[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Errata] [Info page]

PROPOSED STANDARD
Errata Exist
Network Working Group                                         A. Bierman
Request for Comments: 3433                           Cisco Systems, Inc.
Category: Standards Track                                   D. Romascanu
                                                              Avaya Inc.
                                                            K.C. Norseth
                                                      L-3 Communications
                                                           December 2002


               Entity Sensor Management Information Base

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it describes managed objects for extending the Entity
   MIB (RFC 2737) to provide generalized access to information related
   to physical sensors, which are often found in networking equipment
   (such as chassis temperature, fan RPM, power supply voltage).

Table of Contents

   1  The Internet-Standard Management Framework ..................  2
   2  Overview ....................................................  2
      2.1 Terms ...................................................  2
      2.2 Relationship to the Entity MIB ..........................  2
      2.3 Relationship to General Thresholding Mechanisms .........  3
   3  MIB Structure ...............................................  3
   4  Definitions .................................................  4
   5  Intellectual Property ....................................... 13
   6  Acknowledgements ............................................ 14
   7  Normative References ........................................ 14
   8  Informative References ...................................... 14
   9  Security Considerations ..................................... 15
   10 Authors' Addresses .......................................... 16
   11 Full Copyright Statement .................................... 17



Bierman, et. al.            Standards Track                     [Page 1]


RFC 3433                   Entity Sensor MIB               December 2002


1. The Internet-Standard Management Framework

   For a detailed overview of the documents that describe the current
   Internet-Standard Management Framework, please refer to section 7 of
   RFC 3410 [RFC3410].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  MIB objects are generally
   accessed through the Simple Network Management Protocol (SNMP).
   Objects in the MIB are defined using the mechanisms defined in the
   Structure of Management Information (SMI).  This memo specifies a MIB
   module that is compliant to the SMIv2, which is described in STD 58,
   RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
   [RFC2580].

2.  Overview

   There is a need for a standardized way of obtaining information
   related to the physical sensors which are commonly found in
   networking equipment.  Information such as the current value of the
   sensor, the current operational status, and the data units precision
   associated with the sensor, should be represented in a consistent
   manner for any type of sensor.

   Physical sensors are represented in the Entity MIB with
   entPhysicalEntry and an entPhysicalClass value of 'sensor(8)'.  The
   information provided in the ENTITY-SENSOR-MIB module (defined in this
   document) defines a sparse augmentation of the entPhysicalTable, for
   entries which represent physical sensors.

2.1.  Terms

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED",  "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in BCP 14, RFC 2119.
   [RFC2119]

2.2.  Relationship to the Entity MIB

   The MIB objects defined in this document provide a sparse
   augmentation to the entPhysicalTable in the Entity MIB, for entries
   in which the associated entPhysicalClass object is equal to
   'sensor(8)'.  An agent is expected to maintain an entPhySensorEntry
   with the same entPhysicalIndex value for each entPhysicalEntry
   representing a physical sensor.  Therefore, implementation of the
   entityPhysicalGroup is required for agents that implement the Entity
   Sensor MIB.




Bierman, et. al.            Standards Track                     [Page 2]


RFC 3433                   Entity Sensor MIB               December 2002


2.3.  Relationship to General Thresholding Mechanisms

   There are no specialized sensor value thresholding mechanisms defined
   in this MIB module.  Instead, it is recommended that a generalized
   thresholding MIB, such as the mechanisms defined by the Alarm and
   Events groups of the Remote Network Monitoring MIB [RFC2819], be used
   for this purpose.

3.  MIB Structure

   The Entity Sensor MIB contains a single group called the
   entitySensorValueGroup, which allows objects to convey the current
   value and status of a physical sensor.

   The entitySensorValueGroup contains a single table, called the
   entPhySensorTable, which provides a small number of read-only
   objects:

   entPhySensorType
      This object identifies the type of data units associated with the
      sensor value.

   entPhySensorScale
      This object identifies the (power of 10) scaling factor associated
      with the sensor value.

   entPhySensorPrecision
      This object identifies the number of decimal places of precision
      associated with the sensor value.

   entPhySensorValue
      This object identifies the current value of the sensor.

   entPhySensorOperStatus
      This object identifies the current operational status of the
      sensor (as it's known to the agent).

   entPhySensorUnitsDisplay
      This object provides a textual description of the data units
      represented by the entPhySensorType and entPhySensorScale objects.

   entPhySensorValueTimeStamp
      The object identifies the value of sysUpTime at the time the agent
      last updated the information in the entry.  This object is only
      relevant if the agent uses a polling implementation strategy,
      (i.e., the associated entPhySensorValueUpdateRate object is
      greater than zero).




