The full path and filename of the process.
           For example, '/opt/MYYpkg/bin/myyproc' would
           be returned for process 'myyproc' whose execution
           path was '/opt/MYYpkg/bin/myyproc'."
       ::= { sysApplElmtPastRunEntry 6 }

   sysApplElmtPastRunParameters OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The starting parameters for the process."
       ::= { sysApplElmtPastRunEntry 7 }

   sysApplElmtPastRunCPU OBJECT-TYPE
       SYNTAX      TimeTicks
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
            "The last known number of centi-seconds of the total
            system's CPU resources consumed by this process.
            Note that on a multi-processor system, this value may
            increment by more than one centi-second in one
            centi-second of real (wall clock) time."
       ::= { sysApplElmtPastRunEntry 8 }

   sysApplElmtPastRunMemory OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       UNITS       "Kbytes"
       MAX-ACCESS  read-only



Krupczak & Saperia          Standards Track                    [Page 31]


RFC 2287                  MIB for Applications             February 1998


       STATUS      current
       DESCRIPTION
           "The last known total amount of real system memory
           measured in Kbytes allocated to this process before it
           terminated."
       ::= { sysApplElmtPastRunEntry 9 }

   sysApplElmtPastRunNumFiles OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The last known number of files open by the
           process before it terminated.  Transport
           connections (sockets) should NOT be included in
           the calculation of this value."
       ::= { sysApplElmtPastRunEntry 10 }

   sysApplElmtPastRunUser OBJECT-TYPE
       SYNTAX      Utf8String
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The process owner's login name (e.g. root)."
       ::= { sysApplElmtPastRunEntry 11 }


   -- Additional Scalar objects to control table sizes

   sysApplPastRunMaxRows OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The maximum number of entries allowed in the
           sysApplPastRunTable.  Once the number of rows in
           the sysApplPastRunTable reaches this value, the
           management subsystem will remove the oldest entry
           in the table to make room for the new entry to be added.
           Entries will be removed on the basis of oldest
           sysApplPastRunTimeEnded value first.

           This object may be used to control the amount of
           system resources that can used for sysApplPastRunTable
           entries. A conforming implementation should attempt
           to support the default value, however, a lesser value
           may be necessary due to implementation-dependent issues
           and resource availability."



Krupczak & Saperia          Standards Track                    [Page 32]


RFC 2287                  MIB for Applications             February 1998


       DEFVAL      { 500 }
       ::= { sysApplRun 5 }

   sysApplPastRunTableRemItems OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "A counter of the number of entries removed from
           the sysApplPastRunTable because of table size limitations
           as set in sysApplPastRunMaxRows.  This counter is the
           number of entries the management subsystem has had to
           remove in order to make room for new entries (so as not
           to exceed the limit set by sysApplPastRunMaxRows) since
           the last initialization of the management subsystem."
       ::= { sysApplRun 6 }

   sysApplPastRunTblTimeLimit OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       UNITS       "seconds"
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The maximum time in seconds which an entry in the
            sysApplPastRunTable may exist before it is removed.
            Any entry that is older than this value will be
            removed (aged out) from the table.

            Note that an entry may be aged out prior to reaching
            this time limit if it is the oldest entry in the
            table and must be removed to make space for a new
            entry so as to not exceed sysApplPastRunMaxRows."
       DEFVAL      { 7200 }
       ::= { sysApplRun 7 }

   sysApplElemPastRunMaxRows OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The maximum number of entries allowed in the
           sysApplElmtPastRunTable.  Once the number of rows in
           the sysApplElmtPastRunTable reaches this value,
           the management subsystem will remove the oldest entry
           to make room for the new entry to be added.  Entries
           will be removed on the basis of oldest
           sysApplElmtPastRunTimeEnded value first.




