[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

Obsoleted by: 4044 PROPOSED STANDARD
Network Working Group                                         K. S. Teow
Request for Comments: 2837          Brocade Communications Systems, Inc.
Category: Standards Track                                       May 2000


                     Definitions of Managed Objects
            for the Fabric Element in Fibre Channel Standard

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

Abstract

   This memo defines an extension to the Management Information Base
   (MIB) for use with network management protocols in TCP/IP-based
   internets.  In particular, it defines the objects for managing the
   operations of the Fabric Element portion of the Fibre Channel
   Standards.

Table of Contents

   1. The SNMP Management Framework ..................................2
   2. Overview .......................................................3
   2.1 Management View of a Fabric Element ...........................4
   2.2 Structure of the Fabric Element MIB ...........................5
   3. Object Definitions .............................................6
        The Configuration Group ......................................8
          The Module Table ...........................................9
          The FxPort Configuration Table ............................12
        The Status Group ............................................16
          The FxPort Status Table ...................................16
          The FxPort Physical Level Table ...........................18
          The FxPort Fabric Login Table .............................20
        The Error Group .............................................24
        The Accounting Groups........................................27
          The Class 1 Accounting Table ..............................27
          The Class 2 Accounting Table ..............................31
          The Class 3 Accounting Table ..............................33
        The Capability Group ........................................35



Teow                        Standards Track                     [Page 1]


RFC 2837                 FC Fabric Element MIB                  May 2000


        Conformance information .....................................38
   4. Security Considerations .......................................43
   5. Intellectual Property .........................................44
   6. Acknowledgements ..............................................44
   7. References ....................................................45
   7.1 IETF References ..............................................45
   7.2 Approved ANSI/NCITS References ...............................46
   7.3 ANSI/NCITS References Under Development ......................47
   8. Editors' Addresses ............................................47
   9. Full Copyright Statement ......................................48

1. The SNMP Management Framework

   The SNMP Management Framework presently consists of five major
   components:

   o  An overall architecture, described in RFC 2571 [1].

   o  Mechanisms for describing and naming objects and events for the
      purpose of management. The first version of this Structure of
      Management Information (SMI) is called SMIv1 and described in STD
      16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4]. The
      second version, called SMIv2, is described in STD 58, RFC 2578
      [5], STD 58, RFC 2579 [6] and STD 58, RFC 2580 [7].

   o  Message protocols for transferring management information.  The
      first version of the SNMP message protocol is called SNMPv1 and
      described in STD 15, RFC 1157 [8]. A second version of the SNMP
      message protocol, which is not an Internet standards track
      protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC
      1906 [10]. The third version of the message protocol is called
      SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574
      [12].

   o  Protocol operations for accessing management information. The
      first set of protocol operations and associated PDU formats is
      described in STD 15, RFC 1157 [8]. A second set of protocol
      operations and associated PDU formats is described in RFC 1905
      [13].

   o  A set of fundamental applications described in RFC 2573 [14] and
      the view-based access control mechanism described in RFC 2575
      [15].

   A more detailed introduction to the current SNMP Management Framework
   can be found in RFC 2570 [16].





Teow                        Standards Track                     [Page 2]


RFC 2837                 FC Fabric Element MIB                  May 2000


   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.

   This memo specifies a MIB module that is compliant to the SMIv2. A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations. The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (use of Counter64). Some machine readable
   information in SMIv2 will be converted into textual descriptions in
   SMIv1 during the translation process. However, this loss of machine
   readable information is not considered to change the semantics of the
   MIB.

2. Overview

   A Fibre Channel Fabric is an entity which interconnects Node Ports
   (N_Ports) or Node Loop Ports (NL_Ports).  It provides transport and
   routing functions.  In essence, a Fabric is a network of N_Ports
   and/or NL_Ports to communicate with one another.  A Fabric is
   composed of one or more Fabric Element that are interconnected via
   Inter-element Links (IEL).  A Fabric Element is the smallest unit of
   a Fabric that meets the definition of a Fabric.  It must consist of
   at least three external ports to connect to either N_Ports, NL_Ports
   or other Fabric Elements.  In general, a Fabric Element port may be
   of one of the following types:

   (1) F_Port, a fabric port to connect to an N_Port ([17], [21], [22]);

   (2)  FL_Port, a fabric port that also supports a FC Arbitrated Loop
       consisting of one or more NL_Ports ([20], [24]).

   (3)  E_Port, an expansion port to connect to another Fabric Element
       ([18], [23]);

   This memo shall define objects related to a Fabric Element, its
   F_Ports and FL_Ports.  Objects related to other types of FC ports
   shall be defined in future.

   For the rest of the document, the term, "FxPort", will be used to
   refer to both F_Port and FL_Port where the distinction is not
   necessary.  The term, "NxPort" will be used to refer to both N_Port
   and NL_Port in the similar fashion.








Teow                        Standards Track                     [Page 3]


RFC 2837                 FC Fabric Element MIB                  May 2000


2.1. Management View of a Fabric Element

   From the management perspective, it is helpful to view a Fabric
   Element to be consisting of multiple "modules".  Each module is a
   grouping, either physical or logical, of one or more ports that may
   be managed as a sub-entity within the Fabric Element.

   This module mapping is recommended but optional.  A vendor may elect
   to put all ports into a single module, or to divide the ports into
   modules that do not match physical divisions.

   The object fcFeModuleCapacity indicates the maximum number of modules
   that a given Fabric Element may contain.  This value must remain
   constant from one management restart to the next.

   Each module is uniquely identified by a module number in the range of
   1 through fcFeModuleCapacity inclusive.  Modules may come and go
   without causing a management reset (of sysUpTime), and may be
   sparsely numbered within the Fabric Element.  That is, the module
   numbering is not required to be contiguous.  For instance, if a
   module is mapped physically to a field-replaceable card and in a 13-
   card cage Fabric Element, cards 3, 5, 6 and 7 may be installed.  The
   vendor may choose to label them as modules 3, 5, 6 and 7
   respectively.  In this example, the value of fcFeModuleCapacity is
   13.  Note that the object fcFeModuleLastChange acts as the
   discontinuity indicator for all counter objects in this MIB.

   A Fabric Element may also provide a proxy management on behalf of
   another management entity by presenting it as one of its Fabric
   Element modules.

   The object fcFeModuleFxPortCapacity indicates the maximum number of
   ports that a given module may contain.  The value of
   fcFeModuleFxPortCapacity must not change for a given module.
   However, a module may be deleted from the Fabric Element and replaced
   with a module containing a different number of ports.  The value of
   fcFeModuleLastChange will indicate that a change took place.

   Each port within the Fabric Element is uniquely identified by a
   combination of module index and port index, where port index is an
   integer in the range (1..fcFeModuleFxPortCapacity).  As with modules
   within a Fabric Element, ports within a module may be sparsely
   numbered.  That is the port numbering is not required to be
   contiguous.  Likewise, ports may come and go within a module without
   causing a management reset.






Teow                        Standards Track                     [Page 4]


RFC 2837                 FC Fabric Element MIB                  May 2000


   In terms of attachment, an F_Port will be attached to another N_Port;
   and an FL_Port will be attached to one or up to 126 NL_Ports.  In
   general, an FxPort may be attached to one or more NxPorts.  Each
   NxPort associated with an FxPort will be uniquely identified by a
   combination of module index, FxPort index and NxPort index.  An
   NxPort index is an integer in the range (1..126).  The following
   diagram illustrates the management view of a Fabric Element.

           #=======================================================#
           #  +----------------- - - - -----------------+          #
           #  | Module 1 [1]     . . .            [i]   |          #
           #  +----------------- - - - -----------------+          #
           #                     o o o                             #
           #  +---------------------- - - - --------+              #
           #  | Module M [1]          . . .     [n] |              #
           #  +---------------------- - - - -----^--+              #
           #=====================================|=================#
                                                 |
        One or more NxPorts   { [1] . . . [L] }<-+
                              - - - - - - - - -
   where "i", "n", "M" and "L" are some arbitrary sample integer values,
   and "L" must be less than 127.

2.2. Structure of the Fabric Element MIB

   This memo assumes that a Fabric Element has an SNMP entity associated
   with its managed objects.  The managed objects are divided as follow:

         - the Configuration group
         - the Status group
         - the Error group
         - the Accounting group
         - the Capability group

   In each group, scalar objects and table entries are defined.