Bierman, et. al.            Standards Track                     [Page 3]


RFC 3433                   Entity Sensor MIB               December 2002


   entPhySensorValueUpdateRate
      This object indicates the nature of the agent implementation of
      the entPhySensorEntry, and contains the (possibly estimated)
      number of milliseconds that elapse between polling updates of the
      information in the associated entry.  The value zero indicates
      that the agent always return current data for the entry (as
      opposed to the data as it was at the last polling interval).

4.  Definitions

ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE,
        Integer32, Unsigned32, mib-2
                FROM SNMPv2-SMI
        MODULE-COMPLIANCE, OBJECT-GROUP
                FROM SNMPv2-CONF
        TEXTUAL-CONVENTION, TimeStamp
                FROM SNMPv2-TC
        entPhysicalIndex, entityPhysicalGroup
                FROM ENTITY-MIB
        SnmpAdminString
                FROM SNMP-FRAMEWORK-MIB;

entitySensorMIB MODULE-IDENTITY
    LAST-UPDATED    "200212160000Z"
    ORGANIZATION    "IETF Entity MIB Working Group"
    CONTACT-INFO
            "        Andy Bierman
                     Cisco Systems, Inc.
                Tel: +1 408-527-3711
             E-mail: abierman@cisco.com
             Postal: 170 West Tasman Drive
                     San Jose, CA USA 95134

                     Dan Romascanu
                     Avaya Inc.
                Tel: +972-3-645-8414
              Email: dromasca@avaya.com
             Postal: Atidim technology Park, Bldg. #3
                     Tel Aviv, Israel, 61131

                     K.C. Norseth
                     L-3 Communications
                Tel: +1 801-594-2809
              Email: kenyon.c.norseth@L-3com.com
             Postal: 640 N. 2200 West.



Bierman, et. al.            Standards Track                     [Page 4]


RFC 3433                   Entity Sensor MIB               December 2002


                     Salt Lake City, Utah 84116-0850

             Send comments to <entmib@ietf.org>
             Mailing list subscription info:
               http://www.ietf.org/mailman/listinfo/entmib "
    DESCRIPTION
            "This module defines Entity MIB extensions for physical
             sensors.

             Copyright (C) The Internet Society (2002). This version
             of this MIB module is part of RFC 3433; see the RFC
             itself for full legal notices."

    REVISION        "200212160000Z"
    DESCRIPTION
            "Initial version of the Entity Sensor MIB module, published
             as RFC 3433."
    ::= { mib-2 99 }

entitySensorObjects              OBJECT IDENTIFIER
     ::= { entitySensorMIB 1 }

-- entitySensorNotifications        OBJECT IDENTIFIER
--     ::= { entitySensorMIB 2 }
entitySensorConformance          OBJECT IDENTIFIER
     ::= { entitySensorMIB 3 }

--
-- Textual Conventions
--

EntitySensorDataType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "An object using this data type represents the Entity Sensor
            measurement data type associated with a physical sensor
            value. The actual data units are determined by examining an
            object of this type together with the associated
            EntitySensorDataScale object.

            An object of this type SHOULD be defined together with
            objects of type EntitySensorDataScale and
            EntitySensorPrecision.  Together, associated objects of
            these three types are used to identify the semantics of an
            object of type EntitySensorValue.






Bierman, et. al.            Standards Track                     [Page 5]


RFC 3433                   Entity Sensor MIB               December 2002


            Valid values are:

               other(1):        a measure other than those listed below
               unknown(2):      unknown measurement, or arbitrary,
                                relative numbers
               voltsAC(3):      electric potential
               voltsDC(4):      electric potential
               amperes(5):      electric current
               watts(6):        power
               hertz(7):        frequency
               celsius(8):      temperature
               percentRH(9):    percent relative humidity
               rpm(10):         shaft revolutions per minute
               cmm(11),:        cubic meters per minute (airflow)
               truthvalue(12):  value takes { true(1), false(2) }

            "
    SYNTAX INTEGER {
        other(1),
        unknown(2),
        voltsAC(3),
        voltsDC(4),
        amperes(5),
        watts(6),
        hertz(7),
        celsius(8),
        percentRH(9),
        rpm(10),
        cmm(11),
        truthvalue(12)
    }

EntitySensorDataScale ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "An object using this data type represents a data scaling
            factor, represented with an International System of Units
            (SI) prefix.  The actual data units are determined by
            examining an object of this type together with the
            associated EntitySensorDataType object.