Krupczak & Saperia          Standards Track                    [Page 33]


RFC 2287                  MIB for Applications             February 1998


           This object may be used to control the amount of
           system resources that can used for sysApplElemPastRunTable
           entries. A conforming implementation should attempt
           to support the default value, however, a lesser value
           may be necessary due to implementation-dependent issues
           and resource availability."
       DEFVAL      { 500 }
       ::= { sysApplRun 8 }

   sysApplElemPastRunTableRemItems OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "A counter of the number of entries removed from the
           sysApplElemPastRunTable because of table size limitations
           as set in sysApplElemPastRunMaxRows.  This counter is the
           number of entries the management subsystem has had to
           remove in order to make room for new entries (so as not
           to exceed the limit set by sysApplElemPastRunMaxRows) since
           the last initialization of the management subsystem."
       ::= { sysApplRun 9 }

   sysApplElemPastRunTblTimeLimit OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       UNITS       "seconds"
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The maximum time in seconds which an entry in the
            sysApplElemPastRunTable may exist before it is removed.
            Any entry that is older than this value will be
            removed (aged out) from the table.

            Note that an entry may be aged out prior to reaching
            this time limit if it is the oldest entry in the
            table and must be removed to make space for a new
            entry so as to not exceed sysApplElemPastRunMaxRows."
       DEFVAL      { 7200 }
       ::= { sysApplRun 10 }

   sysApplAgentPollInterval  OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       UNITS       "seconds"
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The minimum interval in seconds that the management



Krupczak & Saperia          Standards Track                    [Page 34]


RFC 2287                  MIB for Applications             February 1998


           subsystem implementing this MIB will poll the status
           of the managed resources. Because of the non-trivial
           effort involved in polling the managed resources,
           and because the method for obtaining the status of
           the managed resources is implementation-dependent,
           a conformant implementation may chose a lower bound
           greater than 0.

           A value of 0 indicates that there is no delay
           in the passing of information from the managed
           resources to the agent."
       DEFVAL      { 60 }
       ::= { sysApplRun 11 }


   -- sysApplMap Group
   -- This group contains a table, the sysApplMapTable,
   -- whose sole purpose is to provide a 'backwards'
   -- mapping so that, given a known sysApplElmtRunIndex
   -- (process identification number), the corresponding invoked
   -- application (sysApplRunIndex), installed element
   -- (sysApplInstallElmtIndex), and installed application
   -- package (sysApplInstallPkgIndex) can be quickly determined.
   --
   -- The table will contain one entry for each process
   -- currently running on the system.
   --
   -- A backwards mapping is extremely useful since the tables
   -- in this MIB module are typically indexed with the
   -- installed application package (sysApplInstallPkgIndex)
   -- as the primary key, and on down as required by the
   -- specific table, with the process ID number (sysApplElmtRunIndex)
   -- being the least significant key.
   --
   -- It is expected that management applications will use
   -- this mapping table by doing a 'GetNext' operation with
   -- the known process ID number (sysApplElmtRunIndex) as the partial
   -- instance identifier.  Assuming that there is an entry for
   -- the process, the result should return a single columnar value,
   -- the sysApplMapInstallPkgIndex, with the sysApplElmtRunIndex,
   -- sysApplRunIndex, and sysApplInstallElmtIndex contained in the
   -- instance identifier for the returned MIB object value.
   --
   -- NOTE: if the process can not be associated back to an
   -- invoked application installed on the system, then the
   -- value returned for the columnar value sysApplMapInstallPkgIndex
   -- will be '0' and the instance portion of the object-identifier
   -- will be the process ID number (sysApplElmtRunIndex) followed



Krupczak & Saperia          Standards Track                    [Page 35]


RFC 2287                  MIB for Applications             February 1998


   -- by 0.0.

   sysApplMapTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysApplMapEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The sole purpose of this table is to provide a
           'backwards' mapping so that, given a known
           sysApplElmtRunIndex (process identification number),
           the corresponding invoked application (sysApplRunIndex),
           installed element (sysApplInstallElmtIndex), and
           installed application package (sysApplInstallPkgIndex)
           can be quickly determined.

           This table will contain one entry for each process
           that is currently executing on the system.

           It is expected that management applications will use
           this mapping table by doing a 'GetNext' operation with
           the known process ID number (sysApplElmtRunIndex) as the
           partial instance identifier.  Assuming that there is an
           entry for the process, the result should return a single
           columnar value, the sysApplMapInstallPkgIndex, with the
           sysApplElmtRunIndex, sysApplRunIndex, and
           sysApplInstallElmtIndex contained in the instance identifier
           for the returned MIB object value.