   The Configuration group contains configuration and service parameters
   for the Fabric Element, modules and the FxPorts.

   The Operation group contains the operational status and parameters of
   an FxPort.  The group also contains the service parameters that have
   been established between the FxPort and its attached NxPort, if
   applicable.

   The Error group contains counters tracking various types of errors
   detected by each FxPort.  The information may be used for diagnostics
   and/or to derive the quality of the link between an FxPort and one or
   more attached NxPorts.



Teow                        Standards Track                     [Page 5]


RFC 2837                 FC Fabric Element MIB                  May 2000


   The Accounting group contains statistic data suitable for deriving
   accounting and performance information.

   The Capability group contains parameters indicating the inherent
   capability of the Fabric Element and each FxPort.

3. Object Definitions

FIBRE-CHANNEL-FE-MIB DEFINITIONS ::= BEGIN
  IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Unsigned32, Counter32, Gauge32, Integer32, mib-2
      FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, TruthValue, TimeStamp
      FROM SNMPv2-TC
    SnmpAdminString
      FROM SNMP-FRAMEWORK-MIB                   -- rfc2571
    MODULE-COMPLIANCE, OBJECT-GROUP
      FROM SNMPv2-CONF;

  fcFeMIB MODULE-IDENTITY
    LAST-UPDATED "200005180000Z"
    ORGANIZATION "IETF IPFC Working Group"
    CONTACT-INFO "Kha Sin Teow
                  Brocade Communications Systems,
                  1901 Guadalupe Parkway,
                  San Jose, CA 95131
                  U.S.A
                  Tel: +1 408 487 8180
                  Fax: +1 408 487 8190
                  Email: khasin@Brocade.COM

                 WG Mailing list:ipfc@standards.gadzoox.com
                 To Subscribe: ipfc-request@standards.gadzoox.com
                 In Body: subscribe"

    DESCRIPTION "The MIB module for Fibre Channel Fabric Element."
    REVISION "200005180000Z"
    DESCRIPTION "Initial revision, published as RFC 2837."
    ::= { mib-2 75 }

  fcFeMIBObjects OBJECT IDENTIFIER ::= { fcFeMIB 1 }

   --  Note:
   --  fcFeMIBConformance OBJECT IDENTIFIER ::= { fcFeMIB 2 }
   --  see at the end of the module

  -- Groups under fcFeMIBObjects



Teow                        Standards Track                     [Page 6]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFeConfig       OBJECT IDENTIFIER ::= { fcFeMIBObjects 1 }
  fcFeStatus       OBJECT IDENTIFIER ::= { fcFeMIBObjects 2 }
  fcFeError        OBJECT IDENTIFIER ::= { fcFeMIBObjects 3 }
  fcFeAccounting   OBJECT IDENTIFIER ::= { fcFeMIBObjects 4 }
  fcFeCapabilities OBJECT IDENTIFIER ::= { fcFeMIBObjects 5 }

  -- Textual Conventions
  MilliSeconds ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents time unit value in milliseconds."
    SYNTAX         Unsigned32

  MicroSeconds ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents time unit value in microseconds."
    SYNTAX         Unsigned32

  FcNameId ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the Worldwide Name associated with
                    a Fibre Channel (FC) entity."
    SYNTAX         OCTET STRING (SIZE (8))

  FcAddressId ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents Fibre Channel Address ID, a 24-bit
                    value unique within the address space of a Fabric."
    SYNTAX         OCTET STRING (SIZE (3))

  FcRxDataFieldSize ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the receive data field size of an
                    NxPort or FxPort."
    SYNTAX         Integer32 (128..2112)

  FcBbCredit ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the buffer-to-buffer credit of an
                    NxPort or FxPort."
    SYNTAX         Integer32 (0..32767)

  FcphVersion ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the version of FC-PH supported by an
                    NxPort or FxPort."
    SYNTAX         Integer32 (0..255)

  FcStackedConnMode ::= TEXTUAL-CONVENTION



Teow                        Standards Track                     [Page 7]


RFC 2837                 FC Fabric Element MIB                  May 2000


    STATUS         current
    DESCRIPTION    "Represents an enumerated value used to indicate
                    the Class 1 Stacked Connect Mode supported by
                    an NxPort or FxPort."
    SYNTAX         INTEGER {
                        none(1),
                        transparent(2),
                        lockedDown(3)
    }

  FcCosCap ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the class of service capability of an
                    NxPort or FxPort."
    SYNTAX         BITS { classF(0), class1(1), class2(2), class3(3),
                          class4(4), class5(5), class6(6) }

  FcFeModuleCapacity ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the maximum number of modules within
                    a Fabric Element."
    SYNTAX         Unsigned32

  FcFeFxPortCapacity ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the maximum number of FxPorts within
                    a module."
    SYNTAX         Unsigned32

  FcFeModuleIndex ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the module index within a conceptual table."
    SYNTAX         Unsigned32

  FcFeFxPortIndex ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the FxPort index within a conceptual table."
    SYNTAX         Unsigned32

  FcFeNxPortIndex ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the NxPort index within a conceptual table."
    SYNTAX         Integer32 (1..126)

  FcBbCreditModel ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Represents the BB_Credit model of an FxPort."
    SYNTAX         INTEGER { regular(1), alternate (2) }



Teow                        Standards Track                     [Page 8]


RFC 2837                 FC Fabric Element MIB                  May 2000


  -- The Configuration group

  -- This group consists of scalar objects and tables.
  -- It contains the configuration and service parameters
  -- of the Fabric Element and the FxPorts.
  -- The group represents a set of parameters associated with
  -- the Fabric Element  or an FxPort to support its NxPorts.

  fcFeFabricName OBJECT-TYPE
      SYNTAX      FcNameId
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
         "The Name_Identifier of the Fabric to which this Fabric
          Element belongs."
  ::= { fcFeConfig 1 }

  fcFeElementName OBJECT-TYPE
      SYNTAX      FcNameId
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
         "The Name_Identifier of the Fabric Element."
  ::= { fcFeConfig 2 }

  fcFeModuleCapacity OBJECT-TYPE
      SYNTAX      FcFeModuleCapacity
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The maximum number of modules in the Fabric Element,
          regardless of their current state."
  ::= { fcFeConfig 3 }

  -- The Module Table.
  -- This table contains one entry for each module,
  -- information of the modules.

  fcFeModuleTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFeModuleEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each module in the
          Fabric Element, information of the modules."
  ::= { fcFeConfig 4 }

  fcFeModuleEntry OBJECT-TYPE



Teow                        Standards Track                     [Page 9]


RFC 2837                 FC Fabric Element MIB                  May 2000


      SYNTAX      FcFeModuleEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing the configuration parameters of a
          module."
      INDEX { fcFeModuleIndex }
  ::= { fcFeModuleTable 1 }


  FcFeModuleEntry ::=
      SEQUENCE {
          fcFeModuleIndex
              FcFeModuleIndex,
          fcFeModuleDescr
              SnmpAdminString,
          fcFeModuleObjectID
              OBJECT IDENTIFIER,
          fcFeModuleOperStatus
              INTEGER,
          fcFeModuleLastChange
              TimeStamp,
          fcFeModuleFxPortCapacity
              FcFeFxPortCapacity,
          fcFeModuleName
              FcNameId
      }

  fcFeModuleIndex OBJECT-TYPE
      SYNTAX      FcFeModuleIndex
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "This object identifies the module within the Fabric Element
          for which this entry contains information. This value is
          never greater than fcFeModuleCapacity."
  ::= { fcFeModuleEntry 1 }

  fcFeModuleDescr OBJECT-TYPE
      SYNTAX      SnmpAdminString
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A textual description of the module. This value should
          include the full name and version identification of the
          module."
  ::= { fcFeModuleEntry 2 }




Teow                        Standards Track                    [Page 10]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFeModuleObjectID OBJECT-TYPE
      SYNTAX      OBJECT IDENTIFIER
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The vendor's authoritative identification of the module.
          This value may be allocated within the SMI enterprises
          subtree (1.3.6.1.4.1) and provides a straight-forward and
          unambiguous means for determining what kind of module is
          being managed.