            An object of this type SHOULD be defined together with
            objects of type EntitySensorDataType and
            EntitySensorPrecision.  Together, associated objects of
            these three types are used to identify the semantics of an
            object of type EntitySensorValue."
    REFERENCE
            "The International System of Units (SI),



Bierman, et. al.            Standards Track                     [Page 6]


RFC 3433                   Entity Sensor MIB               December 2002


            National Institute of Standards and Technology,
            Spec. Publ. 330, August 1991."
    SYNTAX INTEGER {
        yocto(1),   -- 10^-24
        zepto(2),   -- 10^-21
        atto(3),    -- 10^-18
        femto(4),   -- 10^-15
        pico(5),    -- 10^-12
        nano(6),    -- 10^-9
        micro(7),   -- 10^-6
        milli(8),   -- 10^-3
        units(9),   -- 10^0
        kilo(10),   -- 10^3
        mega(11),   -- 10^6
        giga(12),   -- 10^9
        tera(13),   -- 10^12
        exa(14),    -- 10^15
        peta(15),   -- 10^18
        zetta(16),  -- 10^21
        yotta(17)   -- 10^24
    }

EntitySensorPrecision ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "An object using this data type represents a sensor
            precision range.

            An object of this type SHOULD be defined together with
            objects of type EntitySensorDataType and
            EntitySensorDataScale.  Together, associated objects of
            these three types are used to identify the semantics of an
            object of type EntitySensorValue.

            If an object of this type contains a value in the range 1 to
            9, it represents the number of decimal places in the
            fractional part of an associated EntitySensorValue fixed-
            point number.

            If an object of this type contains a value in the range -8
            to -1, it represents the number of accurate digits in the
            associated EntitySensorValue fixed-point number.

            The value zero indicates the associated EntitySensorValue
            object is not a fixed-point number.

            Agent implementors must choose a value for the associated
            EntitySensorPrecision object so that the precision and



Bierman, et. al.            Standards Track                     [Page 7]


RFC 3433                   Entity Sensor MIB               December 2002


            accuracy of the associated EntitySensorValue object is
            correctly indicated.

            For example, a physical entity representing a temperature
            sensor that can measure 0 degrees to 100 degrees C in 0.1
            degree increments, +/- 0.05 degrees, would have an
            EntitySensorPrecision value of '1', an EntitySensorDataScale
            value of 'units(9)', and an EntitySensorValue ranging from
            '0' to '1000'.  The EntitySensorValue would be interpreted
            as 'degrees C * 10'."
    SYNTAX Integer32 (-8..9)

EntitySensorValue ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "An object using this data type represents an Entity Sensor
            value.
            An object of this type SHOULD be defined together with
            objects of type EntitySensorDataType, EntitySensorDataScale
            and EntitySensorPrecision.  Together, associated objects of
            those three types are used to identify the semantics of an
            object of this data type.

            The semantics of an object using this data type are
            determined by the value of the associated
            EntitySensorDataType object.

            If the associated EntitySensorDataType object is equal to
            'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6),
            'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of
            this type MUST contain a fixed point number ranging from
            -999,999,999 to +999,999,999.  The value -1000000000
            indicates an underflow error. The value +1000000000
            indicates an overflow error.  The EntitySensorPrecision
            indicates how many fractional digits are represented in the
            associated EntitySensorValue object.

            If the associated EntitySensorDataType object is equal to
            'percentRH(9)', then an object of this type MUST contain a
            number ranging from 0 to 100.

            If the associated EntitySensorDataType object is equal to
            'rpm(10)', then an object of this type MUST contain a number
            ranging from -999,999,999 to +999,999,999.

            If the associated EntitySensorDataType object is equal to
            'truthvalue(12)', then an object of this type MUST contain
            either the value 'true(1)' or the value 'false(2)'.



Bierman, et. al.            Standards Track                     [Page 8]


RFC 3433                   Entity Sensor MIB               December 2002


            If the associated EntitySensorDataType object is equal to
            'other(1)' or unknown(2)', then an object of this type MUST
            contain a number ranging from -1000000000 to 1000000000."
    SYNTAX Integer32 (-1000000000..1000000000)

EntitySensorStatus ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "An object using this data type represents the operational
            status of a physical sensor.

            The value 'ok(1)' indicates that the agent can obtain the
            sensor value.