           NOTE: if the process can not be associated back to an
           invoked application installed on the system, then the
           value returned for the columnar value
           sysApplMapInstallPkgIndex will be '0' and the instance
           portion of the object-identifier will be the process ID
           number (sysApplElmtRunIndex) followed by 0.0."
       ::= { sysApplMap 1 }

   sysApplMapEntry OBJECT-TYPE
       SYNTAX      SysApplMapEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A logical row representing a process currently running
            on the system.  This entry provides the index mapping from
            process identifier, back to the invoked application,
            installed element, and finally, the installed application
            package.  The entry includes only one accessible columnar
            object, the sysApplMapInstallPkgIndex, but the
            invoked application and installed element can be



Krupczak & Saperia          Standards Track                    [Page 36]


RFC 2287                  MIB for Applications             February 1998


            determined from the instance identifier since they form
            part of the index clause."
       INDEX  { sysApplElmtRunIndex, sysApplElmtRunInvocID,
                sysApplMapInstallElmtIndex }
       ::= { sysApplMapTable 1 }

   SysApplMapEntry ::= SEQUENCE {
       sysApplMapInstallElmtIndex    Unsigned32,
       sysApplMapInstallPkgIndex     Unsigned32
   }

   sysApplMapInstallElmtIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The index into the sysApplInstallElmtTable. The
           value of this object is the same value as the
           sysApplInstallElmtIndex for the application element
           of which this entry represents a running instance.
           If this process cannot be associated to an installed
           executable, the value should be '0'."
       ::= { sysApplMapEntry 1 }

   sysApplMapInstallPkgIndex OBJECT-TYPE
       SYNTAX      Unsigned32 (0..'ffffffff'h)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "The value of this object identifies the installed
           software package for the application of which this
           process is a part.  Provided that the process's 'parent'
           application can be determined, the value of this object
           is the same value as the sysApplInstallPkgIndex for the
           entry in the sysApplInstallPkgTable that corresponds
           to the installed application of which this process
           is a part.

           If, however, the 'parent' application cannot be
           determined, (for example the process is not part
           of a particular installed application), the value
           for this object is then '0', signifying that this
           process cannot be related back to an application,
           and in turn, an installed software package."
       ::= { sysApplMapEntry 2 }


   -- Conformance Macros



Krupczak & Saperia          Standards Track                    [Page 37]


RFC 2287                  MIB for Applications             February 1998


   sysApplMIBCompliances  OBJECT IDENTIFIER ::= { sysApplConformance 1 }
   sysApplMIBGroups       OBJECT IDENTIFIER ::= { sysApplConformance 2 }

   sysApplMIBCompliance MODULE-COMPLIANCE
       STATUS  current
       DESCRIPTION
           "Describes the requirements for conformance to
           the System Application MIB"
       MODULE  -- this module
           MANDATORY-GROUPS { sysApplInstalledGroup,
                              sysApplRunGroup, sysApplMapGroup }
       ::= { sysApplMIBCompliances 1 }

   sysApplInstalledGroup OBJECT-GROUP
       OBJECTS { sysApplInstallPkgManufacturer,
                 sysApplInstallPkgProductName,
                 sysApplInstallPkgVersion,
                 sysApplInstallPkgSerialNumber,
                 sysApplInstallPkgDate,
                 sysApplInstallPkgLocation,
                 sysApplInstallElmtName,
                 sysApplInstallElmtType,
                 sysApplInstallElmtDate,
                 sysApplInstallElmtPath,
                 sysApplInstallElmtSizeHigh,
                 sysApplInstallElmtSizeLow,
                 sysApplInstallElmtRole,
                 sysApplInstallElmtModifyDate,
                 sysApplInstallElmtCurSizeHigh,
                 sysApplInstallElmtCurSizeLow }
       STATUS  current
       DESCRIPTION
           "The system application installed group contains
           information about applications and their constituent
           components which have been installed on the host system."
       ::= { sysApplMIBGroups 1 }

   sysApplRunGroup OBJECT-GROUP
       OBJECTS { sysApplRunStarted,
                 sysApplRunCurrentState,
                 sysApplPastRunStarted,
                 sysApplPastRunExitState,
                 sysApplPastRunTimeEnded,
                 sysApplElmtRunInstallID,
                 sysApplElmtRunTimeStarted,
                 sysApplElmtRunState,
                 sysApplElmtRunName,
                 sysApplElmtRunParameters,



Krupczak & Saperia          Standards Track                    [Page 38]