          For example, this object could take the value
          1.3.6.1.4.1.99649.3.9 if vendor 'Neufe Inc.' was assigned
          the subtree 1.3.6.1.4.1.99649, and had assigned the
          identifier 1.3.6.1.4.1.99649.3.9 to its 'FeFiFo-16
          PlugInCard.'"
  ::= { fcFeModuleEntry 3 }

  fcFeModuleOperStatus    OBJECT-TYPE
      SYNTAX      INTEGER {
                      online  (1), -- functional
                      offline (2), -- not available
                      testing (3), -- under testing
                      faulty  (4)  -- defective
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This object indicates the operational status of the module:
          online(1)   the module is functioning properly;
          offline(2)  the module is not available;
          testing(3)  the module is under testing; and
          faulty(4)   the module is defective in some way."
  ::= { fcFeModuleEntry 4 }

  fcFeModuleLastChange OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This object contains the value of sysUpTime when the module
          entered its current operational status. A value of zero
          indicates that the operational status of the module has not
          changed since the agent last restarted."
  ::= { fcFeModuleEntry 5 }

  fcFeModuleFxPortCapacity OBJECT-TYPE
      SYNTAX      FcFeFxPortCapacity



Teow                        Standards Track                    [Page 11]


RFC 2837                 FC Fabric Element MIB                  May 2000


      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of FxPort that can be contained within the
          module. Within each module, the ports are uniquely numbered
          in the range from 1 to fcFeModuleFxPortCapacity inclusive.
          However, the numbers are not required to be contiguous."
  ::= { fcFeModuleEntry 6 }

  fcFeModuleName OBJECT-TYPE
      SYNTAX      FcNameId
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
         "The Name_Identifier of the module."
  ::= { fcFeModuleEntry 7 }

  -- the FxPort Configuration Table.
  -- This table contains, one entry for each FxPort,
  -- configuration parameters of the ports.

 fcFxPortTable OBJECT-TYPE
     SYNTAX      SEQUENCE OF FcFxPortEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
        "A table that contains, one entry for each FxPort in the
         Fabric Element, configuration and service parameters of the
         FxPorts."
 ::= { fcFeConfig 5 }

 fcFxPortEntry OBJECT-TYPE
     SYNTAX      FcFxPortEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
        "An entry containing the configuration and service parameters
         of a FxPort."
     INDEX { fcFeModuleIndex, fcFxPortIndex }
 ::= { fcFxPortTable 1 }


 FcFxPortEntry ::=
     SEQUENCE {
         fcFxPortIndex
             FcFeFxPortIndex,
         fcFxPortName
             FcNameId,



Teow                        Standards Track                    [Page 12]


RFC 2837                 FC Fabric Element MIB                  May 2000


         -- FxPort common service parameters
         fcFxPortFcphVersionHigh
             FcphVersion,
         fcFxPortFcphVersionLow
             FcphVersion,
         fcFxPortBbCredit
             FcBbCredit,
         fcFxPortRxBufSize
             FcRxDataFieldSize,
         fcFxPortRatov
             MilliSeconds,
         fcFxPortEdtov
             MilliSeconds,
         -- FxPort class service parameters
         fcFxPortCosSupported
             FcCosCap,
         fcFxPortIntermixSupported
             TruthValue,
         fcFxPortStackedConnMode
             FcStackedConnMode,
         fcFxPortClass2SeqDeliv
             TruthValue,
         fcFxPortClass3SeqDeliv
             TruthValue,
         -- other configuration parameters
         fcFxPortHoldTime
             MicroSeconds
     }

  fcFxPortIndex OBJECT-TYPE
      SYNTAX      FcFeFxPortIndex
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "This object identifies the FxPort within the module.  This
          number ranges from 1 to the value of fcFeModulePortCapacity
          for the associated module. The value remains constant for
          the identified FxPort until the module is re-initialized."
  ::= { fcFxPortEntry 1 }

  fcFxPortName OBJECT-TYPE
      SYNTAX      FcNameId
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The World_wide Name of this FxPort.  Each FxPort has a
          unique Port World_wide Name within the Fabric."
  ::= { fcFxPortEntry 2 }



Teow                        Standards Track                    [Page 13]


RFC 2837                 FC Fabric Element MIB                  May 2000


  -- FxPort common service parameters

  fcFxPortFcphVersionHigh OBJECT-TYPE
      SYNTAX      FcphVersion
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The highest or most recent version of FC-PH that the FxPort
          is configured to support."
  ::= { fcFxPortEntry 3 }

  fcFxPortFcphVersionLow OBJECT-TYPE
      SYNTAX      FcphVersion
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The lowest or earliest version of FC-PH that the FxPort is
          configured to support."
  ::= { fcFxPortEntry 4 }

  fcFxPortBbCredit OBJECT-TYPE
      SYNTAX      FcBbCredit
      UNITS       "buffers"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The total number of receive buffers available for holding
          Class 1 connect-request, Class 2 or 3 frames from the
          attached NxPort.  It is for buffer-to-buffer flow control
          in the direction from the attached NxPort (if applicable)
          to FxPort."
      ::= { fcFxPortEntry 5 }

  fcFxPortRxBufSize OBJECT-TYPE
      SYNTAX      FcRxDataFieldSize
      UNITS       "bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The largest Data_Field Size (in octets) for an FT_1 frame
          that can be received by the FxPort."
  ::= { fcFxPortEntry 6 }

  fcFxPortRatov OBJECT-TYPE
      SYNTAX      MilliSeconds
      UNITS       "milliseconds"
      MAX-ACCESS  read-only
      STATUS      current



Teow                        Standards Track                    [Page 14]


RFC 2837                 FC Fabric Element MIB                  May 2000


      DESCRIPTION
         "The Resource_Allocation_Timeout Value configured for the
          FxPort.  This is used as the timeout value for determining
          when to reuse an NxPort resource such as a
          Recovery_Qualifier.  It represents E_D_TOV (see next
          object) plus twice the maximum time that a frame may be
          delayed within the Fabric and still be delivered."
      ::= { fcFxPortEntry 7 }

  fcFxPortEdtov OBJECT-TYPE
      SYNTAX      MilliSeconds
      UNITS       "milliseconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The E_D_TOV value configured for the FxPort. The
          Error_Detect_Timeout Value is used as the timeout value for
          detecting an error condition."
  ::= { fcFxPortEntry 8 }


  -- FxPort class service parameters

  fcFxPortCosSupported OBJECT-TYPE
      SYNTAX      FcCosCap
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A value indicating the set of Classes of Service supported
          by the FxPort."
  ::= { fcFxPortEntry 9 }

  fcFxPortIntermixSupported OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether or not the FxPort supports an
          Intermixed Dedicated Connection."
  ::= { fcFxPortEntry 10 }

  fcFxPortStackedConnMode OBJECT-TYPE
      SYNTAX      FcStackedConnMode
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A value indicating the mode of Stacked Connect supported by
          the FxPort."



Teow                        Standards Track                    [Page 15]


RFC 2837                 FC Fabric Element MIB                  May 2000


  ::= { fcFxPortEntry 11 }

  fcFxPortClass2SeqDeliv OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether or not Class 2 Sequential
          Delivery is supported by the FxPort."
  ::= { fcFxPortEntry 12 }

  fcFxPortClass3SeqDeliv OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether or not Class 3 Sequential
          Delivery is supported by the FxPort."
  ::= { fcFxPortEntry 13 }


  -- other FxPort parameters

  fcFxPortHoldTime OBJECT-TYPE
      SYNTAX      MicroSeconds
      UNITS       "microseconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The maximum time (in microseconds) that the FxPort shall
          hold a frame before discarding the frame if it is unable to
          deliver the frame. The value 0 means that the FxPort does
          not support this parameter."
  ::= { fcFxPortEntry 14 }


  -- the Status group

  -- This group consists of tables that contains operational
  -- status and established service parameters for the Fabric
  -- Element and the attached NxPorts.