            The value 'unavailable(2)' indicates that the agent
            presently cannot obtain the sensor value.

            The value 'nonoperational(3)' indicates that the agent
            believes the sensor is broken.  The sensor could have a hard
            failure (disconnected wire), or a soft failure such as out-
            of-range, jittery, or wildly fluctuating readings."
    SYNTAX INTEGER {
        ok(1),
        unavailable(2),
        nonoperational(3)
    }

--
-- Entity Sensor Table
--

entPhySensorTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EntPhySensorEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
            "This table contains one row per physical sensor represented
            by an associated row in the entPhysicalTable."
    ::= { entitySensorObjects 1 }

entPhySensorEntry OBJECT-TYPE
    SYNTAX        EntPhySensorEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
            "Information about a particular physical sensor.





Bierman, et. al.            Standards Track                     [Page 9]


RFC 3433                   Entity Sensor MIB               December 2002


            An entry in this table describes the present reading of a
            sensor, the measurement units and scale, and sensor
            operational status.

            Entries are created in this table by the agent.  An entry
            for each physical sensor SHOULD be created at the same time
            as the associated entPhysicalEntry.  An entry SHOULD be
            destroyed if the associated entPhysicalEntry is destroyed."
    INDEX  { entPhysicalIndex }    -- SPARSE-AUGMENTS
    ::= { entPhySensorTable 1 }

EntPhySensorEntry ::= SEQUENCE {
        entPhySensorType            EntitySensorDataType,
        entPhySensorScale           EntitySensorDataScale,
        entPhySensorPrecision       EntitySensorPrecision,
        entPhySensorValue           EntitySensorValue,
        entPhySensorOperStatus      EntitySensorStatus,
        entPhySensorUnitsDisplay    SnmpAdminString,
        entPhySensorValueTimeStamp  TimeStamp,
        entPhySensorValueUpdateRate Unsigned32
}

entPhySensorType OBJECT-TYPE
    SYNTAX        EntitySensorDataType
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "The type of data returned by the associated
            entPhySensorValue object.

            This object SHOULD be set by the agent during entry
            creation, and the value SHOULD NOT change during operation."
    ::= { entPhySensorEntry 1 }

entPhySensorScale OBJECT-TYPE
    SYNTAX        EntitySensorDataScale
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "The exponent to apply to values returned by the associated
            entPhySensorValue object.

            This object SHOULD be set by the agent during entry
            creation, and the value SHOULD NOT change during operation."
    ::= { entPhySensorEntry 2 }






Bierman, et. al.            Standards Track                    [Page 10]


RFC 3433                   Entity Sensor MIB               December 2002


entPhySensorPrecision OBJECT-TYPE
    SYNTAX        EntitySensorPrecision
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "The number of decimal places of precision in fixed-point
            sensor values returned by the associated entPhySensorValue
            object.

            This object SHOULD be set to '0' when the associated
            entPhySensorType value is not a fixed-point type: e.g.,
            'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.

            This object SHOULD be set by the agent during entry
            creation, and the value SHOULD NOT change during operation."
    ::= { entPhySensorEntry 3 }

entPhySensorValue OBJECT-TYPE
    SYNTAX        EntitySensorValue
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "The most recent measurement obtained by the agent for this
            sensor.

            To correctly interpret the value of this object, the
            associated entPhySensorType, entPhySensorScale, and
            entPhySensorPrecision objects must also be examined."
    ::= { entPhySensorEntry 4 }

entPhySensorOperStatus OBJECT-TYPE
    SYNTAX        EntitySensorStatus
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "The operational status of the sensor."
    ::= { entPhySensorEntry 5 }

entPhySensorUnitsDisplay OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "A textual description of the data units that should be used
            in the display of entPhySensorValue."
    ::= { entPhySensorEntry 6 }





Bierman, et. al.            Standards Track                    [Page 11]


RFC 3433                   Entity Sensor MIB               December 2002


entPhySensorValueTimeStamp OBJECT-TYPE
    SYNTAX        TimeStamp
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "The value of sysUpTime at the time the status and/or value
            of this sensor was last obtained by the agent."
    ::= { entPhySensorEntry 7 }

entPhySensorValueUpdateRate  OBJECT-TYPE
    SYNTAX        Unsigned32
    UNITS         "milliseconds"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
            "An indication of the frequency that the agent updates the
            associated entPhySensorValue object, representing in
            milliseconds.

            The value zero indicates:

                - the sensor value is updated on demand (e.g.,
                  when polled by the agent for a get-request),
                - the sensor value is updated when the sensor
                  value changes (event-driven),
                - the agent does not know the update rate.