RFC 2287                  MIB for Applications             February 1998


                 sysApplElmtRunCPU,
                 sysApplElmtRunMemory,
                 sysApplElmtRunNumFiles,
                 sysApplElmtRunUser,
                 sysApplElmtPastRunInstallID,
                 sysApplElmtPastRunTimeStarted,
                 sysApplElmtPastRunTimeEnded,
                 sysApplElmtPastRunName,
                 sysApplElmtPastRunParameters,
                 sysApplElmtPastRunCPU,
                 sysApplElmtPastRunMemory,
                 sysApplElmtPastRunNumFiles,
                 sysApplElmtPastRunUser,
                 sysApplPastRunMaxRows,
                 sysApplPastRunTableRemItems,
                 sysApplPastRunTblTimeLimit,
                 sysApplElemPastRunMaxRows,
                 sysApplElemPastRunTableRemItems,
                 sysApplElemPastRunTblTimeLimit,
                 sysApplAgentPollInterval }
       STATUS  current
       DESCRIPTION
           "The system application run group contains information
           about applications and associated elements which have
           run or are currently running on the host system."
       ::= { sysApplMIBGroups 2 }

   sysApplMapGroup OBJECT-GROUP
       OBJECTS { sysApplMapInstallPkgIndex }
       STATUS  current
       DESCRIPTION
           "The Map Group contains a single table, sysApplMapTable,
           that provides a backwards mapping for determining the
           invoked application, installed element, and installed
           application package given a known process identification
           number."
   ::= { sysApplMIBGroups 3 }

   END












Krupczak & Saperia          Standards Track                    [Page 39]


RFC 2287                  MIB for Applications             February 1998


7.  Implementation Issues

   This section discusses implementation issues that are important for
   both an agent developer, and a management application developer or
   user to understand with regards to this MIB module.  Although this
   section does not attempt to prescribe a particular implementation
   strategy, it does attempt to recognize some of the real world
   limitations that could effect an implementation of this MIB module.

7.1.  Implementation with Polling Agents

   Implementations of the System Application MIB on popular operating
   systems might require some considerable processing power to obtain
   status information from the managed resources.  It might also be
   difficult to determine when an application or a process starts or
   finishes. Implementors of this MIB might therefore choose an
   implementation approach where the agent polls the managed resources
   at regular intervals. The information retrieved by every poll is used
   to update a cached version of this MIB maintained inside of the
   agent. SNMP request are processed based on the information found in
   this MIB cache.

   A scalar sysApplAgentPollInterval is defined to give the manager
   control over the polling frequency. There is a trade- off between the
   amount of resources consumed during every poll to update the MIB
   cache, and the accuracy of the information provided by the System
   Application MIB agent. A default value of 60 seconds is defined to
   keep the processing overhead low, while providing usable information
   for long-lived processes. A manager is expected to adjust this value
   if more accurate information about short-lived applications or
   processes is needed, or if the amount of resources consumed by the
   agent is too high.

7.2.  sysApplElmtPastRunTable Entry Collisions

   The sysApplElmtPastRunTable maintains a history of processes which
   have previously executed on the host as part of an application.
   Information is moved from the sysApplElmtRunTable to this PastRun
   table when the process represented by the entry terminates.

   The sysApplElmtPastRunTable is indexed by the tuple,
   (sysApplElmtPastRunInvocID, sysApplElmtPastRunIndex), where the first
   part identifies the application invocation of which the process was a
   part, and the second part identifies the process itself.

   Recall that the sysApplElmtRunIndex represents the system's unique
   identification number assigned to a running process and that this
   value is mapped to sysApplElmtPastRunIndex when the process



Krupczak & Saperia          Standards Track                    [Page 40]


RFC 2287                  MIB for Applications             February 1998


   terminates and the entry's information is moved from the
   sysApplElmtRunTable to the sysApplElmtPastRunTable.  Many systems
   re-use process ID numbers which are no longer assigned to running
   processes; typically, the process numbers wrap and the next available
   process number is used.

   It is therefore possible for two entries in the sysApplElmtPastRun
   Table to have the same value for sysApplElmtPastRunIndex.  For this
   reason, entries in the ElmtPastRun table are indexed by the tuple
   sysApplElmtPastRunInvocID, sysApplElmtPastRunIndex to reduce the
   chance of a collision by two past run elements with the same
   sysApplElmtPastRunIndex.