  -- The FxPort Status table
  -- This table contains, one entry for each FxPort,
  -- the operational status and parameters of the FxPorts.

  fcFxPortStatusTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortStatusEntry



Teow                        Standards Track                    [Page 16]


RFC 2837                 FC Fabric Element MIB                  May 2000


      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort in the
          Fabric Element, operational status and parameters of the
          FxPorts."
  ::= { fcFeStatus 1 }

  fcFxPortStatusEntry OBJECT-TYPE
      SYNTAX      FcFxPortStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing operational status and parameters of a
          FxPort."
      AUGMENTS { fcFxPortEntry }
  ::= { fcFxPortStatusTable 1 }


  FcFxPortStatusEntry ::=
      SEQUENCE {
          fcFxPortID
              FcAddressId,
          fcFxPortBbCreditAvailable
              Gauge32,
          fcFxPortOperMode
              INTEGER,
          fcFxPortAdminMode
              INTEGER
      }

  fcFxPortID   OBJECT-TYPE
      SYNTAX      FcAddressId
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The address identifier by which this FxPort is identified
          within the Fabric.  The FxPort may assign its address
          identifier to its attached NxPort(s) during Fabric Login."
  ::= { fcFxPortStatusEntry 1 }

  fcFxPortBbCreditAvailable OBJECT-TYPE
      SYNTAX      Gauge32
      UNITS       "buffers"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of buffers currently available for receiving



Teow                        Standards Track                    [Page 17]


RFC 2837                 FC Fabric Element MIB                  May 2000


          frames from the attached port in the buffer-to-buffer flow
          control. The value should be less than or equal to
          fcFxPortBbCredit."
  ::= { fcFxPortStatusEntry 2 }

  fcFxPortOperMode    OBJECT-TYPE
      SYNTAX              INTEGER { unknown(1), fPort(2), flPort(3) }
      MAX-ACCESS          read-only
      STATUS              current
      DESCRIPTION
         "The current operational mode of the FxPort."
  ::= { fcFxPortStatusEntry 3 }

  fcFxPortAdminMode   OBJECT-TYPE
      SYNTAX              INTEGER { fPort(2), flPort(3) }
      MAX-ACCESS          read-write
      STATUS              current
      DESCRIPTION
         "The desired operational mode of the FxPort."
  ::= { fcFxPortStatusEntry 4 }


  -- the FxPort Physical Level table
  -- This table contains, one entry for each FxPort in the
  -- Fabric Element, the physical level status and parameters
  -- of the FxPorts.

  fcFxPortPhysTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortPhysEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort in the
          Fabric Element, physical level status and parameters of the
          FxPorts."
  ::= { fcFeStatus 2 }

  fcFxPortPhysEntry OBJECT-TYPE
      SYNTAX      FcFxPortPhysEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing physical level status and parameters of
          a FxPort."
      AUGMENTS { fcFxPortEntry }
  ::= { fcFxPortPhysTable 1 }

  FcFxPortPhysEntry ::=



Teow                        Standards Track                    [Page 18]


RFC 2837                 FC Fabric Element MIB                  May 2000


      SEQUENCE {
          fcFxPortPhysAdminStatus
              INTEGER,
          fcFxPortPhysOperStatus
              INTEGER,
          fcFxPortPhysLastChange
              TimeStamp,
          fcFxPortPhysRttov
              MilliSeconds
      }

  fcFxPortPhysAdminStatus OBJECT-TYPE
      SYNTAX      INTEGER {
                      online  (1),  -- place port online
                      offline (2),  -- take port offline
                      testing (3)   -- initiate test procedures
                  }
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
         "The desired state of the FxPort.  A management station may
          place the FxPort in a desired state by setting this object
          accordingly.  The testing(3) state indicates that no
          operational frames can be passed.  When a Fabric Element
          initializes, all FxPorts start with fcFxPortPhysAdminStatus
          in the offline(2) state.  As the result of either explicit
          management action or per configuration information
          accessible by the Fabric Element, fcFxPortPhysAdminStatus
          is then changed to either the online(1) or testing(3)
          states, or remains in the offline state."
  ::= { fcFxPortPhysEntry 1 }

  fcFxPortPhysOperStatus   OBJECT-TYPE
      SYNTAX      INTEGER {
          online       (1), -- Login may proceed
          offline      (2), -- Login cannot proceed
          testing      (3), -- port is under test
          linkFailure  (4)  -- failure after online/testing
      }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The current operational status of the FxPort.  The
          testing(3) indicates that no operational frames can be
          passed.  If fcFxPortPhysAdminStatus is offline(2) then
          fcFxPortPhysOperStatus should be offline(2). If
          fcFxPortPhysAdminStatus is changed to online(1) then
          fcFxPortPhysOperStatus should change to online(1) if the



Teow                        Standards Track                    [Page 19]


RFC 2837                 FC Fabric Element MIB                  May 2000


          FxPort is ready to accept Fabric Login request from the
          attached NxPort; it should proceed and remain in the link-
          failure(4) state if and only if there is a fault that
          prevents it from going to the online(1) state."
  ::= { fcFxPortPhysEntry 2 }

  fcFxPortPhysLastChange OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The value of sysUpTime at the time the FxPort entered its
          current operational status. A value of zero indicates that
          the FxPort's operational status has not changed since the
          agent last restarted."
  ::= { fcFxPortPhysEntry 3 }

  fcFxPortPhysRttov OBJECT-TYPE
      SYNTAX      MilliSeconds
      UNITS       "milliseconds"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
         "The Receiver_Transmitter_Timeout value of the FxPort. This
          is used by the receiver logic to detect Loss of
          Synchronization."
  ::= { fcFxPortPhysEntry 4 }

  -- The FxPort Fabric Login table
  --
  -- This table contains, one entry for each FxPort in the
  -- Fabric Element, the Service Parameters that have been
  -- established from the most recent Fabric Login,
  -- implicit or explicit.

  fcFxLoginTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxLoginEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each NxPort attached
          to a particular FxPort in the Fabric Element, services
          parameters established from the most recent Fabric Login,
          explicit or implicit. Note that an FxPort may have one or
          more NxPort attached to it."
  ::= { fcFeStatus 3 }





Teow                        Standards Track                    [Page 20]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFxLoginEntry OBJECT-TYPE
      SYNTAX      FcFxLoginEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing service parameters established from a
          successful Fabric Login."
      INDEX { fcFeModuleIndex, fcFxPortIndex, fcFxPortNxLoginIndex }
  ::= { fcFxLoginTable 1 }

  FcFxLoginEntry ::=
      SEQUENCE {
          fcFxPortNxLoginIndex
              FcFeNxPortIndex,
          fcFxPortFcphVersionAgreed
              FcphVersion,
          fcFxPortNxPortBbCredit
              FcBbCredit,
          fcFxPortNxPortRxDataFieldSize
              FcRxDataFieldSize,
          fcFxPortCosSuppAgreed
              FcCosCap,
          fcFxPortIntermixSuppAgreed
              TruthValue,
          fcFxPortStackedConnModeAgreed
              FcStackedConnMode,
          fcFxPortClass2SeqDelivAgreed
              TruthValue,
          fcFxPortClass3SeqDelivAgreed
              TruthValue,
          --
          fcFxPortNxPortName
              FcNameId,
          fcFxPortConnectedNxPort
              FcAddressId,
          fcFxPortBbCreditModel
              FcBbCreditModel
      }

  fcFxPortNxLoginIndex OBJECT-TYPE
      SYNTAX      FcFeNxPortIndex
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "The object identifies the associated NxPort in the
          attachment for which the entry contains information."
  ::= { fcFxLoginEntry 1 }




Teow                        Standards Track                    [Page 21]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFxPortFcphVersionAgreed OBJECT-TYPE
      SYNTAX      FcphVersion
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The version of FC-PH that the FxPort has agreed to support
          from the Fabric Login"
  ::= { fcFxLoginEntry 2 }

  fcFxPortNxPortBbCredit OBJECT-TYPE
      SYNTAX      FcBbCredit
      UNITS       "buffers"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The total number of buffers available for holding Class 1
          connect-request, Class 2 or Class 3 frames to be
          transmitted to the attached NxPort.  It is for buffer-to-
          buffer flow control in the direction from FxPort to NxPort.
          The buffer-to-buffer flow control mechanism is indicated in
          the respective fcFxPortBbCreditModel."
  ::= { fcFxLoginEntry 3 }

  fcFxPortNxPortRxDataFieldSize OBJECT-TYPE
      SYNTAX      FcRxDataFieldSize
      UNITS       "bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The Receive Data Field Size of the attached NxPort. This
          object specifies the largest Data Field Size for an FT_1
          frame that can be received by the NxPort."
  ::= { fcFxLoginEntry 4 }

  fcFxPortCosSuppAgreed OBJECT-TYPE
      SYNTAX      FcCosCap
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A variable indicating that the attached NxPort has
          requested the FxPort for the support of classes of services
          and the FxPort has granted the request."
  ::= { fcFxLoginEntry 5 }

  fcFxPortIntermixSuppAgreed OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current