            "
    ::= { entPhySensorEntry 8 }

--
-- Conformance Section
--

entitySensorCompliances OBJECT IDENTIFIER
    ::= { entitySensorConformance 1 }
entitySensorGroups      OBJECT IDENTIFIER
    ::= { entitySensorConformance 2 }

entitySensorCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "Describes the requirements for conformance to the Entity
            Sensor MIB module."
    MODULE  -- this module
        MANDATORY-GROUPS { entitySensorValueGroup }





Bierman, et. al.            Standards Track                    [Page 12]


RFC 3433                   Entity Sensor MIB               December 2002


    MODULE ENTITY-MIB
        MANDATORY-GROUPS { entityPhysicalGroup }

    ::= { entitySensorCompliances 1 }

-- Object Groups

entitySensorValueGroup OBJECT-GROUP
    OBJECTS {
             entPhySensorType,
             entPhySensorScale,
             entPhySensorPrecision,
             entPhySensorValue,
             entPhySensorOperStatus,
             entPhySensorUnitsDisplay,
             entPhySensorValueTimeStamp,
             entPhySensorValueUpdateRate
    }
    STATUS  current
    DESCRIPTION
            "A collection of objects representing physical entity sensor
            information."
    ::= { entitySensorGroups 1 }

END

5.  Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.




Bierman, et. al.            Standards Track                    [Page 13]


RFC 3433                   Entity Sensor MIB               December 2002


6.  Acknowledgements

   This memo is a product of the Entity MIB working group.  It is based
   on an existing proprietary MIB module written by Cliff Sojourner.

7.  Normative References

   [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
             Rose, M. and S. Waldbusser, "Structure of Management
             Information Version 2 (SMIv2)", STD 58, RFC 2578, April
             1999.

   [RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
             Rose, M., and S. Waldbusser, "Textual Conventions for
             SMIv2",  STD 58, RFC 2579, April 1999.

   [RFC2580] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
             Rose, M. and S. Waldbusser, "Conformance Statements for
             SMIv2",  STD 58, RFC 2580, April 1999.

   [RFC2737] McCloghrie, K. and A. Bierman, "Entity MIB (Version 2)",
             RFC 2737, December 1999.

   [RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model
             (USM) for version 3 of the Simple Network Management
             Protocol (SNMPv3)", STD 62, RFC 3414, December 2002.

   [RFC3415] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based
             Access Control Model (VACM) for the Simple Network
             Management Protocol (SNMP)", STD 62, RFC 3415, December
             2002.

8.  Informative References

   [RFC2819] Waldbusser, S., "Remote network Monitoring Management
             Information Base", RFC 2819, May 2000.

   [RFC3410] Case, J., Mundy, R., Partain, D. and B. Stewart,
             "Introduction and Applicability Statements for Internet-
             Standard Management Framework", RFC 3410, December 2002.








Bierman, et. al.            Standards Track                    [Page 14]


RFC 3433                   Entity Sensor MIB               December 2002


9.  Security Considerations

   There is one managed object in this MIB that may contain sensitive
   information.  This is:

       entPhySensorValue

   This object may expose the values of particular physical sensors for
   a device.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), there is no control as
   to who on the secure network is allowed to access and GET/SET
   (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementors consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model STD 62, RFC 3414 [RFC3414] and the
   View-based Access Control Model STD 62, RFC 3415 [RFC3415] is
   recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to only the objects, and those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.

























Bierman, et. al.            Standards Track                    [Page 15]


RFC 3433                   Entity Sensor MIB               December 2002


10.  Authors' Addresses

   Andy Bierman
   Cisco Systems, Inc.
   170 West Tasman Drive
   San Jose, CA USA 95134
   Phone: +1 408-527-3711
   EMail: abierman@cisco.com

   Dan Romascanu
   Avaya Inc.
   Atidim Technology Park, Bldg. #3
   Tel Aviv, 61131, Israel
   Phone: +972-3-545-8414
   EMail: dromasca@avaya.com

   K.C. Norseth
   L-3 Communications
   640 N. 2200 West.
   Salt Lake City, Utah 84116-0850
   Phone: +1 801-594-2809
   EMail: kenyon.c.norseth@L-3com.com





























Bierman, et. al.            Standards Track                    [Page 16]


RFC 3433                   Entity Sensor MIB               December 2002


11.  Full Copyright Statement

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Bierman, et. al.            Standards Track                    [Page 17]