   However, it is still possible, though unlikely, for a collision to
   occur if the following happens:

   1)   the invoked application (identified by InvocID), has an
        element which runs, terminates, and is moved into the
        sysApplElmtPastRun table (index: InvocID, RunIndex)

   2)   the numbers used for the system's process identification
        numbering wrap

   3)   that same invoked application (same InvocID), has another
        element process run, AND that process is assigned the same
        identification number as one of the processes previously run by
        that invoked application (same RunIndex), and finally,

   4)   that element process terminates and is moved to the
        sysApplElmtPastRun table prior to the old, duplicate (InvocID,
        RunIndex) entry being aged out of the table by settings defined
        for sysApplElmtPastRunMaxRows and
        sysApplElmtPastRunTblTimeLimit.

   In the event that a collision occurs, the new entry will replace the
   old entry.

8.  Security Considerations

   In order to implement this MIB, an agent must make certain management
   information available about various logical and physical entities
   within a managed system which may be considered sensitive in some
   network environments.

   Therefore, a network administrator may wish to employ instance-level
   access control, and configure the access mechanism (i.e., community
   strings in SNMPv1 and SNMPv2C), such that certain instances within
   this MIB are excluded from particular MIB views.



Krupczak & Saperia          Standards Track                    [Page 41]


RFC 2287                  MIB for Applications             February 1998


9.  Acknowledgements

   This document was produced by the Application MIB working group.
   Special acknowledgement is made to:

     Rick Sturm
     Enterprise Management Professional Services, Inc.
     sturm@emi-summit.com
     For hosting the working group mailing list, and for his
     participation in the development of the initial draft.


     Jon Weinstock
     General Instrument Corporation
     jweinstock@gic.gi.com
     For his participation in the development of the initial drafts
     and for serving as editor for drafts 1 and 2.

     The editor would like to extend special thanks to the
     following working group members for their contributions
     to this effort.

     Harald Alvestrand, George Best, Ian Hanson, Harrie
     Hazewinkel, Carl Kalbfleisch, Bobby Krupczak, Randy
     Presuhn, Jon Saperia, Juergen Schoenwaelder

11.  Author's Address

   Cheryl Krupczak
   Empire Technologies, Inc.
   541 Tenth Street, NW Suite 169
   Atlanta, GA 30318

   Phone: 770.384.0184
   EMail: cheryl@empiretech.com

   Jonathan Saperia
   BGS Systems Inc.
   saperia@networks.bgs.com

12.  References

   [1]  Information processing systems - Open Systems
        Interconnection - Specification of Abstract Syntax
        Notation One (ASN.1), International Organization for
        Standardization.  International Standard 8824, (December,
        1987).




Krupczak & Saperia          Standards Track                    [Page 42]


RFC 2287                  MIB for Applications             February 1998


   [2]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Structure of Management Information
        for Version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1902, January 1996.

   [3]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Textual Conventions for Version 2 of
        the Simple Network Management Protocol (SNMPv2)", RFC
        1903, January 1996.

   [4]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Conformance Statements for Version 2
        of the Simple Network Management Protocol (SNMPv2)", RFC
        1904, January 1996.

   [5]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Protocol Operations for Version 2 of
        the Simple Network Management Protocol (SNMPv2)", RFC
        1905, January 1996.

   [6]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Transport Mappings for SNMPv2", RFC
        1906, January 1996.

   [7]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Management Information Base for
        Version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1907, January 1996.

   [8]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,
        and S. Waldbusser, "Coexistence between Version 1 and
        Version 2 of the Internet-standard Network Management
        Framework", RFC 1908, January 1996.

   [9]  Grillo, P., and S. Waldbusser, "Host Resources MIB", RFC 1514,
        September 1993.

   [10] Yergeau, F., "UTF-8, a transformation format of Unicode
        and ISO 10646", RFC 2044, October 1996.

   [11] Krupczak, C., and S. Waldbusser, "Applicability of Host
        Resources MIB to Application Management", Application MIB
        working group report, October 1995.








Krupczak & Saperia          Standards Track                    [Page 43]


RFC 2287                  MIB for Applications             February 1998


12.  Full Copyright Statement

   Copyright (C) The Internet Society (1998).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
























Krupczak & Saperia          Standards Track                    [Page 44]