Teow                        Standards Track                    [Page 22]


RFC 2837                 FC Fabric Element MIB                  May 2000


      DESCRIPTION
         "A variable indicating that the attached NxPort has
          requested the FxPort for the support of Intermix and the
          FxPort has granted the request. This flag is only valid if
          Class 1 service is supported."
  ::= { fcFxLoginEntry 6 }

  fcFxPortStackedConnModeAgreed OBJECT-TYPE
      SYNTAX      FcStackedConnMode
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A variable indicating whether the FxPort has agreed to
          support stacked connect from the Fabric Login. This is only
          meaningful if Class 1 service has been agreed."
  ::= { fcFxLoginEntry 7 }

  fcFxPortClass2SeqDelivAgreed OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A variable indicating whether the FxPort has agreed to
          support Class 2 sequential delivery from the Fabric Login.
          This is only meaningful if Class 2 service has been
          agreed."
  ::= { fcFxLoginEntry 8 }

  fcFxPortClass3SeqDelivAgreed OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether the FxPort has agreed to support
          Class 3 sequential delivery from the Fabric Login. This is
          only meaningful if Class 3 service has been agreed."
  ::= { fcFxLoginEntry 9 }

  fcFxPortNxPortName OBJECT-TYPE
      SYNTAX      FcNameId
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The port name of the attached NxPort."
  ::= { fcFxLoginEntry 10 }

  fcFxPortConnectedNxPort OBJECT-TYPE
      SYNTAX      FcAddressId



Teow                        Standards Track                    [Page 23]


RFC 2837                 FC Fabric Element MIB                  May 2000


      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The address identifier of the destination NxPort with which
          this FxPort is currently engaged in a either a Class 1 or
          loop connection. If this FxPort is not engaged in a
          connection, then the value of this object is '000000'H."
  ::= { fcFxLoginEntry 11 }

  fcFxPortBbCreditModel OBJECT-TYPE
      SYNTAX      FcBbCreditModel
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
         "This object identifies the BB_Credit model used by the
          FxPort."
  ::= { fcFxLoginEntry 12 }


  -- the Error group
  -- This group consists of tables that contain information about
  -- the various types of errors detected.  The management station
  -- may use the information in this group to determine the
  -- quality of the link between the FxPort and its attached NxPort.

  -- the FxPort Error table
  -- This table contains, one entry for each FxPort in the Fabric
  -- Element, counters recording numbers of errors detected
  -- since the management agent re-initialized.
  -- The first 6 columnar objects after the port index corresponds
  -- to the counters in the Link Error Status Block.

  fcFxPortErrorTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortErrorEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort, counters
          that record the numbers of errors detected."
  ::= { fcFeError 1 }

  fcFxPortErrorEntry OBJECT-TYPE
      SYNTAX      FcFxPortErrorEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing error counters of a FxPort."
      AUGMENTS { fcFxPortEntry }



Teow                        Standards Track                    [Page 24]


RFC 2837                 FC Fabric Element MIB                  May 2000


  ::= { fcFxPortErrorTable 1 }


  FcFxPortErrorEntry ::=
      SEQUENCE {
          fcFxPortLinkFailures
              Counter32,
          fcFxPortSyncLosses
              Counter32,
          fcFxPortSigLosses
              Counter32,
          fcFxPortPrimSeqProtoErrors
              Counter32,
          fcFxPortInvalidTxWords
              Counter32,
          fcFxPortInvalidCrcs
              Counter32,
          fcFxPortDelimiterErrors
              Counter32,
          fcFxPortAddressIdErrors
              Counter32,
          fcFxPortLinkResetIns
              Counter32,
          fcFxPortLinkResetOuts
              Counter32,
          fcFxPortOlsIns
              Counter32,
          fcFxPortOlsOuts
              Counter32
      }

  fcFxPortLinkFailures OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of link failures detected by this FxPort."
  ::= { fcFxPortErrorEntry 1 }

  fcFxPortSyncLosses OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of loss of synchronization detected by the
          FxPort."
  ::= { fcFxPortErrorEntry 2 }




Teow                        Standards Track                    [Page 25]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFxPortSigLosses OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of loss of signal detected by the FxPort."
  ::= { fcFxPortErrorEntry 3 }

  fcFxPortPrimSeqProtoErrors OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of primitive sequence protocol errors detected
          by the FxPort."
  ::= { fcFxPortErrorEntry 4 }

  fcFxPortInvalidTxWords OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of invalid transmission word detected by the
          FxPort."
  ::= { fcFxPortErrorEntry 5 }

  fcFxPortInvalidCrcs OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of invalid CRC detected by this FxPort."
  ::= { fcFxPortErrorEntry 6 }

  fcFxPortDelimiterErrors OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Delimiter Errors detected by this FxPort."
  ::= { fcFxPortErrorEntry 7 }

  fcFxPortAddressIdErrors OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of address identifier errors detected by this



Teow                        Standards Track                    [Page 26]


RFC 2837                 FC Fabric Element MIB                  May 2000


          FxPort."
  ::= { fcFxPortErrorEntry 8 }

  fcFxPortLinkResetIns OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Link Reset Protocol received by this FxPort
          from the attached NxPort."
  ::= { fcFxPortErrorEntry 9 }

  fcFxPortLinkResetOuts OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Link Reset Protocol issued by this FxPort to
          the attached NxPort."
  ::= { fcFxPortErrorEntry 10 }

  fcFxPortOlsIns OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Offline Sequence received by this FxPort."
  ::= { fcFxPortErrorEntry 11 }

  fcFxPortOlsOuts OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Offline Sequence issued by this FxPort."
  ::= { fcFxPortErrorEntry 12 }



  -- Accounting Groups:
  -- (1) Class 1 Accounting Group,
  -- (2) Class 2 Accounting Group, and
  -- (3) Class 3 Accounting Group.
  -- Each group consists of a table that contains accounting
  -- information for the FxPorts in the Fabric Element.

  -- the Class 1 Accounting table
  -- This table contains, one entry for each FxPort in the Fabric



Teow                        Standards Track                    [Page 27]


RFC 2837                 FC Fabric Element MIB                  May 2000


  -- Element, Counter32s for certain types of events occurred in the
  -- the FxPorts since the the management agent has re-initialized.

  fcFxPortC1AccountingTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortC1AccountingEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort in the
          Fabric Element, Class 1 accounting information recorded
          since the management agent has re-initialized."
  ::= { fcFeAccounting 1 }

  fcFxPortC1AccountingEntry OBJECT-TYPE
      SYNTAX      FcFxPortC1AccountingEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing Class 1 accounting information for each
          FxPort."
      AUGMENTS { fcFxPortEntry }
  ::= { fcFxPortC1AccountingTable 1 }


  FcFxPortC1AccountingEntry ::=
      SEQUENCE {
          fcFxPortC1InFrames
              Counter32,
          fcFxPortC1OutFrames
              Counter32,
          fcFxPortC1InOctets
              Counter32,
          fcFxPortC1OutOctets
              Counter32,
          fcFxPortC1Discards
              Counter32,
          fcFxPortC1FbsyFrames
              Counter32,
          fcFxPortC1FrjtFrames
              Counter32,
          fcFxPortC1InConnections
              Counter32,
          fcFxPortC1OutConnections
              Counter32,
          fcFxPortC1ConnTime
              MilliSeconds
      }




Teow                        Standards Track                    [Page 28]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFxPortC1InFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 frames (other than Class 1 connect-
          request) received by this FxPort from its attached NxPort."
  ::= { fcFxPortC1AccountingEntry 1 }

  fcFxPortC1OutFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 frames (other than Class 1 connect-
          request) delivered through this FxPort to its attached
          NxPort."
  ::= { fcFxPortC1AccountingEntry 2 }

  fcFxPortC1InOctets OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 frame octets, including the frame
          delimiters,  received by this FxPort from its attached
          NxPort."
  ::= { fcFxPortC1AccountingEntry 3 }

  fcFxPortC1OutOctets OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 frame octets, including the frame
          delimiters, delivered through this FxPort its attached
          NxPort."
  ::= { fcFxPortC1AccountingEntry 4 }

  fcFxPortC1Discards OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 frames discarded by this FxPort."
  ::= { fcFxPortC1AccountingEntry 5 }

  fcFxPortC1FbsyFrames OBJECT-TYPE



Teow                        Standards Track                    [Page 29]


RFC 2837                 FC Fabric Element MIB                  May 2000


      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of F_BSY frames generated by this FxPort against
          Class 1 connect-request."
  ::= { fcFxPortC1AccountingEntry 6 }

  fcFxPortC1FrjtFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of F_RJT frames generated by this FxPort against
          Class 1 connect-request."
  ::= { fcFxPortC1AccountingEntry 7 }

  fcFxPortC1InConnections OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 connections successfully established
          in which the attached NxPort is the source of the connect-
          request."
  ::= { fcFxPortC1AccountingEntry 8 }

  fcFxPortC1OutConnections OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 1 connections successfully established
          in which the attached NxPort is the destination of the
          connect-request."
  ::= { fcFxPortC1AccountingEntry 9 }

  fcFxPortC1ConnTime OBJECT-TYPE
      SYNTAX      MilliSeconds
      UNITS       "milliseconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The cumulative time that this FxPort has been engaged in
          Class 1 connection.  The amount of time is counted from
          after a connect-request has been accepted until the
          connection is disengaged, either by an EOFdt or Link
          Reset."



Teow                        Standards Track                    [Page 30]


RFC 2837                 FC Fabric Element MIB                  May 2000


  ::= { fcFxPortC1AccountingEntry 10 }


  -- the Class 2 Accounting table
  -- This table contains, one entry for each FxPort in the Fabric
  -- Element, Counter32s for certain types of events occurred in the
  -- the FxPorts since the the management agent has re-initialized.


  fcFxPortC2AccountingTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortC2AccountingEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort in the
          Fabric Element, Class 2 accounting information recorded
          since the management agent has re-initialized."
  ::= { fcFeAccounting 2 }

  fcFxPortC2AccountingEntry OBJECT-TYPE
      SYNTAX      FcFxPortC2AccountingEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing Class 2 accounting information for each
          FxPort."
      AUGMENTS { fcFxPortEntry }
  ::= { fcFxPortC2AccountingTable 1 }

  FcFxPortC2AccountingEntry ::=
      SEQUENCE {
          fcFxPortC2InFrames
              Counter32,
          fcFxPortC2OutFrames
                 Counter32,
          fcFxPortC2InOctets
                 Counter32,
          fcFxPortC2OutOctets
                 Counter32,
          fcFxPortC2Discards
                 Counter32,
          fcFxPortC2FbsyFrames
                 Counter32,
          fcFxPortC2FrjtFrames
                 Counter32
      }

  fcFxPortC2InFrames OBJECT-TYPE



Teow                        Standards Track                    [Page 31]


RFC 2837                 FC Fabric Element MIB                  May 2000


      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 2 frames received by this FxPort from
          its attached NxPort."
  ::= { fcFxPortC2AccountingEntry 1 }

  fcFxPortC2OutFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 2 frames delivered through this FxPort
          to its attached NxPort."
  ::= { fcFxPortC2AccountingEntry 2 }

  fcFxPortC2InOctets OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 2 frame octets, including the frame
          delimiters, received by this FxPort from its attached
          NxPort."
  ::= { fcFxPortC2AccountingEntry 3 }

  fcFxPortC2OutOctets OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 2 frame octets, including the frame
          delimiters, delivered through this FxPort to its attached
          NxPort."
  ::= { fcFxPortC2AccountingEntry 4 }

  fcFxPortC2Discards OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 2 frames discarded by this FxPort."
  ::= { fcFxPortC2AccountingEntry 5 }

  fcFxPortC2FbsyFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only



Teow                        Standards Track                    [Page 32]


RFC 2837                 FC Fabric Element MIB                  May 2000


      STATUS      current
      DESCRIPTION
         "The number of F_BSY frames generated by this FxPort against
          Class 2 frames."
  ::= { fcFxPortC2AccountingEntry 6 }

  fcFxPortC2FrjtFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of F_RJT frames generated by this FxPort against
          Class 2 frames."
  ::= { fcFxPortC2AccountingEntry 7 }

  -- the Class 3 Accounting Group
  -- This table contains, one entry for each FxPort in the Fabric
  -- Element, Counter32s for certain types of events occurred in the
  -- the FxPorts since the management agent has re-initialized.

  fcFxPortC3AccountingTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortC3AccountingEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort in the
          Fabric Element, Class 3 accounting information recorded
          since the management agent has re-initialized."
  ::= { fcFeAccounting 3 }

  fcFxPortC3AccountingEntry OBJECT-TYPE
      SYNTAX      FcFxPortC3AccountingEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing Class 3 accounting information for each
          FxPort."
      AUGMENTS { fcFxPortEntry }
  ::= { fcFxPortC3AccountingTable 1 }


  FcFxPortC3AccountingEntry ::=
      SEQUENCE {
          fcFxPortC3InFrames
              Counter32,
          fcFxPortC3OutFrames
              Counter32,
          fcFxPortC3InOctets



Teow                        Standards Track                    [Page 33]


RFC 2837                 FC Fabric Element MIB                  May 2000


              Counter32,
          fcFxPortC3OutOctets
              Counter32,
          fcFxPortC3Discards
              Counter32
      }

  fcFxPortC3InFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 3 frames received by this FxPort from
          its attached NxPort."
  ::= { fcFxPortC3AccountingEntry 1 }

  fcFxPortC3OutFrames OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 3 frames delivered through this FxPort
          to its attached NxPort."
  ::= { fcFxPortC3AccountingEntry 2 }

  fcFxPortC3InOctets OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 3 frame octets, including the frame
          delimiters, received by this FxPort from its attached
          NxPort."
  ::= { fcFxPortC3AccountingEntry 3 }

  fcFxPortC3OutOctets OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The number of Class 3 frame octets, including the frame
          delimiters, delivered through this FxPort to its attached
          NxPort."
  ::= { fcFxPortC3AccountingEntry 4 }

  fcFxPortC3Discards OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only



Teow                        Standards Track                    [Page 34]


RFC 2837                 FC Fabric Element MIB                  May 2000


      STATUS      current
      DESCRIPTION
         "The number of Class 3 frames discarded by this FxPort."
  ::= { fcFxPortC3AccountingEntry 5 }


  -- The Capability Group - consists of a table describing
  -- information about what each FxPort is inherently capable
  -- of operating or supporting.
  -- A capability may be used, as expressed in its respective
  -- object value in the Configuration group.

  fcFxPortCapTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF FcFxPortCapEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "A table that contains, one entry for each FxPort, the
          capabilities of the port within the Fabric Element."
  ::= { fcFeCapabilities 1 }

  fcFxPortCapEntry OBJECT-TYPE
      SYNTAX      FcFxPortCapEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An entry containing the Cap of a FxPort."
      AUGMENTS { fcFxPortEntry }
  ::= { fcFxPortCapTable 1 }


  FcFxPortCapEntry ::=
      SEQUENCE {
          fcFxPortCapFcphVersionHigh
              FcphVersion,
          fcFxPortCapFcphVersionLow
              FcphVersion,
          fcFxPortCapBbCreditMax
              FcBbCredit,
          fcFxPortCapBbCreditMin
              FcBbCredit,
          fcFxPortCapRxDataFieldSizeMax
              FcRxDataFieldSize,
          fcFxPortCapRxDataFieldSizeMin
              FcRxDataFieldSize,
          fcFxPortCapCos
              FcCosCap,
          fcFxPortCapIntermix



Teow                        Standards Track                    [Page 35]


RFC 2837                 FC Fabric Element MIB                  May 2000


              TruthValue,
          fcFxPortCapStackedConnMode
              FcStackedConnMode,
          fcFxPortCapClass2SeqDeliv
              TruthValue,
          fcFxPortCapClass3SeqDeliv
              TruthValue,
          fcFxPortCapHoldTimeMax
              MicroSeconds,
          fcFxPortCapHoldTimeMin
              MicroSeconds
      }

  fcFxPortCapFcphVersionHigh OBJECT-TYPE
      SYNTAX      FcphVersion
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The highest or most recent version of FC-PH that the FxPort
          is capable of supporting."
  ::= { fcFxPortCapEntry 1 }

  fcFxPortCapFcphVersionLow OBJECT-TYPE
      SYNTAX      FcphVersion
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The lowest or earliest version of FC-PH that the FxPort is
          capable of supporting."
  ::= { fcFxPortCapEntry 2 }

  fcFxPortCapBbCreditMax OBJECT-TYPE
      SYNTAX      FcBbCredit
      UNITS       "buffers"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The maximum number of receive buffers available for holding
          Class 1 connect-request, Class 2 or Class 3 frames from the
          attached NxPort."
  ::= { fcFxPortCapEntry 3 }

  fcFxPortCapBbCreditMin OBJECT-TYPE
      SYNTAX      FcBbCredit
      UNITS       "buffers"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION



Teow                        Standards Track                    [Page 36]


RFC 2837                 FC Fabric Element MIB                  May 2000


         "The minimum number of receive buffers available for holding
          Class 1 connect-request, Class 2 or Class 3 frames from the
          attached NxPort."
  ::= { fcFxPortCapEntry 4 }

  fcFxPortCapRxDataFieldSizeMax OBJECT-TYPE
      SYNTAX      FcRxDataFieldSize
      UNITS       "bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The maximum size in bytes of the Data Field in a frame that
          the FxPort is capable of receiving from its attached
          NxPort."
  ::= { fcFxPortCapEntry 5 }

  fcFxPortCapRxDataFieldSizeMin OBJECT-TYPE
      SYNTAX      FcRxDataFieldSize
      UNITS       "bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The minimum size in bytes of the Data Field in a frame that
          the FxPort is capable of receiving from its attached
          NxPort."
  ::= { fcFxPortCapEntry 6 }

  fcFxPortCapCos OBJECT-TYPE
      SYNTAX      FcCosCap
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A value indicating the set of Classes of Service that the
          FxPort is capable of supporting."
  ::= { fcFxPortCapEntry 7 }

  fcFxPortCapIntermix OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether or not the FxPort is capable of
          supporting the intermixing of Class 2 and Class 3 frames
          during a Class 1 connection. This flag is only valid if the
          port is capable of supporting Class 1 service."
  ::= { fcFxPortCapEntry 8 }

  fcFxPortCapStackedConnMode OBJECT-TYPE



Teow                        Standards Track                    [Page 37]


RFC 2837                 FC Fabric Element MIB                  May 2000


      SYNTAX      FcStackedConnMode
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A value indicating the mode of Stacked Connect request that
          the FxPort is capable of supporting."
  ::= { fcFxPortCapEntry 9 }

  fcFxPortCapClass2SeqDeliv OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether or not the FxPort is capable of
          supporting Class 2 Sequential Delivery."
  ::= { fcFxPortCapEntry 10 }

  fcFxPortCapClass3SeqDeliv OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "A flag indicating whether or not the FxPort is capable of
          supporting Class 3 Sequential Delivery."
  ::= { fcFxPortCapEntry 11 }

  fcFxPortCapHoldTimeMax OBJECT-TYPE
      SYNTAX      MicroSeconds
      UNITS       "microseconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The maximum holding time (in microseconds) that the FxPort
          is capable of supporting."
  ::= { fcFxPortCapEntry 12 }

  fcFxPortCapHoldTimeMin OBJECT-TYPE
      SYNTAX      MicroSeconds
      UNITS       "microseconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The minimum holding time (in microseconds) that the FxPort
          is capable of supporting."
  ::= { fcFxPortCapEntry 13 }

  -- conformance information




Teow                        Standards Track                    [Page 38]


RFC 2837                 FC Fabric Element MIB                  May 2000


  fcFeMIBConformance OBJECT IDENTIFIER  ::= { fcFeMIB 2 }
  fcFeMIBCompliances  OBJECT IDENTIFIER ::= { fcFeMIBConformance 1 }
  fcFeMIBGroups       OBJECT IDENTIFIER ::= { fcFeMIBConformance 2 }

  -- compliance statements
  fcFeMIBMinimumCompliance   MODULE-COMPLIANCE
      STATUS   current
      DESCRIPTION
         "The minimum compliance statement for SNMP entities
          which implement the FIBRE-CHANNEL-FE-MIB."
      MODULE  -- this module
      MANDATORY-GROUPS { fcFeConfigGroup, fcFeStatusGroup,
                         fcFeErrorGroup }

      OBJECT        fcFeFabricName
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFeElementName
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFeModuleName
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortAdminMode
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortPhysAdminStatus
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortPhysRttov
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortBbCreditModel
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."



Teow                        Standards Track                    [Page 39]


RFC 2837                 FC Fabric Element MIB                  May 2000


   ::= { fcFeMIBCompliances 1 }

  fcFeMIBFullCompliance   MODULE-COMPLIANCE
      STATUS   current
      DESCRIPTION
         "The full compliance statement for SNMP entities
          which implement the FIBRE-CHANNEL-FE-MIB."
      MODULE  -- this module
      MANDATORY-GROUPS { fcFeConfigGroup, fcFeStatusGroup,
                         fcFeErrorGroup,  fcFeCapabilitiesGroup }

      GROUP fcFeClass1AccountingGroup
      DESCRIPTION
         "This group is mandatory for all fibre channel fabric
          elements which support class 1 frames."

      GROUP fcFeClass2AccountingGroup
      DESCRIPTION
         "This group is mandatory for all fibre channel fabric
          elements which support class 2 frames."

      GROUP fcFeClass3AccountingGroup
      DESCRIPTION
         "This group is mandatory for all fibre channel fabric
          elements which support class 3 frames."

      OBJECT        fcFeFabricName
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFeElementName
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFeModuleName
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortAdminMode
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortPhysAdminStatus
      MIN-ACCESS    read-only



Teow                        Standards Track                    [Page 40]


RFC 2837                 FC Fabric Element MIB                  May 2000


      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortPhysRttov
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

      OBJECT        fcFxPortBbCreditModel
      MIN-ACCESS    read-only
      DESCRIPTION
         "Write access is not required."

   ::= { fcFeMIBCompliances 2 }

   -- units of conformance
   fcFeConfigGroup  OBJECT-GROUP
      OBJECTS { fcFeFabricName, fcFeElementName, fcFeModuleCapacity,
                fcFeModuleDescr, fcFeModuleObjectID,
                fcFeModuleOperStatus, fcFeModuleLastChange,
                fcFeModuleFxPortCapacity, fcFeModuleName,
                fcFxPortName, fcFxPortFcphVersionHigh,
                fcFxPortFcphVersionLow, fcFxPortBbCredit,
                fcFxPortRxBufSize, fcFxPortRatov, fcFxPortEdtov,
                fcFxPortCosSupported, fcFxPortIntermixSupported,
                fcFxPortStackedConnMode, fcFxPortClass2SeqDeliv,
                fcFxPortClass3SeqDeliv, fcFxPortHoldTime }
      STATUS    current
      DESCRIPTION
         "A collection of objects providing the configuration and service
          parameters of the Fabric Element, the modules, and FxPorts."
   ::= { fcFeMIBGroups 1 }

  fcFeStatusGroup  OBJECT-GROUP
     OBJECTS { fcFxPortID, fcFxPortBbCreditAvailable,
               fcFxPortOperMode, fcFxPortAdminMode,
               fcFxPortPhysAdminStatus, fcFxPortPhysOperStatus,
               fcFxPortPhysLastChange, fcFxPortPhysRttov,
               fcFxPortFcphVersionAgreed, fcFxPortNxPortBbCredit,
               fcFxPortNxPortRxDataFieldSize, fcFxPortCosSuppAgreed,
               fcFxPortIntermixSuppAgreed,
               fcFxPortStackedConnModeAgreed,
               fcFxPortClass2SeqDelivAgreed,
               fcFxPortClass3SeqDelivAgreed,
               fcFxPortNxPortName, fcFxPortConnectedNxPort,
               fcFxPortBbCreditModel }
     STATUS    current
     DESCRIPTION



Teow                        Standards Track                    [Page 41]


RFC 2837                 FC Fabric Element MIB                  May 2000


        "A collection of objects providing the operational status and
         established service parameters for the Fabric Element and the
         attached NxPorts."
   ::= { fcFeMIBGroups 2 }

   fcFeErrorGroup  OBJECT-GROUP
      OBJECTS { fcFxPortLinkFailures, fcFxPortSyncLosses,
                fcFxPortSigLosses, fcFxPortPrimSeqProtoErrors,
                fcFxPortInvalidTxWords, fcFxPortInvalidCrcs,
                fcFxPortDelimiterErrors, fcFxPortAddressIdErrors,
                fcFxPortLinkResetIns, fcFxPortLinkResetOuts,
                fcFxPortOlsIns, fcFxPortOlsOuts }
      STATUS    current
      DESCRIPTION
         "A collection of objects providing various error
          statistics detected by the FxPorts."
   ::= { fcFeMIBGroups 3 }

   fcFeClass1AccountingGroup  OBJECT-GROUP
      OBJECTS { fcFxPortC1InFrames, fcFxPortC1OutFrames,
                fcFxPortC1InOctets, fcFxPortC1OutOctets,
                fcFxPortC1Discards, fcFxPortC1FbsyFrames,
                fcFxPortC1FrjtFrames, fcFxPortC1InConnections,
                fcFxPortC1OutConnections, fcFxPortC1ConnTime
      }
      STATUS    current
      DESCRIPTION
         "A collection of objects providing various class 1
  performance statistics detected by the FxPorts."
   ::= { fcFeMIBGroups 4 }

   fcFeClass2AccountingGroup  OBJECT-GROUP
      OBJECTS { fcFxPortC2InFrames, fcFxPortC2OutFrames,
                fcFxPortC2InOctets, fcFxPortC2OutOctets,
                fcFxPortC2Discards, fcFxPortC2FbsyFrames,
                fcFxPortC2FrjtFrames
      }
      STATUS    current
      DESCRIPTION
         "A collection of objects providing various class 2
  performance statistics detected by the FxPorts."
   ::= { fcFeMIBGroups 5 }

   fcFeClass3AccountingGroup  OBJECT-GROUP
      OBJECTS { fcFxPortC3InFrames, fcFxPortC3OutFrames,
                fcFxPortC3InOctets, fcFxPortC3OutOctets,
                fcFxPortC3Discards
      }



Teow                        Standards Track                    [Page 42]


RFC 2837                 FC Fabric Element MIB                  May 2000


      STATUS    current
      DESCRIPTION
         "A collection of objects providing various class 3
          performance statistics detected by the FxPorts."
   ::= { fcFeMIBGroups 6 }

  fcFeCapabilitiesGroup  OBJECT-GROUP
     OBJECTS { fcFxPortCapFcphVersionHigh, fcFxPortCapFcphVersionLow,
               fcFxPortCapBbCreditMax, fcFxPortCapBbCreditMin,
               fcFxPortCapRxDataFieldSizeMax,
               fcFxPortCapRxDataFieldSizeMin,
               fcFxPortCapCos, fcFxPortCapIntermix,
               fcFxPortCapStackedConnMode, fcFxPortCapClass2SeqDeliv,
               fcFxPortCapClass3SeqDeliv, fcFxPortCapHoldTimeMax,
               fcFxPortCapHoldTimeMin
     }
     STATUS    current
     DESCRIPTION
        "A collection of objects providing the inherent
         capability of each FxPort within the Fabric Element."
   ::= { fcFeMIBGroups 7 }


  END
  -- End of Object Definitions

4. Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write.  Such objects may be
   considered sensitive or vulnerable in some network environments.  The
   support for SET operations in a non-secure environment without proper
   protection can have a negative effect on network operations.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), even then, there is no
   control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model RFC 2574 [12] and the View-based
   Access Control Model RFC 2575 [15] is recommended.








Teow                        Standards Track                    [Page 43]


RFC 2837                 FC Fabric Element MIB                  May 2000


   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/delete) them.

5. Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.

6. Acknowledgements

   The editors would like to thank the following individuals for their
   assistance and constructive comments:

      Juergen Schoenwaelder, Technical University Braunschweig
      Vincent Guan, Brocade        Gavin Bowlby, Gadzoox
      Bent Stoevhase, Brocade      Jeff Meyer, HP
      John Y. Chu, IBM
      Yakov Rekhter, Cisco         Martin Sachs, IBM
      Dan Eisenhauer, IBM          Beth Vanderbeck, IBM
      Carl Zeitler, Compaq         Paul Griffiths, IBM
      KC Chennappan, IBM           Jessie Haug, IBM
      Bob Cornelius, ANCOR         Lansing Sloan, LLNL
      Paul Rupert, LLNL            Rich Taborak, NSerial
      Steve Wilson, Brocade        Jerry Rouse, IBM
      Dal Allan, ENDL              Hubert Huot, IBM
      Venkat Rao, HP               Amir Artsi, RADWAY International Ltd.





Teow                        Standards Track                    [Page 44]


RFC 2837                 FC Fabric Element MIB                  May 2000


7. References

7.1. IETF References

   [1]  Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for
        Describing SNMP Management Frameworks", RFC 2571, April 1999.

   [2]  Rose, M. and K. McCloghrie, "Structure and Identification of
        Management Information for TCP/IP-based Internets", STD 16, RFC
        1155, May 1990.

   [3]  Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
        RFC 1212, March 1991.

   [4]  Rose, M., "A Convention for Defining Traps for use with the
        SNMP", RFC 1215, March 1991.

   [5]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Structure of Management Information
        Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

   [6]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
        RFC 2579, April 1999.

   [7]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Conformance Statements for SMIv2", STD
        58, RFC 2580, April 1999.

   [8]  Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
        Network Management Protocol", STD 15, RFC 1157, May 1990.

   [9]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
        "Introduction to Community-based SNMPv2", RFC 1901, January
        1996.

   [10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport
        Mappings for Version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1906, January 1996.

   [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
        Processing and Dispatching for the Simple Network Management
        Protocol (SNMP)", RFC 2572, April 1999.

   [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
        for version 3 of the Simple Network Management Protocol
        (SNMPv3)", RFC 2574, April 1999.




Teow                        Standards Track                    [Page 45]


RFC 2837                 FC Fabric Element MIB                  May 2000


   [13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
        Operations for Version 2 of the Simple Network Management
        Protocol (SNMPv2)", RFC 1905, January 1996.

   [14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
        2573, April 1999.

   [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
        Control Model (VACM) for the Simple Network Management Protocol
        (SNMP)", RFC 2575, April 1999.

   [16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
        to Version 3 of the Internet-standard Network Management
        Framework", RFC 2570, April 1999.

7.2. Approved ANSI/NCITS References

   [17] Fibre Channel Physical and Signaling Interface (FC-PH), American
        National Standard for Information Systems X3.230:1994, Computer
        and Business Equipment Manufacturers Association, Washington,
        DC.

   [18] Fibre Channel Fabric Generic (FC-FG), American National Standard
        for Information Systems X3.289:1996, Computer and Business
        Equipment Manufacturers Association, Washington, DC.

   [19] Fibre Channel Generic Services (FC-GS), American National
        Standard for Information Systems X3.288:1996, Computer and
        Business Equipment Manufacturers Association, Washington, DC.

   [20] Fibre Channel Arbitrated Loop (FC-AL), American National
        Standard for Information Systems X3.272:1996, Computer and
        Business Equipment Manufacturers Association, Washington, DC.

   [21] Fibre Channel Physical and Signaling Interface-2 (FC-PH-2),
        American National Standard for Information Systems, X3.297:1997,
        Computer and Business Equipment Manufacturers Association,
        Washington, DC.

   [22] Fibre Channel Physical and Signaling Interface-3 (FC-PH-3),
        American National Standard for Information Systems, X3.303:1998,
        Computer and Business Equipment Manufacturers Association,
        Washington, DC.

   [23] Fibre Channel Switch Fabric (FC-SW), American National Standard
        for Information Systems, NCITS 321:1998, Computer and Business
        Equipment Manufacturers Association, Washington, DC.




Teow                        Standards Track                    [Page 46]


RFC 2837                 FC Fabric Element MIB                  May 2000


7.3. ANSI/NCITS References Under Development

   [24] Fibre Channel Arbitrated Loop-2 (FC-AL-2), American National
        Standard for Information Systems, X3T11/1133D Rev 5.2, Computer
        and Business Equipment Manufacturers Association, Washington,
        DC.

8. Editor's Address

   Kha Sin Teow
   Brocade Communications Systems, Inc.
   1901 Guadalupe Parkway,
   San Jose, CA 95131
   U.S.A.

   Phone: +1 408-487-8180
   Email: khasin@Brocade.COM


































Teow                        Standards Track                    [Page 47]


RFC 2837                 FC Fabric Element MIB                  May 2000


9. Full Copyright Statement

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.